INSPECTION
Prior to each use, carefully inspect this equipment for indications of wear or deterioration. The inspection should
include, but not be limited to the following:
unit is free from cracks, excessive wear or corrosion.
all screws are in place, fully seated and properly tightened.
all slots and the pocket of the BuckTooth Assembly are free of dirt, debris and ice build up
(excessive build up may cause improper operation of this unit).
tooth and pins slide freely without any binding.
If any evidence of wear / deterioration as outlined or any unusual conditions not outlined above be observed, or
you have reasonable doubt about a particular condition, immediately remove the equipment from service and
notify your Supervisor, Safety Director or contact Buckingham Mfg. (1-800-937-2825) for clarification.
CLEANING
The BuckTooth may be cleaned by using a cotton swab, limited air pressure or dipping it into a container of water
to remove fine particles and any foreign matter which may enter slots and prevent proper function. The exterior
should be dried with a clean cloth. The inside should be air-dried and re-lubricated as needed.
MAINTAINENCE
Lubricate as often as required to maintain smooth operation (no binding) with a lightweight lubricant such as WD-
40
®
. Do not excessively lubricate, wipe away any excess lubricant with a clean dry cloth.
STORAGE
Proper cleaning, maintenance and storage of your equipment will prolong its useful life and contribute toward its
performance. Your equipment should be stored and transported so that it does not come into contact with debris,
moisture, or chemical agents.