LRV-1 lift control valve
1 General, product description
30/86
300-I-9010050-E-28/02.2012
Terminal
Description
Command signals (with setting command input to “Bucher K1..K8”)
1
2
3
4
5
21
22
23
12
12
6a
7
6b
8
K1 Fast UP
K2 Slow UP
K3 Fast DOWN
K4 Slow DOWN
K5 Inspection speed
K6 Speed reduction (auxiliary speed)
K7 Speed reduction (auxiliary speed)
K8 Speed reduction (auxiliary speed)
Ground/reference potential (GND) for command inputs (K1
…
K8)
Ground/reference potential (GND) for command inputs (K1
…
K8)
Common, DOWN solenoid
Output, DOWN solenoid
Common, UP solenoid
Output, UP solenoid
Demand / feedback monitoring
17a
18
17b
Relay output for the monitoring of the demand/feedback deviation (SIU-1) or the
speed in the unlocking zone (SIU-4).
⇒
page25, chapter1.8.1 and table on page70
Connection for feedback cable
9
10
11
12
Stabilised voltage 15V
Feedback signal (input)
Stabilised voltage supply –15V
Ground, Hall sensor (GND)
Emergency power supply
19
12
20
+24V emergency power supply
Ground, emergency power supply (GND)
–24V emergency power supply