MULTIFEEDER Troubleshooting and Maintenance
- 4.2 -
MULTIFEEDER
Troubleshooting on MULTIFEEDER Devices
Faults
Causes
Solutions
The MULTIFEEDER
display is blank
System powered off
Check that the I/O connector is correctly plugged
in and that there is a 24 Vdc power voltage on
pins 1-2.
Check the protection fuse on KTF/PW4 power
supply.
E2
displayed on
MULTIFEEDER display
1) Motor locked
2) Temporary triggering of
internal protections
1) Check if the motor is correctly turning; detach the
feeding wheel to remove possible yarn residuals
preventing the motor from turning correctly
Correctly thread the MULTIFEEDER
device as
shown on page 2.17
2) Turn the electrical supply of device OFF and then
ON again
If you cannot locate the cause of failure,
please contact your BTSR reseller (it could
be necessary to send the device to the
BTSR repair centre).
E3
displayed on
MULTIFEEDER display
1) Presence of yarn residuals
under the loading cell.
2) OFFSET value of
MULTIFEEDER device out of
adjustment
1) Clean the loading cell sensor, using a light air
blow
(max 1 bar)
2) Perform a correct adjustment of the OFFSET
value on MULTIFEEDER device as described on
page 3.15.
ES ES-CONT
displayed on
MULTIFEEDER display
1) Internal protection against
overcurrents
1) Reset the alarm; if the problem persists, contact
your BTSR reseller.
MT-BUS
displayed on
MULTIFEEDER display
1) Supply voltage lower than 15
Vdc
1) Check the supply voltage, if the problem persists,
contact your BTSR reseller.
CURRENT
displayed
on MULTIFEEDER
display
1) The current absorbed by the
device exceeded the maximum
allowed value.
1) Check the usage conditions of the systems.
If you cannot locate the cause of failure,
please contact your BTSR reseller (it could
be necessary to send the device to the
BTSR repair centre).
TE
displayed on
MULTIFEEDER display
1) The temperature of control
board exceeded the maximum
expected value
1) Check the usage conditions of the systems.
If you cannot locate the cause of failure,
please contact your BTSR reseller (it could
be necessary to send the device to the
BTSR repair centre).
ERR CAN
displayed on
MULTIFEEDER device
Poor communication among the
various devices
Check the MULTIFEEDER communication (see
chapter 2)
Check for correct configuration (for instance check
only the Master 1 has been configured)