![Bticino Salvavita Connesso G723SC Manual Download Page 6](http://html1.mh-extra.com/html/bticino/salvavita-connesso-g723sc/salvavita-connesso-g723sc_manual_2825590006.webp)
6/15
ELIOT Kit Salvavita Connesso
Cat. N°: G723SC
4. PREPARATION - CONNECTION
(continued)
On site information displayed by the Salvavita Connesso
(continued)
:
Device handle status
(continued)
:
. Operation sequences
(continued)
:
- In case of an “Unwanted tripping” of the associated device and
during the verification of the state of the electric circuit:
the power handle is down.
the isolating handle is up.
The Salvavita Connesso can be remotely controlled via the
Smartphone app
- If the Salvavita Connesso detects a permanent fault after a
tripping or a too recurrent non-permanent fault (3 faults and 3
remote closing operations in a time of 5 minutes), the isolating
handle goes down
The Salvavita Connesso cannot be anymore remotely controlled
via the Smartphone app
Note: Refer to the § Details for “too recurrent” non-permanent faults”
for all details on recurrent faults
Resetting by the Salvavita Connesso handle:
. The local resetting of the Salvavita Connesso and of the associated
device can be carried out by the Salvavita Connesso handle
(isolating and power handles together)
4. PREPARATION - CONNECTION
(continued)
On site information displayed by the Salvavita Connesso
(continued)
:
Details for “too recurrent” non-permanent faults:
. During its functioning, the Salvavita Connesso memorises the
numbers of faults and consequent numbers of remote/manual resetting
operations.
. When an event occurs, the Salvavita Connesso analyzes the event
and in case of fault (short-circuit or ground fault) it starts the recurring
fault procedure.
. See table for details:
# of faults
Period
Consequence
3
≤ 5 minutes
- Remote resetting is disabled.
- The application shows this state with
the following message:
3
≤ 1 hour
- The application shows this condition
with a message indicating the number
of faults within the time frame and the
indication to check the electrical
installation on site.
- Remote resetting remains enabled.
5
≤ 1 day
7
≤ 7 days
15
≤ 30 days
Selector AUTO / MAN:
. Enables and disables the remote command of the
Salvavita Connesso.
. Possible states:
- AUTO: allows to remotely control the Salvavita
Connesso via the Smartphone app.
- MAN: on-site manual control only by the handle of
the Salvavita Connesso (isolating and power
handles together)
Note: in case of on-site maintenance, to put the selector on MAN is not
enough. The use of a padlock is the only secured way
Technical data sheet: IDP000172EN_01
Updated: -
Created: 08/09/2017
Isolating handle
Power handle
Isolating handle
Power handle
Isolating handle
Power handle