![background image](http://html1.mh-extra.com/html/bticino/my-home/my-home_technical-manual_2825518050.webp)
48
CONFIGURATION
MY HOME - 2 WIRE SOUND SYSTEM
CONFIGURATION
Amplifier addressing mode
Type of command
Amplifiers
Configurator housing
Configurator value
Point - point
A
1 to 9
PL
1 to 9
Room
A
1 to 9
PL
1 to 9
General
A
1 to 9
PL
1 to 9
CONFIGURATION
General description
So that each Sound System device can perform its function correctly, it must
be correctly configured to define:
- the device address in the system (what it is);
- its mode of operation (what it must do).
This operation is performed by inserting configurators differentiated by
number and letter in the device housings.
Legend
2
1
1. configurator housing
2. description of the configurator housings
3. tool to insert the configurator
Address of the local amplifiers (Item L4562)
-
(A) = Room
set of amplifiers belonging to a logical zone (in a home, for example, the
living room, bedroom, etc…)
-
(PF) Sound point
number identification (1 – 9 ) of each amplifier inside the Room (A)
-
(M1 e M2) = mode
housings for special configurations
-
(A) = Room
if correctly configured can control either a single amplifier (configurator 1 – 9)
or a set of amplifiers (AMB configurator) or become a general switching on
point (GEN configurator) of all the amplifiers, even configured with different
rooms.
-
(PF/PL) = Sound point/light point
number identification (1 – 9) of each amplifier inside the Room (A) or if
configured differently can manage the switching on of the all amplifiers on a
whole room (the room concerns the number from 1 – 9 inserted in housing
“A” of the amplifier).
-
(SPE)
for operation in the Sound System must be configured with the number “8”.
Address of the sound sources
-
(S) = Source
Number identification (1 – 4) of the single sound source in the Sound System.
3
To understand the device addressing logic some terms which will occur
frequently in this guide should be defined.
ADDRESSING THE DEVICES
Address of the special controls (Item L4651/2)
Special control addressing mode
Type of command
Special control
Configurator housing
Configurator value
Point - point
A
1 to 9
PL/PF
1 to 9
Room
A
AMB
PL/PF
1 to 9
General
A
GEN
PL/PF