background image

3

ST-00000220-

24/04/2019

K4659

EN

The device can be configured using the MyHOME_Up app with firmware versions after 2.1 and with app versions after 2.2 (for the use see the relevant documentation).
As an alternative, it is also possible to use the MyHOME_Suite configuration software (version after 03.03.73), or physical configurators connected to the appropriate sockets.

2. MyHOME system

When installed in a Lighting Management system, the device can be configured in the following ways:
- Plug & Go: automatic procedure for pairing devices connected to the inputs and outputs. The procedure is activated on powering the device. It is only available for Room Controllers or, 
in the case of other devices, paired with the Room Controllers.
- Push & Learn: procedure for pairing different connected devices or changing the assignments defined automatically in the Plug & Go procedure. For more details, please refer to the 
specific document.
- Software Configuration: using the Virtual Configurator software; for more details, please refer to the specific manual.

1. Lighting Management System

Modification of the parameters using the configuration remote controls

Configuration

Volume coverage

8 m (PIR)

5 m (PIR)

3 m

(PIR)

≈ 6 m 

(PIR)

1,2 m

m

6

4

5

8

Small movements

Large movements

For further configurations use the remote control item BMS04001 – BMS04003,  

see www.legrandoc.com

ON/OFF Auto function (factory setting)

The sensor parameters are defined by 6 configurator sockets and the functions depend on the operating mode:
Local: A = 1 – 9
Light point: PL = 1 – 9
Mode: M = 0 – 4
Sensitivity of the PIR movement sensor: S = 0 – 3
Control timer: T = 0 – 9
Sensitivity of the lights sensor: D = 0 – 5
Warning: the addresses A = 0 and PL = 0 do not exist

3. Physical configuration

• 

BMSO4001

: advanced configuration remote control

• 

BMSO4003

: simplified configuration remote control

When the sensor receives an IR command from a configuration remote control, it
beeps to confirm that the modification has been acquired.
For more information on the parameters please refer to the technical info sheet of the 
remote control BMSO4001.

Return to factory settings:

1st press: Briefly press LEARN, the LED will blink slowly.
2nd press: Press and hold LEARN for 10 seconds until the LED flashes quickly.

PIR flush mounting motion sensor

Summary of Contents for Living Now BMS04001

Page 1: ... threshold 20 to 1275 LUX Positioning the detector Description Voltage 27Vdc Maximum current draw 15 mA Connection between sensor and actuator SCS BUS connector Sensor type PIR movement detector with 180 detection angle and brightness sensor Flush mounted box depth 40 mm Weight 60 g Impact resistance IK04 Penetration of solids and liquids IP20 Time delay 5 sec 59min 59 sec Brightness 20 1275 lux O...

Page 2: ...f is automatic if no movement is detected at the end of the set delay time After switching off the load if any movement is detected within 30 s the load is automatically switched back on retrigger function on At the end of this time interval the load must be switched back on manually Detection mode Set of technologies used for detection Initial set of technologies used for the first detection Hold...

Page 3: ...ecific manual 1 Lighting Management System Modification of the parameters using the configuration remote controls Configuration Volume coverage 8 m PIR 5 m PIR 3 m PIR 6 m PIR 1 2 m m 6 4 5 8 Small movements Large movements For further configurations use the remote control item BMS04001 BMS04003 see www legrandoc com ON OFF Auto function factory setting The sensor parameters are defined by 6 confi...

Page 4: ...tness level depending on the configurator on D For example when the brightness of the natural light increases the sensor reduces the brightness of the light unit controlled For appropriate operation the brightness sensitivity threshold of the sensor must be configuredusingtheDconfigurator Thethresholdvaluecanbemodifiedusingabrightnesscontrol Thenewvalueisthenconfiguredasthenewsensor threshold unti...

Page 5: ...ensesclean Cleanthesurfacewithacloth Donotuse acetone detergentsforremovingtar ortrichloroethylene Maintenanceusingthefollowingproducts Hexane En60669 1 Methylatedspirit Soapywater Dilutedammonia Bleach diluted10 Glassdetergents BUS EN PIR flush mounting motion sensor ...

Reviews: