3
S
M
P
+
DAY 1
1
ON
OFF
1
MAN P3 COPY PRG
Tmin
Tmax
16
20
THERMO P
ELECTRONIC TIMING THERMOSTAT ART. 4477
GENERAL CHARACTERISTICS:
- 4 programs: MAN, P1, P2, P3
- Frost protection ( only with P3 )
- Manual operation
- It is possible to program two different reference temperature values (Tmin and Tmax)
- Continuous indication on the LC-Display og the time , day of the week, the ambient
temperature, the program chosen, and the on or off position of the load.
- Working reserve: 30 days
- Min time interval between two operations: 1 Minute
- Temperature field displayed: 5
°
C
÷
40
°
C
- Adjustable temperature values 7
°
C
÷
35
°
C (with a min interval of one degree)
- Tolerance for the temperature values:
±
0,25
°
C
- Voltage 230V~ - 50 Hz
- Changeover contact 5A cos
ϕ
1; 2 A cos
ϕ
0,5, voltage free
- Max wire cross-sectional area: 2 x 2,5 mm
2
CRONOTERMOSTATO ELECTRONICO ART. 4477
CARACTERISTICAS GENERALES
- 4 tipos de programas: MAN, P1, P2 y P3
- Función anticongelante
- Mando manual
- Posibilidad de programar dos temperaturas de referencia diferentes (Tmin y Tmax)
- Indicación permanente en el cuadrante de cristal líquido de la hora, el día de la semana, de la
temperatura ambiente, del tipo de programa seleccionado y del funcionamiento del aparato
conectado.
- Reserva de carga: 30 días
- Tiempo mínimo entre una intervención programada y la sucesiva:1minuto
- Banda de temperatura indicada en el display: 5
°
C
÷
40
°
C
- Valores de temperatura programables: 7
°
C
÷
35
°
C (con un intervalo mínimo de un grado)
- Precisión en los valores de la temperatura:
±
0,25
°
C
- Tensión de empleo de 230V~ - 50Hz
- Contacto en conmutación libre de tensión: 5 A cos
ϕ
1 - 2A cos
ϕ
0,5
- Sección max. conductores: 2 x 2,5 mm
2
Summary of Contents for Living 4477