DIP SWITCH SETUP
Before installing the camera, set up the DIP switch to configure the camera ID and the communication protocol.
•
DID numbers of cameras are set up with binary numbers. See the examples shown below.
Pin
1
2
3
4
5
6
7
8
Binary Value
1
2
4
8
16
32
64
128
ex: ID = 5
ex: ID = 10
on
off
off
on
on
off
off
on
off
off
off
off
off
off
off
off
•
The camera ID range is “1~255”.
Camera ID must not be “0”!
•
The factory default of the camera ID is “1”.
•
Match the camera ID with the Cam ID setting of your DVR or Controller to control the camera.
•
If you are connecting a single camera to a controller, terminate the camera. When connecting more than one camera
to a single controller, terminate the last camera on the communication line. The last camera means the camera
farthest in cable length from the controller.
•
Note that the total length of the communication cable between a controller and the camera(s) on the same
communication line must be less than 1.2Km.
• Camera ID Setup