Read carefully before use and keep for future reference

Touching the units with wet hands is forbidden
Using liquid cleaners or aerosols is forbidden
Blocking the ventilation openings is forbidden
Modifying the devices is forbidden
Removing protective parts from the devices is forbidden
Installing the units near liquids and powders is forbidden
Installing the units near heat sources is forbidden
Installing the units near harmful gases, metal dusts or similar is forbidden
Fastening the units on unsuitable surfaces is forbidden

Danger of electrical shock

Risk of devices falling because the surface on which they are installed collapses or inappropriate installation
Switch the power supply OFF before any work on the system

Caution: Installation, configuration, starting-up and maintenance must be performed exclusively by 
qualified personnel.
Check that the wall installation has been carried out correctly
Lay out the wires respecting the standards in force
Connect the power supply wires as indicated
Use only the items indicated in the technical specifications for any system expansions

Warnings and consumer rights

Hereby, BTicino S.p.A., declares that the radio equipment type Small entrance panel 374004 is in compliance with Directive 2014/53/EU. 
The full text of the EU declaration of conformity is available at the following internet address: www.bticino.it/red

Remote operation may cause damage to people or property.

Configuration

The device must be configured by software. For software download, installation device documentation and for any 

other information, refer to the website.

www.homesystems-legrandgroup.com

Technical data

Voltage

24 Vdc

Maximum consumption

0.65 A

C NC NO contact output

125 Vac/0.5A, 30Vdc/2A

Max. cable section for clamps

0.8 mm²

Operating temperature

(- 40) – (+ 70) °C

IP degree of protection

54

IK degree of protection

07

Camera resolution

1080 p

Camera viewing field angle

H= 80°; V= 53°

Face recognition distance during daytime

30-80 cm

Face recognition distance at night

30-50 cm

Badge reader Frequency

13.56 MHz

Badge reader transmission power

< 42 dBuA/m @ 10m

1.  LED for the shooting field lighting

2.  Camera

3.  Light sensor

4.  Badge reader for door lock opening

5.  Microphone

6.  Call key

7.  Guard station call key

8.  Loudspeaker

9.  RJ45 Connector 

(*)

10.  Connection clamp

11.  Mounting bracket

12.  Locking screw

13.  Tamper switch

(*) 

 This device does not support standard POE power supplies, 

but only POE power supplies identified with item no. 375002. 

Connect the cat5/5e/6 FTP or cat5/5e/6 UTP cable with ferrite 

supplied to the connector.

2

4

1

8

1

3

5

6

7

S

E

N

S

E

LO

C

K

-

LO

C

K

+

Fi

re L

in

ka

ge

G

N

D

+1

2V

O

P

E

N

G

N

D

RJ45

N

C

C

O

M

N

O

D

C

24

V

12

10 

9

13

10 

11 

GND

Fire Linkage

Door Open

SENSE
LOCK-
LOCK+

Fire Linkage

GND

+12V

OPEN

GND

RJ45

NC

COM

NO

DC24V

Connection clamp

GND

system common ground terminal for RS485 connection

SENSE

door lock status signal input (dry contact)

LOCK-

electric door lock connection and control (12V -  4A impulsive on 3 Ohm maximum)

LOCK+
OPEN – GND

third party access control signal input for door lock opening (+12Vdc pulse)

FIRE Linkage –GND

local door lock release pushbutton connection for firealarm system

+12V 

access control devices power supply

NO

interlocked contact

COM
NC
DC24V

additional power supply clamps (not polarized)