background image

11/09

-01 PC

Alarms No

tifica

tion M

odule

It

em 349416/349417/349419

Ins

tal

la

tion manual

Summary of Contents for 349416

Page 1: ...11 09 01 PC Alarms Notification Module Item 349416 349417 349419 Installation manual ...

Page 2: ......

Page 3: ...S NOTIFICATION MODULE 5 2 1 Front view 5 2 2 Rear view 6 3 INSTALLATION 7 3 1 Installation using the 506E flush mounting box 7 4 CONFIGURATION 8 4 1 Mode selection 8 5 SWITCHING THE SYSTEM ON 11 5 1 Starting up the system 11 5 2 Resetting the device 11 6 CHECKING THAT THE SYSTEM IS WORKING CORRECTLY 12 APPENDIX 14 ...

Page 4: ...ns power supply Therefore when installing the Alarms Notification Module in a location subject to strong atmospheric disturbance thunderstorms suitable protections devices should also be installed on the power line It is also important that the equipment is correctly connected to the earthing system in accordance with IEC norms 1 2 CONTENTS OF PACKAGE The unit package contains The Alarms Notificat...

Page 5: ...cedure resetting of the device and Code Transponder operation hereinafter called P key LED in the present manual 3 PANIC key it generates an emergency call even with the system disarmed 4 Transponder reader it s compatible with all transponders used with the burglar alarm item 348200 01 02 3 04 05 06 10 20 5 key when used in conjunction with the transponder code it enables access to the system s a...

Page 6: ...ermination select ON if the Alarms Notification Module is the last device within the section 4 Terminal block for connection to the BTicino 2 wire digital system BUS 5 Terminal block for connection to a panic or remote assistance pushbutton 6 Local preset tamper for anti tampering device item L4630 2 DESCRIPTION OF THE ALARMS NOTIFICATION MODULE MOD T1 T2 1 2 _ 3 4 5 _ 6 7 8 _ PANIC BUS OFF ON 349...

Page 7: ... its seat rotate 90 and remove it completely Check that there is no damage by the tamper stem area at the bottom of the flush mounting box otherwise replace After completing all connections secure the device to the flush mounting box Ensure that the cables are positioned in such a way that they will not be damaged Use a small pressure to fit the plate on the device 60mm 52mm 60mm 52mm ...

Page 8: ...technical fault alarms gas leak fire and flooding All 8 alarm contacts should be treated as independent zones They can be choked by disabling their channel The PANIC contact which can also be choked is dedicated to the connection with a panic or remote assistance alarm Each apartment can have only one Alarms Notification Module The device configura tion is done using three configurators MOD T1 and...

Page 9: ...e PANIC Emergency call 3 1 2 Burglary alarm 1 and 2 delayed 3 Generic Technical Fault 4 Generic Technical Fault 5 Freezer 6 Flooding 7 GAS leak 8 Fire PANIC Emergency call MOD Configurator it defines the use of the contacts in accordance with the table T1 Configurator it defines the time delay after the alarm is armed T2 Configurator it defines the time delay for the alarm notification to the hans...

Page 10: ...ndicating the apartment number Fixed delay 30 sec 7 With 3 Mode but T1 and T2 indicating the apartment number Fixed delay 30 sec 4 1 2 System without apartment interface D3 CE 3 J 3 J 3 D3 CE 3 J 3 J 3 Apartment 11 Apartment 1 MOD Configurator it defines the use of the contacts in accordance with the table In modes 4 to 7 the delays for zones 1 and 2 Burglary and technical inputs are set to 30 sec...

Page 11: ... go off and the procedure can continue The op eration can be cancelled by pressing any key The P key stays orange but stops flashing Activate all connected contacts open the magnetic contacts cross the IR coverage area simulate technical alarm conditions etc When each input is activated the relevant LED will come on to indicate that is being handled by the device Once all activations have been com...

Page 12: ...cond After the time delay specified in the configuration the alarm notification will be sent to the Handset and to the Switchboard where it will be displayed After sending the notification the acoustic signal will stop the input LED will continue to stay on but flashing will become slow Technical Fault Alarm When the Alarms Notification Module detects the activation of an enabled technical fault i...

Page 13: ...he LED of input 9 will con tinue to stay on but flashing will become slow Anti tamper alarm Generate a tamper alarm by opening the tamper protection The P LED will start flashing slowly 4 Cancelling alarms To remove the visual notification of the alarm press the button of the input that gen erated the alarm To also remove the alarm signal from the Handset and the Switchboard press the o button and...

Page 14: ...Alarms Notification Module 14 APPENDIX TECHNICAL DATA Operating temperature 0 C 40 C Supply voltage 18 to 27 Vdc from SCS BUS MAX absorption 20 mA ...

Page 15: ......

Page 16: ...pA Via Messina 38 20154 Milano Italia www bticino it BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same ...

Reviews: