![background image](http://html.mh-extra.com/html/bticino/313271/313271_instruction-sheet_2825273002.webp)
쎻
24
쎻
1
쎻
3
쎻
4
쎻
13
쎻
2
쎻
22
쎻
1
쎻
1
쎻
1
쎻
4
쎻
5
쎻
6
쎻
3
쎻
4
쎻
5B
쎻
6
쎻
3
쎻
4
쎻
5B
쎻
6
쎻
3
3
4
Testing the speech circuit
Testing the speech circuit
- The entrance panel contains two potentiometers for adjusting the power of the microphone ( ) and loudspeaker ( )
- In case of a whistle (feedback), first reduce the power of the microphone until an acceptable level is reached
Should whistle persist adjust the loudspeaker volume
Fault finding
No speech or call signal:
Check for 12 V DC on terminal 12 +ve and terminal 1 -ve in the entrance panel
No call signal:
Ensure a link is inserted between 9 and 10 in the entrance panel
Nothing Is working:
A short circuit in the wiring causing a thermal fuse to
operate in the power supply. Disconnect from mains and remove short circuit.
Reconnect after aproximately 5 mins
Connection diagram
- DIN enclosure 6 modules
- Input 230 V ~
±
10 % 50-60 Hz 25VA
Connection terminals:
1
0 V DC
12
12 V DC speech and call signal
22
0 V AC lamp
24
12 VAC lock and lamp
Connection terminals:
1
OVDC
3
microphone output
4
speaker input
5
call wire
9
call tone generator output
10
common feed for pushbuttons
12
12 V DC speech circuit and call signal
22
0 V AC for lock and lamp
24
12 V AC for lock and lamp
Spare lamp Cat. No. 820811
1 -
Door lock release pushbutton
2 -
Call signal volume control
3 -
Housings for extra pushbuttons
It may be wall mounted with the screws supplied
Flex cord with 2 RJ connectors
Adjustable electronic call
Amplified electret microphone
Loudspeaker with mylar diaphragm
Connection terminals:
1
0 VD C
3
speaker input
4
microphone output
5
call input
6
0 V lock output
1A not
used
For technical information on codelock
module 332650 please refer to instruction
booklet
Entrance panel
Power supply unit Cat. No. 336000
Hanset Cat. No. 334202
Pushbuttons
module
332650
Voice module
332120
5A
5B
SP
Outdoor station
NB. For press to exit a
door lock
pushbutton must
be connected
to codelock
module terminals 3
and 4
6
22
NB. Ensure links are
inserted between
9 to 10 on voice module
22 on voice module to 1 on keypad
24 on voice module to 2 on keypad
in entrance panel
쎻
12
쎻
24
쎻
22
쎻
1
쎻
12
Power supply and
connector block
Pushbuttons
module
332650
Voice module
332120
5A
5B
For programming information of the
keypad see enclosed instruction booklet
10
22
24
22
24
10
16
9
14
23
6
5A 5B
1 12
4
3
2
Lock release
12V ac
Technical Specifications
90
61
143
. 5
235
10
22
24
22
24
10
16
9
14
23
6
5A 5B
1 12
4
3
1 2 3 4
5 6 7 8
9 10 11 12 13
1 2 3 4
5 6 7 8
9 10 11 12 13
107
139
56
101
216
1
2
3