Testing the speech circuit

Testing the speech circuit

- The entrance panel contains two potentiometers for adjusting the power of the microphone (  ) and loudspeaker (   )
- In case of a whistle (feedback), first reduce the power of the microphone until an acceptable level is reached
Should whistle persist adjust the loudspeaker volume

Fault finding

No speech or call signal:

Check for 12 V DC on terminal 12 +ve and terminal 1 -ve in the entrance panel

No call signal:

Ensure a link is inserted between 9 and 10 in the entrance panel

Nothing Is working:

A short circuit in the wiring causing a thermal fuse to
operate in the power supply. Disconnect from mains and remove short circuit.
Reconnect after aproximately 5 mins

Connection diagram

Technical Specifications

5B

5A

10

24

22

10

5D

5C

5B

5A

22

24

22

24

10

16

9

14

23

6

5A 5B

1 12

4

3

- DIN enclosure 6 modules
- Input 230 V ~  

±

 10 % 50-60 Hz 25VA

Connection terminals:

1

0 V DC

12

12 V DC speech and call signal

22

0 V AC lamp

24

12 VAC lock and lamp

Connection terminals:

1

OVDC

3

microphone output

4

speaker input

5

call wire

9

call tone generator output

10

common feed for pushbuttons

12

12 V DC speech circuit and call signal

22

0 V AC for lock and lamp

24

12 V AC for lock and lamp

Spare lamp Cat. No. 820811

1 -

 Door lock release pushbutton

2 -

 Call signal volume control

3 - 

Housings for extra pushbuttons

It may be wall mounted with the screws supplied
Flex cord with 2 RJ connectors
Adjustable electronic call
Amplified electret microphone
Loudspeaker with mylar diaphragm

Connection terminals:

1

0 VD C

3

speaker input

4

microphone output

5

call input

6

0 V lock output

1A not 

used

Entrance panel

Power supply unit Cat. No. 336000

Hanset Cat. No. 334202

Lock release
12V ac

Pushbuttons

module

332240

5A
5B
5C
5D

Voice module

332120

5A
5B

SP

Outdoor station

NB.  For press to exit a

door lock
pushbutton must
be connected

to voice module

terminals 6 and 22

6

22

NB.  Ensure links are

inserted between
10 - 10
22 - 22
24 - 24
10 - 9
in entrance panel

12

SP = start position of

every module

Call

lines

Additional

call lines

24

22

1

12

5A

5C

5B

5D

Parallel connections

for additional handsets

3,4,5 and 6 way kits

Power supply and

connector block

Pushbuttons

module

332240

5A
5B
5C
5D

Voice module

332120

5A
5B

Connections for up to
3, 4, 5 and 6 way kits

SP

90

61

107

10

24

22

10

5D

5C

5B

5A

22

24

22

24

10

16

9

14

23

6

5A 5B

1 12

4

3

143

. 5

235

139

56

101

216

1

2

3

SP

SP

Reviews: