![BTI Excel Series Operating Manual Download Page 3](http://html.mh-extra.com/html/bti/excel-series/excel-series_operating-manual_2825051003.webp)
Ph: 905.636.9865 Fax: 905.636.9879
Web:
www.bti-chargers.com
3
ELECTRICAL FEATURES
1. System input 115V 60Hz (90-264V universal input use is possible if used outside Canada).
2. Charging parameters insensitive to
10% system voltage variations.
3. Efficiency > 85%.
4. Output ripple at max load below 150mV.
5. Accuracy of power and voltage measurements 2%.
ELECTROMAGNETIC COMPATIBILITY
The tests of electromagnetic compatibility (
EMC
) on these devices were carried out in compliance
with the
CEI EN55014-1+A2(04/98-06/99) and
CEI EN 55014-2(10/98) STANDARD norms, with
the test instructions and conditions as requested by the norms
.
NORM
RESULT
EN 55014-1+A2
COMPLIANT
EN 55014-1
COMPLIANT
EN 61000– 3-2
COMPLIANT
EN 61000– 3-3
COMPLIANT
EN 61000– 4-2
COMPLIANT
EN 61000– 4-4
COMPLIANT
EN 61000– 4-5
COMPLIANT
EN 61000– 4-6
COMPLIANT
EN 61000– 4-11
COMPLIANT
As to the immunity the devices are classified as Category II.
ELECTRICAL APPROVALS
The CBHD1 and CBHD2 charges are approved and labelled by CSA Special Inspections.
Special versions of CBHD1 are available with cULus Listing.