Excel Series 

 
Models CBHD1 and CBHD2 

 

HIGH FREQUENCY ELECTRONIC 
BATTERY CHARGERS 

 
 
 

Attention:  Carefully read this operating manual before using the battery 

charger. 

 

OPERATING MANUAL 

 

GENERAL INFORMATION ABOUT THIS CHARGER 

 

This device is an electronic battery charger with microprocessor control suitable for any wet 
or sealed lead acid battery type when correctly set.  

 

Fully automatic charging with electronic setting; protected against overload, short-circuit and 
reversed polarity. 

 

WARNINGS 

 

Never disconnect the battery while charging: this could cause sparks. 

 

Never use the equipment in the rain, in areas used for washing or in damp areas. 

 

Caution: the gases generated during charging are explosive. Do not smoke in the vicinity of 
the batteries. When working with cables and electrical equipment, avoid open flames and 
sparks. 

  Before starting to charge, make sure the voltage of the equipment suits the voltage of the 

battery, that the charging current suits the capacity of the battery and that the selected 
charging curve (for lead-acid wet batteries or VRLA - 

i.e. gel or agm

 - batteries) is correct for the 

type of battery to be charged. In addition, make sure the rated input voltage of the charger suits 
the available supply voltage and the system is grounded. 

 

Use battery chargers only in well ventilated areas. 

 

Pay attention to any remarks of the battery manufacturer.

 

 

 

Attention:

 Use protective glasses and gloves during battery maintenance. Battery acid 

causes injuries. In case of contact with battery acid, wash the affected parts with fresh water 
and consult a doctor if necessary. 

 

CHARGE STATUS DISPLAY 

CBHD Series chargers have a 3 led charge status and fault indication display. 
 
Initially all leds light on the panel briefly followed by a double red flash or double green flash.  A 
double red flash indicates a setting for wet lead acid batteries.  A double green flash indicates a 
setting for sealed batteries. 
 

 

Make sure the type of batteries to be charged (sealed or wet lead acid batteries) 
matches the setting of the charger.  If it doesn’t, contact your dealer.

  

 
 

Summary of Contents for Excel Series

Page 1: ... equipment suits the voltage of the battery that the charging current suits the capacity of the battery and that the selected charging curve for lead acid wet batteries or VRLA i e gel or agm batteries is correct for the type of battery to be charged In addition make sure the rated input voltage of the charger suits the available supply voltage and the system is grounded Use battery chargers only ...

Page 2: ...harging profiles have a float stage at the end of charge in this case the charger needs to be left connected to the battery pack Troubleshooting PROBLEMS SOLUTIONS AND CHECKS The battery charger leds do not switch on Check that the plug is connected to the mains supply Check the condition of the AC cordset and the AC input cable The yellow led is flashing Battery is not connected or battery is con...

Page 3: ... EMC on these devices were carried out in compliance with the CEI EN55014 1 A2 04 98 06 99 and CEI EN 55014 2 10 98 STANDARD norms with the test instructions and conditions as requested by the norms NORM RESULT EN 55014 1 A2 COMPLIANT EN 55014 1 COMPLIANT EN 61000 3 2 COMPLIANT EN 61000 3 3 COMPLIANT EN 61000 4 2 COMPLIANT EN 61000 4 4 COMPLIANT EN 61000 4 5 COMPLIANT EN 61000 4 6 COMPLIANT EN 610...

Page 4: ...tensité admissibles de recharge de la batterie sont conformes à la tension et à l intensité de recharge du chargeur De même assurez vous que la courbe de recharge sélectionnée batteries plomb acide à électrolyte liquide ou VRLA autre terme pour les batteries scellées qu elles soient de type AGM ou gel est appropriée au type de batterie à recharger De plus assurez vous que la tension d alimentation...

Page 5: ...s allume en continu À la fin du cycle de recharge lorsque la DEL verte est allumée en continu débranchez le chargeur de sa source d alimentation CA et débranchez la batterie du chargeur Certains profils de recharge incluent une étape d entretien de la charge dans ce cas ne débranchez pas le chargeur de son alimentation et ne débranchez par la batterie du chargeur Dépannage PROBLÈMES VÉRIFICATIONS ...

Page 6: ...re 10 3 Efficacité 85 4 Ondulations parasites CA charge nécessitant moins de 150 mV 5 Précision de la mesure de la puissance et de la tension 2 COMPATIBILITÉ ÉLECTROMAGNÉTIQUE Les essais de compatibilité électromagnétique EMC de ces appareils ont été effectués conformément aux normes CEI EN55014 1 A2 04 98 06 99 et CEI EN 55014 2 10 98 NORME RÉSULTAT EN 55014 1 A2 CONFORME EN 55014 1 CONFORME EN 6...

Reviews: