BT Visitor Phone Quick Install Guide 

 

Issued by: North Supply Ltd 

Issue no: BTDE020201/01 
Date: May 2018 

Page 6 of 7 

 

 

In strictest confidence 

Assigning a speed-dial 
memory destination number 

*    1    1    0    +    M (tone) + X (tone) + DN +  # 
Where: M-memory bank: 0, 1, 2 or 3 
X = a digit 1 through 9 
DN = Destination number = Up to 20 digits, 
including *, #, Pause and A-D characters. 

Empty 

Connecting a speed-dial 
destination 

*    1    1    0    +    M (tone) + X (tone) +  # 
Where: M-memory bank: 0, 1, 2 or 3 
X = a digit 1 through 9 

 

 

1.5

 

Telephony Line Configuration 

Function 

Programming Code 

Default Value 

Loop disconnect detection 

*    3    0    0    +    X 
Where: X = 0 Off 
X = 1 On 

1 - On 

Loop disconnect 
detection time (msec) 

*    3    0    1   +    XXXX 
Where: X = time in msec 

1200 msec 

Speaker volume adjustment 

*    3    0    2   +    X 
Where: X = 1-8 

Microphone volume adjustment  *    3    0    3   +    X 

Where: X = 1-9 

Continuous tone detection time  *    3    0    5   +    X 

Where: X = time in sec 

 

 

1.6

 

Administration 

Function 

Programming Code 

Default Value 

Enter to programming mode 

*    9    1    1 

 

Switch door phone to the 
Day/Night operational mode 

*    9    0    1    - Day mode 
*    9    0    2    - Night mode 
Note: Allowed for system operator as well 

Day 

Programming login time 

*    9    0    3    + XXX 
Where: XXX = time in seconds 000-999 

300-5 minutes 

Enable/disable M1/M2/M3 
memories banks 

*    9    0    3    + X + Y 
Where: X  = 1, Speed dialing memories M1 
group 
X = 2, Speed dialing memories M2 group 
X = 3, Speed dialing memories M3 group 
Y = 1 - Enable, Y = 0 - Disable 

Disabled 

Reset device to it’s factory 
default 

*    9    2    0 

 

System operator’s up to 9 digit 
password settings 

*    9    3    0    + PASSWORD 

54321 

Changing the administrator 
programming password 

*    9    4    0    + PASSWORD 
Programming access password must be up to 
nine numeric digits 0-9. Do not use the * or 
# keys. 

12345 

Summary of Contents for Visitor Phone

Page 1: ...In strictest confidence Visitor Phone BT Visitor Phone Quick Install Guide Issue No BTDE02020101 Issue Date May 2018 ...

Page 2: ...Issue no BTDE020201 01 Date May 2018 Page 2 of 7 In strictest confidence Contents Page 1 Applicable model 4 1 1 Connection diagram 4 1 2 Help and assistance 4 1 3 Programming guide 4 1 4 Telephony Operations 5 1 5 Telephony Line Configuration 6 1 6 Administration 6 ...

Page 3: ... Guide Issued by North Supply Ltd Issue no BTDE020201 01 Date May 2018 Page 3 of 7 In strictest confidence Executive summary This document provides guidance to the field engineering communities for on how to install BT Visitor Phone ...

Page 4: ...gramming mode using the adjacent overleaf programming guide The unit is powered using the supplied power supply For help and assistance please call 0116 257 8147 option 2 1 3 Programming guide Function Programming Code Default Value Enter Programming Mode 911 tone Enter Admin Password 12345 12345 BT Visitor Phone Black BT Visitor Phone Silver Screw rubber gasket and metal back plate to the wall us...

Page 5: ...0 1 Prefix Prefix digits 0 9 only To cancel this operation enter 1 0 1 Example Command 101 259 tone allows dialling to destination numbers with first digit 2 5 and 9 Note Parameter don t take effect on Speed Dial memories destination numbers dialling The maximum conversation time sec 1 0 2 XX Where XX seconds 10 99 00 Unlimited 60 seconds Time interval between DTMF digits during outgoing dialing 1...

Page 6: ... X Where X 1 8 6 Microphone volume adjustment 3 0 3 X Where X 1 9 6 Continuous tone detection time 3 0 5 X Where X time in sec 1 6 Administration Function Programming Code Default Value Enter to programming mode 9 1 1 Switch door phone to the Day Night operational mode 9 0 1 Day mode 9 0 2 Night mode Note Allowed for system operator as well Day Programming login time 9 0 3 XXX Where XXX time in se...

Page 7: ...Offices worldwide British Telecommunications plc 2017 Registered office 81 Newgate Street London EC1A 7AJ Registered in England No 1800000 ...

Reviews: