BT Visitor Phone Quick Install Guide
Issued by: North Supply Ltd
Issue no: BTDE020201/01
Date: May 2018
Page 6 of 7
In strictest confidence
Assigning a speed-dial
memory destination number
* 1 1 0 + M (tone) + X (tone) + DN + #
Where: M-memory bank: 0, 1, 2 or 3
X = a digit 1 through 9
DN = Destination number = Up to 20 digits,
including *, #, Pause and A-D characters.
Empty
Connecting a speed-dial
destination
* 1 1 0 + M (tone) + X (tone) + #
Where: M-memory bank: 0, 1, 2 or 3
X = a digit 1 through 9
1.5
Telephony Line Configuration
Function
Programming Code
Default Value
Loop disconnect detection
* 3 0 0 + X
Where: X = 0 Off
X = 1 On
1 - On
Loop disconnect
detection time (msec)
* 3 0 1 + XXXX
Where: X = time in msec
1200 msec
Speaker volume adjustment
* 3 0 2 + X
Where: X = 1-8
6
Microphone volume adjustment * 3 0 3 + X
Where: X = 1-9
6
Continuous tone detection time * 3 0 5 + X
Where: X = time in sec
1.6
Administration
Function
Programming Code
Default Value
Enter to programming mode
* 9 1 1
Switch door phone to the
Day/Night operational mode
* 9 0 1 - Day mode
* 9 0 2 - Night mode
Note: Allowed for system operator as well
Day
Programming login time
* 9 0 3 + XXX
Where: XXX = time in seconds 000-999
300-5 minutes
Enable/disable M1/M2/M3
memories banks
* 9 0 3 + X + Y
Where: X = 1, Speed dialing memories M1
group
X = 2, Speed dialing memories M2 group
X = 3, Speed dialing memories M3 group
Y = 1 - Enable, Y = 0 - Disable
Disabled
Reset device to it’s factory
default
* 9 2 0
System operator’s up to 9 digit
password settings
* 9 3 0 + PASSWORD
54321
Changing the administrator
programming password
* 9 4 0 + PASSWORD
Programming access password must be up to
nine numeric digits 0-9. Do not use the * or
# keys.
12345