![BT LWE130 Service Manual Download Page 79](http://html.mh-extra.com/html/bt/lwe130/lwe130_service-manual_2824390079.webp)
Electrical system – 5000
Parameters & adjustments
Order number
Date
Valid from serial number
T-code
226057-040
2005-09-23
914369-
675
© BT Europe AB
Service Manual
LWE130
12- 43
•
If the response of the speed control is not balanced in both travel di-
rections.
•
If the VACC NOT OK error occurs.
•
When [R1] is removed or disturbed or is replaced.
Procedure
To perform calibration of the speed potentiometer use the PROGRAM
VACC function in the hand terminal:
•
Connect the hand terminal. See “Connecting the hand terminal” on
page 27.
•
Select PROGRAM VACC from the menu and press ENTER then
ENTER.
•
Move tiller arm to drive position.
•
Slowly move the speed control [L1] from neutral to full deflection first
in one direction then the other direction.
•
Press OUT followed by ENTER.
The transistor regulator and potentiometer have now been calibrated.
*
MAIN MENU
*
PARAMETER CHANGE
*
MAIN MENU
*
STEER TABLE
SEM-X
V..
24v
75A
00000
*
MAIN MENU
*
PROGRAM VACC
ENTER
ENTER
ROLL
VACC SETTING
0.4 4.7
MIN VACC MAX
0.0 - 0.0
MIN VACC MAX
0.5 4.8
ARE YOU SURE ?
YES = ENTER NO = OUT
OUT
OUT
ENTER
Slowly move the speed control
towards max in both directions
ENTER
OUT
https://www.besttruckmanuals.com/