11
4.5 Power cable with RCD - Test procedure
The heat pump comes with a 4-m power cable that includes an in-line,
30-mA residual-current device (RCD).
Perform the RCD TEST before putting the heat pump in service, before
each use of the product, and when putting it back in service after winter
storage.
Do not use the heat pump if the RCD test has failed.
Contact a qualified electrician to perform a diagnostic
and/or to replace the power cable.
RCD test
RESET
T
TH-10-CF PRCD
10A 230V
30mA
n:
I
~ ~
∆
Indicator light
TEST button
RESET button
1.
Plug in the
RCD
plug to the socket. The heat pump’s indicator light turns
on, along with its display screen.
2.
Press the
TEST
button and you should hear a click. The heat pump’s
indicator light and screen turn off.
3.
Press the
RESET
button. The heat pump’s indicator light and screen turn
back on. If the test is successful, you can use the product.
4. INSTALLATION AND CONNECTION (continued)
Summary of Contents for Hayward Micro
Page 1: ...MANUALE di UTILIZZO Pompa di Calore HAYWARD MICRO www bsvillage com ...
Page 2: ......
Page 28: ...Page laissée blanche intentionnellement ...
Page 29: ...HEAT PUMP FOR ABOVE GROUND POOL Installation Instruction Manual MICRO ISMICRO_RevA ...
Page 54: ...Page intentionally left blank ...
Page 80: ...Página en blanco intencionalmente ...
Page 106: ...Página deixada em branco intencionalmente ...
Page 107: ...WÄRMEPUMPE FÜR FREISTEHENDES BECKEN Bedienungs und Installationsanleitung MICRO ISMICRO_RevA ...
Page 132: ...Seite bewusst leer gelassen ...
Page 133: ...WARMTEPOMP VOOR BOVENGRONDS ZWEMBAD Installatie en bedieningshandleiding MICRO ISMICRO_RevA ...
Page 158: ...Opzettelijk leeg gelaten pagina ...
Page 159: ...POMPA DI CALORE PER PISCINE FUORI TERRA Manuale d uso e di installazione MICRO ISMICRO_RevA ...
Page 184: ...Pagina lasciata intenzionalmente bianca ...
Page 185: ...VARMEPUMPE TIL SVØMMEBASSENG OVER BAKKEN Installerings og brukerveiledning MICRO ISMICRO_RevA ...
Page 210: ...Denne siden er blank med hensikt ...