N-BSSALT V3.0
35 / 57
4.2.1- Warnings
Message:
Causes:
Action required:
"LACK OF SALT"
Lack of salt in the water.
Add salt to the swimming
pool.
Incrustations or objects in
the electrolysis cell causing
lack of current.
Clean the cell.
The electrolysis cell is
worn.
Replace the electrolysis cell
with a new one.
"EXCESS SALT"
Excess salt in the water.
No action required if excess
is not very significant.
Incrustations or objects in
the electrolysis cell causing
excess current.
Clean the cell.
4.2.2- Alarms
NO FLOW
Excess
gas
in
the
electrolysis cell. It may be
because the pump has
shutdown. The gas is
hydrogen gas which is
highly flammable.
The piping should be
drained to eliminate gas or
accumulated water. Check
the pump.
Sensor cable of the cell is
incorrectly connected or
broken.
Check the sensor cable
(white cable)
Cell sensor is dirty.
Clean.
See maintenance.
No water flow
Check the water system
SHORT CIRCUIT
The cell is incorrectly
connected.
Check wiring.
Metal body in the cell.
Turn off the equipment and
remove the metal body
from the sheets
OPEN CIRCUIT
Cell
is
incorrectly
connected.
Check the cell connection
and ensure that cables and
connection terminals are in
good condition.