If you use the shaft encoder in an explosive area, you have to install a
terminal box, to which the shaft encoders cables are connected.
The terminal box falls in the machine category 3G and may only be used
in zone 2 and in non-explosive areas.
• Loosen the screws and remove the cover of the terminal box.
• Fix the terminal box with 2x M4 screws.
• Fix the protective earth conductor of the terminal box terminal on
the machine stand.
After cable connection:
• Close the cover of the terminal box by means of the four screws.
For further advice on mounting the terminal box, please see the provided
documentation.
3.5 Control Unit Assembly
The control unit contains the register control hardware and provides the
opportunity of operatig the register control system by means of a touch
screen and a keypad. There are different types of control units. The
following image shows a common type of control unit with climate
control.
All relevant information on your register control systems control
unit type can be found in the customer documentation under MECHA-
NICAL DRAWINGS.