4
| www.bs-battery.com
BATTERY TYPES & CAPACITY
•
Suits all Lead Acid Type Batteries. (Conventional, AGM & Gel).
•
Suits for Lithium (LiFePO4) battery.
•
Battery Capacity:
Charge rate
Battery capacity - charging
Battery capacity - maintaining
2Amp
4-40Ah
4-80Ah
ELECTRICAL PARTS
Delivered with:
•
Input Cord: 150 cm VDE cord with 3PIN plug.
•
Output Cord: with quick connector.
•
Extend Cord: 140 cm cord with battery clips.
ENVIRONMENTAL CHARACTERISTICS
•
Operating Temperature: 0 to 40° C.
•
Storage Temperature: -25 to 85°C.
•
Operating Humidity Range: 0 to 90% RH.
•
Cooling: Natural cooling.
TECHNICAL SPECIFICATIONS
AC input
90~265Vac
Input Frequency
50/60Hz
Rated output
6/12V 2Amp x 3 channels
Suit for battery type
Compatible for Lead acid or LiFePO4 battery
Power Efficiency
>80%
Charging stage
Multiple – 10 stages
Start voltage
2.0V for 6V mode, 8V for 12V mode
Charging voltage
14.4V
De-sulphation I peak
0.2A
De-sulphation V max
16V
Float voltage – Lead acid battery
13.6V
Maintenance voltage – Lead acid batt.
13.0 – 13.8V
IP class
IP22
Dimension L x W X H
20 x 13.3 x 4.3 cm
Voltages for 12V mode, x 1/2 for 6V mode.
OPERATING INSTRUCTIONS
STEP 1 - Pre-charge Check & electrolyte level check
•
Check the Battery Electrolyte level for Lead acid battery (Not required on Sealed & Maintenance Free Batteries). If necessary,
remove the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines.
•
Check the 6/12V Switch on the charger and make sure it’s on the correct voltage.
STEP 2 - Connecting the Bank Charger to your Battery
•
Connect the Red lead from the charger to the positive (+) battery terminal.
•
Connect the Black lead from the charger to the negative (-) battery terminal.
Summary of Contents for BK 20