TECHNICAL SPECIFICATIONS

PARAMETER

CONDITIONS

D65Z

D130Z

D250Z

GAIN 

decibels of gain, 

29 dB

29 dB

29 dB

SENSITIVITY

input volts (RMS) required for nominal power output

0.570 V

0.710 V

.744 V

INPUT IMPEDANCE

Individual channel inputs

Stereo bus inputs

50K Ohms 
20K Ohms

50K Ohms
20K Ohms

50K Ohms
20K Ohms

IMD or THD+noise

max. at nominal power output into 4Ω, 20-20K Hz, 1 ch driven

max. at nominal power output into 4Ω, 20-20K Hz, 8 ch's driven

0.1%
1.0%

0.1%
1.0%

0.1%
1.0%

POWER BANDWIDTH

±0.1dB

20-20K Hz

20-20K Hz

20-20K Hz

NOMINAL OUTPUT 

POWER

1

per ch with all 8 channels driven into 4 Ohm loads

65 Watts 

2

100 Watts 

3

110 Watts 

4

all 8 channels nominal power output @ 1K Hz

695 Watts

1000 Watts

1100 Watts

at 1/8 nominal output power @ 1K Hz.

144 Watts

210 Watts

230 Watts

all inputs open

38 Watts

66 Watts

110 Watts

at idle ~ Standby

5

 

.65 Watts

.65 Watts

.65 Watts

DIMENSIONS

including rubber feet and output connectors (W

H)

48.26

x

40.8

x

11.02 cm

19

x

15.78

x

4.34 in

48.26

x

40.8

x

11.02 cm

19

x

15.78

x

4.34 in

48.26

x

40.8

x

11.02 cm

19

x

15.78

x

4.34 in

WEIGHT

excluding box & packing foam

13.9 Kg

(30.5 Lbs)

18.76 Kg 

(41.4 Lbs)

21.08 Kg 

(46.5 Lbs)

D65Z 

 D130Z 

 D250Z 

 

8 CHANNEL POWER AMPLIFIERS      

300025-3  

BRYSTON LTD., 677 NEAL DRIVE, P.O. BOX 2170, PETERBOROUGH, ONTARIO CANADA  K9J 7Y4 

2011-04-27

1: Output Power:   Nominal output power levels are limited by the amount of current the D130/D250 is allowed to 

draw form a residential branch circuit.  Power output from individual channels or from groups of 
channels can be much higher when only some channels are driven to high power levels. Note 
that each of the two zones, of 4 channels each, has its own power supply.  Therefore, if two or 
more channels are going to be driven harder than the others, it is wise to try to balance the power 
demand across the two zones and thus the two power supplies. 

2: D65: 

 Although the nominal output power per channel of the D65 is 65 Watts per channel with all chan-
nels driven, actual power output can reach 90 Watts  even when all 8 channels are driven.

3: D130: 

 Although the nominal output power per channel of the D130 is 100 Watts per channel with all 
channels driven, actual power output can exceed 140 Watts per channel when only 6 channels are 
driven.

4: D250: 

 Although the nominal output power per channel of the D250 is 110 Watts per channel with all 
channels driven, actual power output can exceed 150 Watts when 6 channels are driven, 230 
Watts per channel when only 4 channels are driven or 290 Watts per channel when 3 channels are 
driven.

5: Standby: 

Unit is plugged in but power switch is deactivated.  

Summary of Contents for D65Z

Page 1: ...OWNER S MANUAL D65Z D130Z D250Z ...

Page 2: ...g defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston Digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of manu facture...

Page 3: ...ch LED Indicators Rear Panel Fuses Power Inlet Remote Power Turn On Connector Page 3 Remote Power Turn On Switch Channel Level Control Channel Direct Inputs Input Selector Switches Output Binding Posts Speaker Connectors External Zone Mutes Page 4 Stereo Bus Inputs AC Power Control External Control Voltage Power Up AC Power Input Technical Specifications Page 5 D65Z D130Z D250Z 8 CHANNEL POWER AMP...

Page 4: ... a cabinet it should have an open front and back Should your installation conditions be constricted then additional forced air cooling may be necessary Any D65 130 250Z channels thermally shutting down during operation indicates insufficient cooling and a remedy must be found for cooling the amplifier Provide a minimum 6 space to the rear of the D65 130 250Z for ventilation and dressing cables to ...

Page 5: ...to be taken to increase airflow across the channels heat sink See installation section on ventilation on page 1 CLIPPING occurs when the channel output level no longer can follow the level increase at the input Over driven input condition When a D65 130 250Z channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced will appear to be ...

Page 6: ...ce 20K Ohms B INPUT SELECTOR SWITCHES These four position slide switches select the input signals for each channel independantly Position Description 1st top Left bus from STEREO BUS INPUTS item 10 2nd sum of left and right STEREO BUS INPUTS item 10 3rd Right bus from STEREO BUS INPUTS item 10 4th bottom direct input from RCA jack C OUTPUT BINDING POSTS The RED binding post is connected to the amp...

Page 7: ...30 250Z The amplifier will now power up when the control voltage is pres ent Immediately following power up the control voltage will appear at the OUT termi nals of the Power Up connector for the control of other equipment Removal of the control voltage causes the D65 130 250Z to turn off and the con trol voltage at the OUT terminals is interrupted NOTE The OUT terminals of the Power Up connector ...

Page 8: ...STON LTD 677 NEAL DRIVE P O BOX 2170 PETERBOROUGH ONTARIO CANADA K9J 7Y4 2011 04 27 1 Output Power Nominal output power levels are limited by the amount of current the D130 D250 is allowed to draw form a residential branch circuit Power output from individual channels or from groups of channels can be much higher when only some channels are driven to high power levels Note that each of the two zon...

Reviews: