Bryston D65Z Owner'S Manual Download Page 5

D65Z 

 D130Z 

 D250Z 

 

8 CHANNEL POWER AMPLIFIERS    

POWER SWITCH

The front panel label "D65", "D130" or "D250" and the on/off symbol   is a switch used to apply or remove A/C line 

power to the D65/130/250Z soft start circuitry. Push the switch and the D65/130/250Z will initiate the start up sequence. 

The switch button remains depressed when circuits are on. Push the switch again the D65/130/250Z will initiate the 

power off sequence.

LED INDICATORS 

Each D65/130/250Z channel has a single multi-colour LED indicator to monitor the following conditions:

● 

Unlit LED: 

 no power

The D65/130/250Z channel LED, when unlit, indicates no A/C mains power is present at the channel. If all channel 

LED indicators are unlit the D65/130/250Z probably needs only to be powered on. A group of 4 LEDs not lighting 

possibly indicates a blown group fuse (there are 2 fuses, one for each group of 4 channels).  When checking fuses 

turn off the unit and unplug the power cord. Use only the specified fuses for your operating voltage. 

See 

FUSES

 section below and 

Replacement Fuses

 label on rear panel.

  ● 

Green LED:  

operating normally

● 

Red LED:  

  -  During Power-Up = 

mute  

  

Each channel normally mutes momentarily during power up and power down sequences.

 

-

 

After Power-Up = 

Thermal Shutdown or Clipping 

THERMAL SHUTDOWN

: The D65/130/250Z channel has thermal shutdown circuitry to prevent damage due to 

over heating. Should thermal shutdown occur, the both stereo channels in the affected zone will mute and the 

channel LEDs will turn red. When the channels have cooled to a safe operating condition the channels will return 

to normal operation. Persistent thermal shutdown indicates steps need to be taken to increase airflow across the 

channels heat sink. (

See installation section on ventilation on page 1)

 

CLIPPING

 occurs when the channel output level no longer can follow the level increase at the input (Over driven 

input condition). When a D65/130/250Z channel is driven into clipping the channel LED will change from green to 

red then back to green when the level is reduced (will appear to be intermittent or flashing red). Momentary clip-

ping can be tolerated, however it indicates that maximum un-distorted power has been surpassed and potential 

speaker damage may result if over load conditions persist. Any amplifier that is constantly operated into clipping 

indicates a more powerful amplifier is needed for that application. Note that a steady red LED may indicate either 

continuous clipping (overload) or thermal shutdown. 

<

 FUSES

External fuses:

   There are two fuse holders located at the rear panel (see illustration on next page). One fuse is 

for channels numbered 1 through 4 which comprise zones 1 & 2. The second fuse is for channels 

5 through 8 which comprise zones 3 & 4.  When checking fuses, power down the unit and dis-

connect the power cord. Use only the specified fuses as indicated on the fuse specification label 

located on the rear panel. 

Internal fuses:

   There are two additional fuses located inside the unit, on the 

SoftStart

 (power inlet) board. These 

fuses have a slightly higher melting point, compared to the external fuses, so they are unlikely to 

blow. If, however, they should need replacing, they should only be replaced by qualified service 

personel. The appropriate fuse values are indicated on a label next to the fuse holders. 

FRONT PANEL

REAR PANEL 

 CONNECTORS 

 SWITCHES

Although a D130Z is shown above, all front panel features are identical for the D65Z, D130Z & D250Z except for the model name on the power switch

Summary of Contents for D65Z

Page 1: ...OWNER S MANUAL D65Z D130Z D250Z ...

Page 2: ...g defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston Digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of manu facture...

Page 3: ...ch LED Indicators Rear Panel Fuses Power Inlet Remote Power Turn On Connector Page 3 Remote Power Turn On Switch Channel Level Control Channel Direct Inputs Input Selector Switches Output Binding Posts Speaker Connectors External Zone Mutes Page 4 Stereo Bus Inputs AC Power Control External Control Voltage Power Up AC Power Input Technical Specifications Page 5 D65Z D130Z D250Z 8 CHANNEL POWER AMP...

Page 4: ... a cabinet it should have an open front and back Should your installation conditions be constricted then additional forced air cooling may be necessary Any D65 130 250Z channels thermally shutting down during operation indicates insufficient cooling and a remedy must be found for cooling the amplifier Provide a minimum 6 space to the rear of the D65 130 250Z for ventilation and dressing cables to ...

Page 5: ...to be taken to increase airflow across the channels heat sink See installation section on ventilation on page 1 CLIPPING occurs when the channel output level no longer can follow the level increase at the input Over driven input condition When a D65 130 250Z channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced will appear to be ...

Page 6: ...ce 20K Ohms B INPUT SELECTOR SWITCHES These four position slide switches select the input signals for each channel independantly Position Description 1st top Left bus from STEREO BUS INPUTS item 10 2nd sum of left and right STEREO BUS INPUTS item 10 3rd Right bus from STEREO BUS INPUTS item 10 4th bottom direct input from RCA jack C OUTPUT BINDING POSTS The RED binding post is connected to the amp...

Page 7: ...30 250Z The amplifier will now power up when the control voltage is pres ent Immediately following power up the control voltage will appear at the OUT termi nals of the Power Up connector for the control of other equipment Removal of the control voltage causes the D65 130 250Z to turn off and the con trol voltage at the OUT terminals is interrupted NOTE The OUT terminals of the Power Up connector ...

Page 8: ...STON LTD 677 NEAL DRIVE P O BOX 2170 PETERBOROUGH ONTARIO CANADA K9J 7Y4 2011 04 27 1 Output Power Nominal output power levels are limited by the amount of current the D130 D250 is allowed to draw form a residential branch circuit Power output from individual channels or from groups of channels can be much higher when only some channels are driven to high power levels Note that each of the two zon...