background image

code: YYWW where YY is the 2 least significant digits of the year and WW is the 

week of the year from 01 to 52) .

4. 

EXTERNAL TURN-ON (REMOTE/LOCAL)

REMOTE: 

To power-up the 9B

SST

2

 using an external control voltage, supply a 4v to 

12v AC or DC control voltage to the ‘IN’ terminals of the 

External Turn-On 

connec-

tor ( 5 ) .  Use insulated 18-22 gauge stranded wire between the source device and 

the 9B

SST

2

 .

Immediately following power up, the control voltage will appear at the ’OUT’ termi-

nals of connector (5) for the control of other equipment .  The removal of the control 

voltage causes the 9B

SST

2

 to turn off and the control voltage at the ‘OUT’ terminals 

is interrupted .  The 9B

SST

2  

draws less than 2mA of current from this control signal .

LOCAL: 

in this position the 9B

SST

2

 will ignore the control voltage and power up 

only by using the front panel power switch .

N.B.

 The Power Switch/Circuit Breaker on the power entry panel at the rear of the 

9B

SST

2

 must be ON for the unit to operate .

5. 

EXTERNAL TURN-ON CONNECTOR

A 4 terminal connector (plug) with screw tightened bare 

wire cage-clamps is provided with each 9B

SST

2

 .  This 

connector is in turn plugged into the 4 pin header in the 

9B

SST2

 to facilitate easier hookup and or removal of a 

remote  control  power  on/off  signal .    Replacement  or 

additional plugs are available from Bryston .

(Part no . CO110A11104) 

D

AT

PL

AT

E

M

od

el

 n

am

re

vi

si

on

Se

ria

l n

um

be

r, 

D

at

co

de

El

ec

tri

ca

l r

at

in

g,

 e

tc

.

EXTERNAL TURN-ON

4~

12

AC

/D

C

O

U

T

IN

LOCAL

REMOTE

POWER SWITCH/CIRCUIT BREAKER

BR

YS

TO

LT

D.

 P

ET

ER

BO

RO

UG

H,

 O

NT

AR

IO

, C

AN

AD

A

O

N

4

5

3

2

1

 MORE INFORMATION

More information about the 9B

SST

2

, including schematic drawings and other technical information, is available at www .

bryston .com . For example:

BRIDGING CHANNELS:

  

For information on bridging 9B channels refer to the document "6B-9B-BRIDGED-HOOKUP .pdf" which can be found on 

www .bryston .com in  TECHNICAL INFORMATION   

  SST2 Amps  

  9B

SST

2

  

  MEMOs

RACK MOUNTING INSTRUCTIONS:

For further information on rack mounting the 9B

SST

2

 refer to the document "9BSST_RACK_MOUNTING_INSTRUC-

TION_SHEET .pdf" which can be found on www .bryston .com in the TECHNICAL INFORMATION section .

POWER OUTPUT: 

 

120 watts per channel into 8 ohms 

 

200 watts per channel into 4 ohms 

GAIN / SENSITIVITY:

  

29dB (1 .1Vin = 120W @ 8 Ohms)

 

 

23dB (2 .2Vin = 120W @ 8 Ohms)

 

 

17dB (4 .4Vin = 120W @ 8 Ohms )

INPUT IMPEDANCE:  

30K ohms (±5%) single ended

 

 

20K ohms (±5%) balanced (each leg)

DISTORTION:  

 

< 0 .005% 20Hz to 20kHz at 120 watts into 8 ohms, 

IMD & THD+NOISE:

 

 < 0 .007% 20Hz to 20kHz at 200 watts into 4 ohms

NOISE:  

 

 

Measured with input shorted (20Hz to 20kHz .)

 

 

 >110dB below rated output 29dB gain (- 73dBu)

 

 

>113dB below rated output 23dB gain (- 76dBu)

 

 

>116dB below rated output 17dB gain (- 79dBu)

SLEW RATE: 

 

>60 volts per microsecond 

POWER BANDWIDTH

: <1 Hz to over 100 kHz 

DAMPING FACTOR:

  Over 500 at 20 Hz, ref . 8 ohms 

DIMENSIONS: 

 

 

 19" Rack mount version:   48 .3 x 13 .3 x 48 .5cm 
(19"w x 5 .25"h x 19 .1"d) with handles 

 

 

 17” version w/o handles:   43 .2 x 13 .3 x 44 .4cm 

(17"w x 5 .25"h x 17 .5"d)  

SHIPPING WEIGHT:

   approx .  34 .5kg (76 lbs) 

POWER CONSUMPTION

& HEAT LOAD:

 

single channel 120W @ 8 ohms:  242 Watts

 

 

5 channels @ 120W @ 8 ohms: 1397 Watts 

 

 

Max . Heat Dissipation 8 ohms:   2720 Btu/Hr .

 

 

single channel 200W @ 4 ohms:  422 Watts

 

 

5 channels @ 200W @ 4 ohms: 2295 Watts

 TECHNICAL SPECIFICATIONS

            9B

SST2

 POWER ENTRY PANEL

Summary of Contents for 9B?SST2

Page 1: ...OWNER S MANUAL 9BSST2 ...

Page 2: ...te control voltage The 9BSST 2 includes soft start power control circuitry to eliminate high inrush currents when AC power is applied SHIPPING BOX PACKING MATERIAL Please keep the original shipping box and all packing material This will ensure the amplifier is protected in future transport In the unlikely event you have a problem and must return it for service you must use the proper packing mater...

Page 3: ...ed to only a few milli Ohms by the Power Conditioner That in turn considerably reduces Voltage drop in the power line on high current surges and quite substantially increases the stability of the power line improving audio and video focus precision and clarity REAR PANEL DETAILS 1 INPUT SELECT SWITCH Each 9BSST 2 channel gives the user the option of switching between either balanced input or singl...

Page 4: ...that may become confused for AC power connectors Cables should be dressed away from input and power cables SPEAKER CONNECTORS BANANA PLUGS offer a quick disconnect option Before inserting a banana plug into the binding post be sure to tighten the post nut to avoid rattling and to provide full insertion of the banana plug Gold plated locking banana plugs are available from Bryston SPADE LUGS provid...

Page 5: ...the channel will return to normal operation Persistent Thermal shutdown indicates steps need to be taken to increase airflow across the channel or channels heat sink Also see installation section on ventilation NOTE In some markets the LED indicators which are normally red green may be red blue instead When red blue LEDs are supplied green is replaced with blue and orange is replaced with magenta ...

Page 6: ...TERBOROUGH ONTARIO CANADA ON 4 5 3 2 1 MORE INFORMATION More information about the 9BSST2 including schematic drawings and other technical information is available at www bryston com For example BRIDGING CHANNELS For information on bridging 9B channels refer to the document 6B 9B BRIDGED HOOKUP pdf which can be found on www bryston com in TECHNICAL INFORMATION SST2 Amps 9BSST2 MEMOs RACK MOUNTING ...

Page 7: ...2A 250V fast acting types e g Littelfuse 217002 For 200 240VAC models replace only with 3 15A 250V time lag fuses e g Littelfuse 2183 15 Before attempting to replace fuses power down amplifier using the Circuit breaker Power switch on the rear Power Entry panel disconnect the power cord Channels are secured by screws on both the top and bottom panels FUSES EXTERNAL DIMENSIONS ...

Page 8: ...from the original date of manufacture The warranty includes parts and labour Bryston Digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of manu facture The warranty includes parts a...

Reviews: