28B-SST Amplifier

5

FRONT PANEL  

(refer to illustration above)

13. ‘28B-SST’ power switch

The front panel label ‘28B-sst’, is a push on push off switch used to apply or remove AC line power to the soft start 

circuitry. ( Note: the rear circuit breaker must be on for the amplifier to power-up)

14. LED Indicators

The 28B-SST has an LED indicator to monitor the following conditions:

 

 

U

nlit

  -  

indicates the amplifier is  turned off.

 

 

R

ed

  -   

indicates the amplifier is muted (as in a power-up sequence)

 

 

G

Reen

  -            indicates the amplifier operation is normal.

 

 

F

lashinG

 R

ed

 -  indicates the amplifier clipping.

 

 

O

RanGe

 - 

indicates thermal shutdown.

 

Power up sequence 

After pushing the '28B-SST POWER' switch, the LED will turn from unlit to red (mute). When the power supply has sta-

bilized the amplifier will come out of mute and the LED will change to green (normal operation).

Unlit LED ( power off )

The 28B-SST LED when unlit indicates no A/C mains power is present and the amplifier probably needs only to be 

powered on or the rear panel circuit breaker is switched off. Should the amplifier not power on when the power switch is 

pushed see the installation instructions.

Clipping  ( flashing red )

Clipping occurs when the channel output level no longer can follow the level increase at the input (Over driven input 

condition). When the 28B-SST is driven into clipping the LED will change from green to red then back to green when 

the level is reduced ( Flashing Red ). Momentary clipping can be tolerated, however it indicates that maximum undis-

torted power has been surpassed and potential speaker damage may result if overload conditions persist. Any amplifier 

that is constantly operated into clipping indicates a more powerful amplifier is needed for that application.

Thermal Shutdown ( orange )

The 28B-SST has thermal shutdown circuitry to prevent damage due to overheating. Should thermal shutdown occur, 

the amplifier will mute, and the LED will turn orange indicating this condition. When the amplifier has cooled to a safe 

operating condition the 28B-SST will return to normal operation. Persistent Thermal shutdown indicates steps need to 

be taken to increase airflow across the heat sink. ( Also see installation section on ventilation ).

13

14

Summary of Contents for 28B SST

Page 1: ...28BSST POWER AMPLIFIER OWNER S MANUAL UPDATED 2006 12 01 ...

Page 2: ...e Input Connector Configuration Setting Input Sensitivity Output Binding Posts Page 3 Power Control Panel Page 4 Master Circuit Breaker AC Power Input Local Auto Switch Front Panel Description Page 5 LED Indicator Power up Sequence LED Indicator Operating Conditions External Dimensions Page 6 Technical Specifications Page 7 Important Safety Instructions Warranty Information Back Cover ...

Page 3: ...thing directly above it Allow 3 5 2u to 5 3u inches of space above and to the sides of this amplifier Do not install directly above other heat generating equipment Should your instillation conditions be constricted then additional forced air cooling may be neces sary Bryston can provide an optional fan package if required Thermal shut down during operation indicates insufficient air flow and a rem...

Page 4: ... same pinout and on the phone jack the TIP will be positive RING is negative and the SLEEVE is ground Use quality 100 shielded cables with gold plated connectors 4 Single Ended Input Un balanced input Imp 50KΩ This input connector accepts standard RCA or Phono connectors Use quality 100 shielded cables with gold plated connectors Balanced input Vs Single ended input The balanced input requires a b...

Page 5: ...ort as practical and should never be terminated with connectors that may become confused for AC power connectors Cables should be dressed away from input and power cables Banana plugs offer a quick disconnect option Before inserting a banana plug into the binding post be sure to tighten the post nut to avoid rattling and to provide full insertion of the banana plug Gold plated locking banana plugs...

Page 6: ...fier from powering up Reasons the applied electrical power is outside the operating range 120v unit connected to 230v Check the electrical ratings label on the rear panel to see if the voltage is correct for your location Otherwise consult your dealer or call the factory 10 11 External control voltage power up Local External switch Interface Connector To power up the SST amplifier using an externa...

Page 7: ...ircuit breaker is switched off Should the amplifier not power on when the power switch is pushed see the installation instructions Clipping flashing red Clipping occurs when the channel output level no longer can follow the level increase at the input Over driven input condition When the 28B SST is driven into clipping the LED will change from green to red then back to green when the level is redu...

Page 8: ...28B SST Amplifier 6 ...

Page 9: ...r Bandwidth 1 Hz to over 100 kHz Damping Factor Over 300 at 20 Hz ref 8 ohms Dimensions maximum dimensions for 19 w version with handles 48 3 x 20 5 x 52 1cm 19w x 8 05 h x 20 525 d See page 6 for more complete details Weight approx 36 4kg 80 lbs Power Consumption Heat Load Power consumption at Idle 215 Watts Max heat dissipation at idle 733 Btu Hr Power consumption 1000W output into 8 ohms 1486 W...

Page 10: ... for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston Digital circuits and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of manu facture The warr...

Reviews: