Bryston 14B3 Owner'S Manual Download Page 8

8

1. Input Select Switch:

Select either Balanced or Single Ended audio 

input.

2. Balanced Audio Input: 

This input connector accepts standard XLR (pin 

1 = Ground, pin 2 = Positive, pin 3 = Negative) or 

1/4” Phone plugs (sleeve = Ground, tip = Positive, 

ring = Negative).  Use quality, 100% shielded 

cables with gold plated connectors.

3. Single Ended Audio Input:

This input connector accepts standard ‘RCA’ or 

‘Phono’ connectors. Use quality, 100% shielded 

cables with gold plated connectors.

4. Gain Select Switch:

The optimum gain setting will depend upon the 

source pre-amp operating level, and or personal 

preference.

The 29dB setting is used when the source is 

single-ended or from a transformer coupled 

balanced source. This is the typical for single 

ended or un-balanced operation. The 29dB 

setting provides the most amplifier gain and 

equates to 100w @ 8 ohms output for a 1V input 

(noise -115 dB). 

The 23dB setting is used when the source 

output is actively balanced. This is the typical 

setting for balanced operation. Or use this 

setting whenver less gain is required.  The 23dB 

setting equates to an output of 100w @ 8 ohms 

for 2V input (noise -119 dB). 

The noise is referenced in dB below rated 

output. Different input configurations result 

in slightly different noise readings. The above 

noise ratings represent minimum readings. 

Actual readings may be better.

5. Channel Level Attenuator (PRO 

ONLY): 

The level control will attenuate the input signal 

level from 0dB through  -14dB.

Rear Panel

WARNING

 

DO NOT CONNECT ANY 

TERMINALS TOGETHER OR 
TO GROUND.
RISK OF HAZARDOUS 

ENERGY. MAKE PROPER 

SPEAKER CONNECTIONS. 

USE CLASS 2 WIRING.

AVERTISSEMENT

NE PAS BRANCHER LES 

BORNES ENSEMBLE OU À LA 

TERRE. RISQUE DE ÉNERGIE 
DANGEREUSE. FAIRE 

CONNECTIONS ENCEINTE 
ADÉQUAT. UTILISATION 

CÂBLAGE DE CLASSE 2.

WARNING

 

DO NOT CONNECT ANY 

TERMINALS TOGETHER OR 
TO GROUND.
RISK OF HAZARDOUS 

ENERGY. MAKE PROPER 

SPEAKER CONNECTIONS. 

USE CLASS 2 WIRING.

AVERTISSEMENT

NE PAS BRANCHER LES 

BORNES ENSEMBLE OU À LA 

TERRE. RISQUE DE ÉNERGIE 
DANGEREUSE. FAIRE 

CONNECTIONS ENCEINTE 
ADÉQUAT. UTILISATION 

CÂBLAGE DE CLASSE 2.

PRO

REG

CAN ICES-3 (B)/NMB-3(B)

_

+

   3   G

+

_

G

This device complies with part 15 of
the FCC Rules. See manual for details.

23dB

GAIN

SINGLE

ENDED

SINGLE

ENDED

SINGLE

ENDED

BALANCED

INPUTS

CAUTION         

ATTENTION

RISK OF ELECTRIC SHOCK - DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR

STATUS

STATUS

See operating manual

for further details.

LOCAL

EXTERNAL 

IN

OUT

12V 

 

POWER UP

600W/8

Ω

600W/8

Ω

CH1 OUTPUT

CH1 OUTPUT

600W/8

Ω

600W/8

Ω

CH

CH

2  

2  

OUTPUT

OUTPUT

BALANCED

29dB

O

N

   

   

 

FF

O

o

I

O

N

   

   

 

FF

O

o

I

PUSH

1

2

3

PUSH

1

2

3

PUSH

1

2

3

PUSH

1

2

3

14B3-Cubed Rear Panel Rev 1

July 7 2015

Garry Faulds

14.00"

made in/fabrique au

Peterborough, Ontario, Canada

3

CIRCUIT BREAKER

POWER SWITCH

CIRCUIT BREAKER

POWER SWITCH

IEC320 POWER INLET

+

G

2

+

G

-

1

3

¼” PHONE or 3-Pin XLR

+

G

2

+

G

-

1

3

¼” PHONE or 3-Pin XLR

BALANCED INPUTS

CAUTION

RISK OF ELECTRIC SHOCK - DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

ATTENTION

Ch2 

Ch1

GAIN

23dB

29dB

INPUT

BALANCED

SINGLE ENDED

SINGLE

ENDED

INPUT

SINGLE

ENDED

INPUT

-14

0dB

LEVEL

See operating manual

for further details.

LOCAL

EXTERNAL 

IN

OUT

12V 

 

POWER-UP 

-14

0dB

LEVEL

1

2

3

11

4

5

6

7

8

9

10

Summary of Contents for 14B3

Page 1: ...14B3 Amplifier Owner s Manual ...

Page 2: ...E BRYSTON LIMITED WARRANTY Bryston analog audio products are warranted to be free from manufacturing defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts exclu...

Page 3: ...on and Usage 4 Welcome 4 Description 4 Features 4 Shipping Box and Packing Material 4 Ventilation 4 Connecting to A C Power 4 Connecting to Loudspeakers 5 Balanced vs Single Ended Input 6 Power Conditioners 6 Front Panel 7 Rear Panel 8 14B3 Specifications 10 Dimensions 11 ...

Page 4: ...e the proper packing material Ship the amplifier only in the original packing material as the unit is not insurable by carriers otherwise Replacement packing materials consisting of a shipping carton with plastic foam inserts is available from Bryston for a small fee Installation and Usage Ventilation Bryston has deliberately chosen to omit fans from our amplifiers in an effort to minimize the noi...

Page 5: ...become damaged Note that copper wire is malleable and may require further tightening after the initial installation To prevent the risk of equipment damage or personal harm use only Class 2 rated loudspeaker wire properly terminated and connected securely to the binding posts Connecting Audio Inputs The Bryston Cubed amplifier can receive analog audio from any preamp or surround processor with vol...

Page 6: ...ision and clarity External Control Voltage To power up the amplifier using an external control voltage supply a 5V to 12V AC or DC control voltage to the IN terminals of connector fig 1 Use paired wire of 22 to 18 gauge between the source device and the Bryston Cubed series amplifier The appropriate mating connector is supplied with each amplifier Set the External Turn On switch to External See 9 ...

Page 7: ...urs when the channel output level no longer can follow the level increase at the input over driven input condition When a channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced Momentary clipping can be tolerated however it indicates that maximum undistorted power has been surpassed and potential speaker damage may result if overl...

Page 8: ...Y TERMINALS TOGETHER OR TO GROUND RISK OF HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTIONS USE CLASS 2 WIRING AVERTISSEMENT NE PAS BRANCHER LES BORNES ENSEMBLE OU À LA TERRE RISQUE DE ÉNERGIE DANGEREUSE FAIRE CONNECTIONS ENCEINTE ADÉQUAT UTILISATION CÂBLAGE DE CLASSE 2 WARNING DO NOT CONNECT ANY TERMINALS TOGETHER OR TO GROUND RISK OF HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTIONS USE CLASS 2 WI...

Page 9: ...the Cubed Series amplifier to operate 8 A C Power Input An IEC 320 C14 power inlet provides for connection of an IEC 320 C13 equipped power cord Before connecting the power cord to the amplifier check that the voltage rating on the data plate or ratings label conforms with your locality With the circuit breaker ON insert the power cord into the Cubed series amplifier then plug the other end to an ...

Page 10: ...ingle Ended Balanced Balanced 7 5kΩ 5kΩ 5kΩ IMD 60Hz 7kHz 4 1 0 005 THD N 20Hz 20kHz 600W 8Ω 0 005 Noise input shorted 22Hz 22kHz SE High 29dB Low 23dB Bal High 29dB Low 23dB 115dB 119dB 116dB 120dB Slew Rate 60V µS Bandwidth 1Hz to 100kHz 3dB Damping 20Hz 8Ω 300 Weight Pounds Kilograms 91 41 3 Power Consumption Watts Standby Idle 600W 8Ω 75W 8Ω 0 5 170 2200 875 Heat Load BTU Hour Idle 600W 8Ω 75W...

Page 11: ...in 18 4 in 16 8 in 7 8 in 7 in 4U 17 in 19 in 19 in Mounting Depth 16 1 in Total Depth 18 1 in 18 4 in 16 8 in Dimensions Minimum recommended clearance for heat dissipation 17 C Series 19 C Series includes front handles 19 PRO Series includes front handles ...

Page 12: ...Bryston Limited 677 Neal Drive Peterborough Ontario K9J 6X7 Canada Phone 705 742 5325 www bryston com 300045 2016 01 19 ...