Outside

 Indication

     Indicates the temperature displayed is from 
           the optional outside sensor.   

Page 21.

Morning

Day

Evening

 & 

Night

 Indication

     Indicates the program time period. 

Page 8-11.

Setup

 Indication

     Indicates the thermostat is in the programming
          mode.  

Page 12.

Fan Operation Indication
     

Fan On

 - indicates constant, continuous fan

          operation.
     When 

Fan On

 is not lit - indicates the fan will

          only operate when necessary to heat or
          to cool.  

Page 7.

Service Filter

 Indication

     

Service Filter

 indicates when the filter should

          be serviced under normal conditions.
          Appears after 0 - 1950 hours of blower
          operation (adjustable).  

Page 15.

Locked

 Indication

     

Locked

 appears after the right combination of

          buttons are pressed,  rendering the buttons
          inoperative. 

Page 22.

Start

 Indication

     Start appears when programming
          timer functions.  

Page 8.

     

Display

Page 4

Summary of Contents for TSTATBBPS701

Page 1: ...manual must be left with the equipment user Heating Cooling Systems USERS INFORMATION MANUAL 67 70 HEAT COOL AUTO o o Am 6 03 68 Su Heat Pump Heat Cool 7 Day Programmable 4 Time Periods per Day Auto Changeover Large Easy To Read Display Thermoglow Backlight Very Easy to Program Programmable Fan No Batteries Required Outdoor Temperature Sensor Available ...

Page 2: ...eriods ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY Page 1 CAUTION Follow Installation Instructions before proceeding SET THERMOSTAT TO MODE OFF PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS 2 3 5 6 8 12 17 23 Residential Light Commercial Systems Carrier Corporation 4 01 TSTATBBPS101 ...

Page 3: ... Cooler or Button Mode Button Heat or Cool Indicator Red Heat Green Cool 67 70 HEAT COOL AUTO o o Am 6 03 68 S SET CLOCK PROGRAM VACATION OUTSIDE FAN MODE Programmable Thermostat FAN PROGRAM VACATION SET CLOCK OUTSIDE 67 70 HEAT COOL AUTO o o Am 6 03 68 Su ...

Page 4: ...GRAM ON indicates the stored program is enabled to run Page 8 Clock with Day of the Week Indicates the current time and day This clock is also used to program the timer periods Page 5 Room Temperature Display Indicates the current room temperature Desired Set Temperature Indicates desired room temperature s Page 7 Display Page 3 1 1 1 1 2 3 4 4 7 6 8 10 11 9 88 88 HEAT COOL OFF AUTO Fan On Program...

Page 5: ...nstant continuous fan operation When Fan On is not lit indicates the fan will only operate when necessary to heat or to cool Page 7 Service Filter Indication Service Filter indicates when the filter should be serviced under normal conditions Appears after 0 1950 hours of blower operation adjustable Page 15 Locked Indication Locked appears after the right combination of buttons are pressed renderin...

Page 6: ...turn to normal operation Quick Start Set the Clock and Go Page 5 This thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming To optimize the installation of this thermostat follow the instructions in the Advanced Setup section 2 Setup S buttons To adjust the clock or Day use Press Setup Am 12 00 i SET CLOCK SET CLOCK MODE ...

Page 7: ...both heating and air conditioning systems are turned off AUTO will automatically select heat or cool based on room temperature demand Program On will activate the stored timer operation Morning Day Evening Night Periods Select Mode Basic Operation Page 6 69 HEAT o Pm 12 00 70 M 72 COOL o Pm 12 00 70 M 69 72 HEAT COOL AUTO o o Pm 12 00 70 M OFF Pm 12 00 70 M 70 73 HEAT COOL ProgramOn o o Pm 12 00 7...

Page 8: ...neously Pressing the Up or Down buttons in Heat or Cool modes will adjust only the heat or cool set temperature Select Desired Temperature Fan Operation Page 7 Basic Operation 69 72 HEAT COOL AUTO o o Pm 12 00 70 M Fan On indicates constant fan operation This feature is active even if the thermostat is set to Off 55 85 HEAT COOL o o Pm 12 00 65 S Fan On Press FAN ...

Page 9: ... start time for Morning Adjust the heating setpoint for Morning Adjust the cooling setpoint for Morning M S 35 99 35 99 M Start Am 7 30 Morning M 74 COOL o Am 7 30 Morning M 72 74 HEAT COOL o o Am 7 30 Morning M Use the back cover Programming Worksheet to help with this section Press PROGRAM Press MODE Press MODE Press MODE Press MODE ...

Page 10: ...ening Adjust the start time for Day Adjust the heating setpoint for Day Adjust the cooling setpoint for Day 35 99 35 99 35 99 Start Am I0 30 Day M Start Pm 5 30 Evening M Day 75 COOL o Am I0 30 M Evening 75 COOL o Pm 5 30 M Day 73 75 HEAT COOL o o Am I0 30 M Press MODE Press MODE Press MODE Press MODE Press MODE ...

Page 11: ...the heating setpoint for Evening Adjust the cooling setpoint for Night Adjust the start time for Night Start Pm I I 30 Night M Night 78 COOL o Pm I I 30 M Pm 5 30 Evening M 73 75 HEAT COOL o o Night 70 78 HEAT COOL o o Am I I 30 M 35 99 35 99 35 99 Press MODE Press MODE Press MODE Press MODE ...

Page 12: ...then pressing mode will copy the previous day s program and then will ask the same copy question again If yes is selected each time this routine will repeat The copy command becomes available after programming the entire previous day If No is selected as in previous steps flashing prompts for input will appear for the 4 time periods for the next day Press MODE Press MODE ...

Page 13: ...elect the day of the week Select residential Heat Pump On or Off On Off Adjust the time of day clock Tip To change hours quickly press and hold the override button in and press the up or down buttons Press Press Press Press Continued MODE MODE MODE MODE Setup AM I2 00 I Setup 2 Mo OFF Setup HP 3 Setup O 4 Select the reversing valve polarity for Heat Pump O or B Step 4 only appears if heat pump is ...

Page 14: ...les per hour limit defeated d1 d defeat 5 min Compressor lockout d d1 2 6 Press Press Press MODE MODE MODE OFF Setup EH 5 Setup Cy 6 8 Setup 8 2 8 6 COOL Setup HEAT 8If 2 7 Select Electric Heat On or Off Step 5 only appears if heat pump is off in step 3 On Off Press Continued MODE Adjust the programmable fan timer 0 60 minutes 0 00 off Press MODE 9 Fan On Setup 0 00 ...

Page 15: ... Adjust the programmable fan stop time step 11 appears only if step 9 is not 0 00 Press FAN Reset the Energy Watch Heat hour counter 0 1999 Select the display back light always On or Off after 8 seconds On Off I0 Fan On Setup On Am 7 00 I I OFF Fan On Setup Pm 9 00 I2 Setup On L I I3 HEAT Setup 0 I4 COOL Setup 0 Press FAN Reset the Energy Watch Cool hour counter 0 1999 ...

Page 16: ...splay will leave the setup screens after 30 seconds Select thermostat operation in degrees Fahrenheit or Centigrade C F Adjust the number of hours the blower will run before the Service Filter icon appears on the display 0 off 0 1950 Press FAN Reset the Service Filter counter This will also remove the Service Filter icon from the display I5 ServiceFilter Setup 0 I6 ServiceFilter Setup 0 I7 Setup F...

Page 17: ... 0 17 Heat Pump Off On Off Reversing Valve polarity O B O Electric Heat Off On Off Deadband or Temperature swing 1 6 1 Forced minimum difference heat cool 0 6 2 Cycles per hour d d1 2 6 6 0 00 0 60 0 00 10 Programmable Fan Start Time 24 hour 7 00 Am 11 Programmable Fan Stop Time 24 hour 9 00 Pm Thermoglow backlight Off On On Energy Watch Heat Timer 0 1999 0 Energy Watch Cool Timer 0 1999 0 Fahrenh...

Page 18: ... HEAT COOL SETPOINT DIFFERENCE The Heat and Cool setpoints will not be allowed to come any closer to each other than the value set in Advanced Setup step 7 on page 13 This minimum difference is enforced during Auto changeover operation and Program On PROGRAMMABLE FAN If the Programmable Fan timer is set to a value other than 0 00 the fan will run for the preprogrammed amount of time The Programmab...

Page 19: ...a feature available to Heat Pump installations To turn on Emergency Heat press in the Fan button While holding the Fan button press Up button for 2 seconds The Cool setpoint display will read EH During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat when there is a demand for heat locking out the 1st stage compressor Exiting Emergency Heat is the same as entering Durin...

Page 20: ...the Mode button While holding the Mode button in press the Up and Down buttons in together The Locked icon will appear on the display Press all 3 for Keypad Lockout To unlock the buttons again press and hold the Mode button While holding the Mode button in press the Up and Down buttons in together The Locked icon will disappear from the display MODE 55 85 HEAT COOL Locked o o Pm 12 00 65 ...

Page 21: ...pied unoccupied unoccupied 8 Press Press MODE MODE VACATION Press Press the Vacation button to exit the Setup screens If no buttons are pressed the display will leave the setup screens after 30 seconds About Advanced Features Operation Page 20 Press the VACATION button to enter the vacation programming setup steps VACATION Select the number of days that the Vacation Schedule will be in effect A va...

Page 22: ...Heat and Cool setpoints will remain spread apart by the amount that they were adjusted prior to entering Auto For example If the Cool setpoint was set to 80 while in the Cool mode and the Heat setpoint was adjusted to 70 while in the Heat mode upon entering the Auto mode the Heat and Cool setpoints would be 80 and 70 Both setpoints would then move up and down together in this example spread by 10 ...

Page 23: ...l operation NOTE CAUTION ON PAGE 1 OUTSIDE SENSOR Optional Accessory When connected to terminals RS 5 RS GND on the back of the thermostat the thermostat will read the temperature from the Outside not control to this sensor it is only to read outside To read the temperature press the Outside button of the thermostat The display will then only show Outside temperature Pressing the Outside button wi...

Page 24: ...ERSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owners manual including filter cle...

Page 25: ...Evening Night Night Copy Fri Sat Copy Tue Wed Copy Thu Fri S U N D A Y Morning Day Evening Night Copy Sat Sun Copy Wed Thu W E N E S D D A Y T U R H S D A Y Morning Morning Day Day Evening Evening Night Night DAY PERIOD HEAT START TIME COOL Copy Mon Tue M O N D A Y T U E S D A Y Morning Morning Day Day Evening Evening Night Night Printed on recycled paper P N 88 307 Rev 1 ...