Installation Instructions

T1--PAC

T1--PHP

LEGACY LINE--RNC

PROGRAMMABLE THERMOSTATS

A07109

Legacy Line--RNC Series Programmable Thermostat

NOTE

: Read the entire instruction manual before starting the

installation

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INSTALLATION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Thermostat Location

1

. . . . . . . . . . . . . . . . . . . . . . . .

Step 2 — Install Thermostat

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Set Thermostat Configuration

2

. . . . . . . . . . . . . . . . .

Step 4 — Understand Thermostat Operation

2

. . . . . . . . . . . . . .

Step 5 — Check Thermostat Operation

3

. . . . . . . . . . . . . . . . . .

WIRING DIAGRAMS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Follow all

local electrical codes during installation. All wiring must conform
to local and national electrical codes. Improper wiring or

installation may damage thermostat.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the equipment and in the instruction

manual, be alert to the potential for personal injury.
Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING

signifies a hazard

which

could

result in personal injury or death.

CAUTION

is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage.

NOTE

is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

INTRODUCTION

There are two Legacy Line--RNC Series programmable thermostat
models, one for AC applications and one for HP applications. Both

are dual powered, operating from either 24VAC or two alkaline
AA batteries. Configuration and program schedules are stored in

non--volatile memory, preserving this information during power
loss and battery removal. Features include simplified 5/2

programming, large backlit display, and modern styling.
The AC model provides one stage of heating and one stage of
cooling.
The HP model provides two stages of heating and one stage of
cooling.

INSTALLATION CONSIDERATIONS

AC Operation

For 24VAC operation, both the R and C wires must be connected

to the 24VAC power source. Batteries are not needed.

Battery Operation

When batteries are used, the common (C) connection is not needed,

saving a wire, and eliminating 24VAC operation. The thermostat

continues to operate in the event of a power failure. Battery life is
one year. A “low battery” reminder tells the homeowner when it is

time to replace the batteries. When connected without the common
wire, the thermostat will not operate without batteries. Continuous

backlighting is not available.

Both Battery and AC Operation

If both batteries and 24VAC operation are used (batteries installed
and the common wire connected), and indefinite clock operation

are provided, the battery will be used only during AC power loss,

extending battery life to nearly its shelf life.
A jumper has to be properly set for backlight operation. J2 should

be set in the “AC” position when the thermostat is operated from
24VAC. J2 should be set in the “BAT” position when the

thermostat is operated from batteries. The thermostat will continue
to operate if J2 is not in the correct position or not connected.

However, the backlight will not operate.

INSTALLATION

Step 1 — Thermostat Location

Thermostat should be mounted:

S

Approximately 5 ft (1.5m) from floor.

S

Close to or in a frequently used room, preferably on an
inside partitioning wall.

S

On a section of wall without pipes or duct work.

Summary of Contents for LEGACY LINE-RNC T1-PAC

Page 1: ...line AA batteries Configuration and program schedules are stored in non volatile memory preserving this information during power loss and battery removal Features include simplified 5 2 programming la...

Page 2: ...ilable an explanation of their function and their factory default settings Not all numbers are used in the Legacy Line RNC Series because not all options are available in this series Configuration Opt...

Page 3: ...l it has 2 stage heat capability In normal operation there is a 15 minute delay between the first and second stages of heat The Y output will energize first then 15 minutes later W is allowed to come...

Page 4: ...Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations E2007 Bryant Heating Cooling Systems 7310 W Morris St I...

Page 5: ...UP or DOWN button the large display shows the current setpoint and the SET TEMP icon is turned on Further presses of the UP or DOWN button adjust the setpoint upward or downward Five seconds after th...

Page 6: ...TIME TEMP button and you are ready to set the new morning temperature To set values for other periods use the PROGRAM button To set values for other days use the DAY button Press HOLD END and you are...

Page 7: ...distributor through a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF...

Page 8: ...at any time specifications or designs without notice and without incurring obligations E2007 Bryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in U S A Edition Date 04 07...

Reviews: