FIELD INSTALLED ACCESSORIES
j
Economizer with D
RY
B
ULB
sensing and barometric
relief
Standard Air Leak Dampers —
f
Models with W7212 controller provides standard
non--diagnostic control. EconoMi$er IV.
f
Models with W7220 controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements. EconoMi$er X.
f
Models with RTU Open controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements. EconoMi$er 2.
j
Economizer with E
NTHALPY
sensing and barometric
relief
Standard Air Leak Dampers —
f
Models with W7212 controller provides standard
non--diagnostic control. EconoMi$er IV.
f
Models with W7220 controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements. EconoMi$er X.
f
Models with RTU Open controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements. EconoMi$er 2.
j
Economizer with D
RY
B
ULB
sensing and barometric
relief
ULTRA LOW LEAK Air Dampers —
f
Models with W7220 controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements, has return, outside
air and relief damper leakage that meets Title 24
(section 140.4 and ASHRAE 90.1) requirements.
EconoMi$er X.
f
Models with RTU Open controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements, has return, outside
air and relief damper leakage that meets Title 24
(section 140.4 and ASHRAE 90.1) requirements.
EconoMi$er 2.
j
Economizer with E
NTHALPY
sensing and barometric
relief
ULTRA LOW LEAK Air Dampers —
f
Models with W7220 controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements, has return, outside
air and relief damper leakage that meets Title 24
(section 140.4 and ASHRAE 90.1) requirements.
EconoMi$er X.
f
Models with RTU Open controller meets California
Title 24 (section 120.2) Fault Detection and
Diagnostic (FDD) requirements, has return, outside
air and relief damper leakage that meets Title 24
(section 140.4 and ASHRAE 90.1) requirements.
EconoMi$er 2.
j
Display Kit for Variable Frequency Drive (VFD),
2--Speed Indoor Fan Motor System. Allows additional
set up and diagnostics of the unit VFD controller. Can
be unit mounted or used with any other compatible
VFD model as a reusable device.
j
Electric heater(s)
j
Single point kit
j
Power exhaust -- centrifugal fan design
j
Two--position motorized outside air damper
j
Manual outside air damper 25%
j
Roofcurb -- 14 inch (356mm) tall
j
Roofcurb -- 24 inch (610mm) tall
j
Thru--the--bottom connections--electrical
j
Condenser hail guard -- louvered style
j
Phase monitor (loss of phase/phase reversal)
j
Winter start kit, down to 25
_
F (--4
_
C)
j
Low ambient head pressure controller,
down to --20
_
F (--29
_
C)
j
Time Guard II compressor anti--cycle protection
j
Four inch filter tracts
j
Return Air smoke detector
j
Supply Air smoke detector
j
Thermostats and Sensors
Economizer Sensors
j
Single Dry bulb control
j
Differential Dry bulb control
j
Single enthalpy control
j
Differential enthalpy control
j
CO
2
-- wall mounted
j
CO
2
-- duct mounted
j
CO
2
-- unit mounted
558J
--
18
--
29H
Summary of Contents for LEGACY 558J
Page 5: ...5 CERTIFIED DIMENSION 558J 18 C13749 558J 18 29H...
Page 6: ...6 CERTIFIED DIMENSION 558J 18 C13750 558J 18 29H...
Page 7: ...7 CERTIFIED DIMENSION 558J 21 25 C13755 558J 18 29H...
Page 8: ...8 CERTIFIED DIMENSION 558J 21 25 C13756 558J 18 29H...
Page 9: ...9 CERTIFIED DIMENSION 558J 29 C13761 558J 18 29H...
Page 10: ...10 CERTIFIED DIMENSION 558J 29 C13762 558J 18 29H...
Page 11: ...11 ROOF CURB DETAILS SIZE 18 C13780 48TC 17 30 V 558J 18 29H...
Page 12: ...12 ROOF CURB DETAILS SIZES 21 25 C13781 48TC 17 30 V 558J 18 29H...
Page 13: ...13 ROOF CURB DETAILS SIZE 29 C13782 48TC 17 30 V 558J 18 29H...