FIELD INSTALLED ACCESSORIES

j

Economizer with D

RY

B

ULB

sensing and barometric

relief

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with D

RY

B

ULB

sensing and barometric

relief

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements.

EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements.

EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements.

EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements.

EconoMi$er 2.

j

Display Kit for Variable Frequency Drive (VFD),

2--Speed Indoor Fan Motor System. Allows additional

set up and diagnostics of the unit VFD controller. Can

be unit mounted or used with any other compatible

VFD model as a reusable device.

j

Electric heater(s)

j

Single point kit

j

Power exhaust -- centrifugal fan design

j

Two--position motorized outside air damper

j

Manual outside air damper 25%

j

Roofcurb -- 14 inch (356mm) tall

j

Roofcurb -- 24 inch (610mm) tall

j

Thru--the--bottom connections--electrical

j

Condenser hail guard -- louvered style

j

Phase monitor (loss of phase/phase reversal)

j

Winter start kit, down to 25

_

F (--4

_

C)

j

Low ambient head pressure controller,

down to --20

_

F (--29

_

C)

j

Time Guard II compressor anti--cycle protection

j

Four inch filter tracts

j

Return Air smoke detector

j

Supply Air smoke detector

j

Thermostats and Sensors

Economizer Sensors

j

Single Dry bulb control

j

Differential Dry bulb control

j

Single enthalpy control

j

Differential enthalpy control

j

CO

2

-- wall mounted

j

CO

2

-- duct mounted

j

CO

2

-- unit mounted

558J

--

18

--

29H

Summary of Contents for LEGACY 558J

Page 1: ...nch disposable return air filters on slide out track S Provisions for thru the bottom power entry capability as standard in an environmentally protected area S Single point electric connections S 24 v...

Page 2: ...ernal Static Pressure in wg Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp Curb Weight lb Heating Heating Capacity Stage 1 Btuh Stage 2 Btuh Heating Capacity Total Btuh Stage 1 kW Stage 2 kW Heati...

Page 3: ...nomizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets California Title 24 section 120 2 Fault Detection and Diagnostic FDD requirements ha...

Page 4: ...d ASHRAE 90 1 requirements EconoMi er 2 j Economizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets California Title 24 section 120 2 Fault...

Page 5: ...5 CERTIFIED DIMENSION 558J 18 C13749 558J 18 29H...

Page 6: ...6 CERTIFIED DIMENSION 558J 18 C13750 558J 18 29H...

Page 7: ...7 CERTIFIED DIMENSION 558J 21 25 C13755 558J 18 29H...

Page 8: ...8 CERTIFIED DIMENSION 558J 21 25 C13756 558J 18 29H...

Page 9: ...9 CERTIFIED DIMENSION 558J 29 C13761 558J 18 29H...

Page 10: ...10 CERTIFIED DIMENSION 558J 29 C13762 558J 18 29H...

Page 11: ...11 ROOF CURB DETAILS SIZE 18 C13780 48TC 17 30 V 558J 18 29H...

Page 12: ...12 ROOF CURB DETAILS SIZES 21 25 C13781 48TC 17 30 V 558J 18 29H...

Page 13: ...13 ROOF CURB DETAILS SIZE 29 C13782 48TC 17 30 V 558J 18 29H...

Page 14: ...ny time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 06 14 Replaces SUB558J 1...

Reviews: