Bryant LEGACY 558J Submittal Data Download Page 3

3

FACTORY--INSTALLED OPTIONS (FIOPs)

j

Economizer with D

RY

B

ULB

sensing and barometric

relief

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with D

RY

B

ULB

sensing and barometric

relief

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er 2.

j

2--Speed Indoor Fan Motor system utilizes a Variable

Frequency Drive (VFD) to automatically adjust the indoor

fan motor for 2 speed indoor fan motor control. Conforms

to ASHRAE 90.1 2010 Standard – section 6.4.3.10.b.

2--speed indoor fan motor is standard on 29 size models.

j

RTU Open multi--protocol controller communicates to

LON, MODBUS, BACNET and Johnson N2 protocols.

j

2 position motorized outdoor air damper

j

25% Manual outdoor air damper

j

Perfect Humidity

t

dehumidification system

j

Non--fused disconnect

j

Powered 115--volt convenience outlet

j

Non--powered 115--volt convenience outlet

j

Medium and High static motor options

j

High static evaporator fan motor

j

Return Air smoke detector

j

Supply Air smoke detector

j

CO

2

sensor

j

Condenser hail guard -- louvered style

j

Special coating protection for evaporator

and condenser coils

j

Hinged access panels

OPTIONAL WARRANTIES

j

Complete Unit Parts only up to 5 years

j

Complete Unit Parts and Labor up to 5 years
Many other optional warranties are available.

See the

Commercial Start--Up and Optional Extended

Warranty Price

price pages for further information.

558J

--

18

--

29H

Summary of Contents for LEGACY 558J

Page 1: ...nch disposable return air filters on slide out track S Provisions for thru the bottom power entry capability as standard in an environmentally protected area S Single point electric connections S 24 v...

Page 2: ...ernal Static Pressure in wg Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp Curb Weight lb Heating Heating Capacity Stage 1 Btuh Stage 2 Btuh Heating Capacity Total Btuh Stage 1 kW Stage 2 kW Heati...

Page 3: ...nomizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets California Title 24 section 120 2 Fault Detection and Diagnostic FDD requirements ha...

Page 4: ...d ASHRAE 90 1 requirements EconoMi er 2 j Economizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets California Title 24 section 120 2 Fault...

Page 5: ...5 CERTIFIED DIMENSION 558J 18 C13749 558J 18 29H...

Page 6: ...6 CERTIFIED DIMENSION 558J 18 C13750 558J 18 29H...

Page 7: ...7 CERTIFIED DIMENSION 558J 21 25 C13755 558J 18 29H...

Page 8: ...8 CERTIFIED DIMENSION 558J 21 25 C13756 558J 18 29H...

Page 9: ...9 CERTIFIED DIMENSION 558J 29 C13761 558J 18 29H...

Page 10: ...10 CERTIFIED DIMENSION 558J 29 C13762 558J 18 29H...

Page 11: ...11 ROOF CURB DETAILS SIZE 18 C13780 48TC 17 30 V 558J 18 29H...

Page 12: ...12 ROOF CURB DETAILS SIZES 21 25 C13781 48TC 17 30 V 558J 18 29H...

Page 13: ...13 ROOF CURB DETAILS SIZE 29 C13782 48TC 17 30 V 558J 18 29H...

Page 14: ...ny time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 06 14 Replaces SUB558J 1...

Reviews: