background image

GAPAB

PERFECT AIR AIR PURIFIER FOR FAN COILS

SIZES 1620, 2020 AND 2420

Installation Instructions

NOTE

:

Read the entire instruction manual before starting the

install.

TABLE OF CONTENTS

PAGE

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . . . .

INSTALLATION

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

6

. . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

9

. . . . . . . . . . . . . . . . .

WARRANTY

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Perfect Air Air Purifier for your

home comfort system! The Perfect Air

Air Purifier is proven to

remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Perfect Air Air Purifier is a

cornerstone of Bryant’s Healthy Home Solutions for providing
healthier, cleaner air in your home.

HOW IT WORKS

The Perfect Air Air Purifier provides extremely high filtration

performance while killing captured contaminants, including

viruses, bacteria, and mold spores. The Perfect Air Air Purifier
treats the entire air--stream through a state of the art, three--stage

process, exclusive to Bryant.
In stage one, the particles are electrically charged by a

precision--point ionization array as they enter the Perfect Air Air

Purifier.
In stage two, the charged particles are electrically attracted to the air

purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current

flow and ion bombardment.
The Perfect Air Air Purifier is CSA certified for shock and

electrical fire hazard only.
La Perfect Air Air Purifier certification CSA vise uniquement les
risques de choc electrique et.

A06367

Fig. 1 -- GAPAB Unit

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury or property
damage. Consult a qualified installer, service agency or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings and cautions

included in literature and attached to the unit. Consult local
building codes and the current edition of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.

Recognize safety information. When you see this symbol

on

the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the

safety--alert symbol.

DANGER

identifies the most serious hazards,

which

will

result in severe personal injury or death.

WARNING

signifies hazards, which

could

result in personal injury or death.

CAUTION

is used to identify unsafe practices, which

may

result

in minor personal injury or product and property damage.

NOTE

is used to highlight suggestions which

will

result in enhanced

installation, reliability, or operation.

Summary of Contents for GAPAB

Page 1: ...La Perfect Air Air Purifier certification CSA vise uniquement les risques de choc electrique et A06367 Fig 1 GAPAB Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or ...

Page 2: ...t recommended and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets Transitions If the return air duct or fan coil openings do not fit the Perfect Air Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 i...

Page 3: ...stem b Remove the existing fan coil filter and discard Excessive sys tem static pressure may result if the Perfect Air Air Purifier is used with other filtration devices c Remove the air purifier cartridge and enhancement module from the Perfect Air Air Purifier cabinet d Position the cabinet between the fan coil and return air duct see Fig 4 and 5 A transition duct may be required NOTE The fan co...

Page 4: ...e power has been removed from the heating and cooling system b Turn the Perfect Air Air Purifier power switch off c Connect the power cord and the flow sensor cord to the power supply connector and the flow sensor connector see Fig 7 and Fig 8 A06414 Fig 7 Flow Sensor Cable Installed A06413 Fig 8 Power Cord Installed NOTE The power cord can be routed through the opposite side of the cabinet Zip ti...

Page 5: ...ranty CAUTION AIR FLOW SENSOR CABLE OR AIR FLOW SENSOR BYPASS PLUG MUST BE CONNECTED TO THE POWER SUPPLY IN ORDER TO ACTIVATE THE AIR PURIFIER NOTICE A06670 Fig 9 Airflow Sensor Bypass Plug Installed TO FAN COIL FIELD POWER CONNECTION FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS IN BAG ATTACHED TO POWER CORD AIR PURIFIER POWER CORD TO FAN COIL FIELD POWER CONNECTION TO L2 FIELD POWER S...

Page 6: ...s obtained when the furnace blower is set for continuous operation on the thermo stat or Perfect Air Control MAINTENANCE The Perfect Air Air Purifier is designed to require minimal maintenance Maintenance is limited to the replacement of the air purification cartridge and inspection brush cleaning of the ionization array Frequency of air purifier cartridge replacement and cleaning of the ionizatio...

Page 7: ...ch bar with enough brush depth to hit front and back tips of the points in the ionization array Use a gentle back and forth brushing motion to clean any small accumulations from the tips of the points If desired use vacuum cleaner with brush attachment to gently vacuum the frame and components of enhancement module Step 8 Reinstall the Safety Screen Step 9 Slide in enhancement module Step 10 Recon...

Page 8: ...Step 3 Confirm that the fan coil blower is operating Step 4 Confirm that 208 230 VAC power is provided Attach power supply connector to the air purifier when the fan coil blower is operating NOTE Even though power is supplied to the Perfect Air Air Purifier it will not turn on unless the airflow sensor senses airflow or the airflow sensor s bypass plug is inserted Step 5 Confirm that the airflow s...

Page 9: ...imum Airflow CFM 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1620 GAPCCCAR2020 GAPCCCAR2420 Initial Pressure Drop in w c at maximum airflow 22 25 22 DIMENSIONS GAPABXBB1620 GAPABXBB2020 GAPABXBB2420 A 18 1 2 22 25 1 2 B 15 1 8 18 5 8 22 1 8 C 13 1 8 13 1 8 13 1 8 D 17 5 8 21 1 8 24 5 8 E 19 3 4 19 3 4 19 3 4 F 22 1 4 22 ...

Page 10: ...10 GAPAB ...

Page 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Page 12: ...TIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defecti...

Reviews: