7
Step 5 —
Slide out the enhancement module assembly and safety
screen.
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when
handling parts.
CAUTION
!
Step 6 —
Slide out the Safety Screen and set aside.
NOTE
: Best cleaning tools: 5 inch handle paint brush with 2 inch
width (or greater) brush point (synthetic or natural bristle) (See Fig.
14) or vacuum cleaner with brush attachment.
Step 7 —
Gently stroke the ionization pins on the top plane of
each bar with enough brush depth to hit front and back tips of the
points in the ionization array. Use a gentle back and forth brushing
motion to clean any small accumulations from the tips of the
points. If desired, use vacuum cleaner with brush attachment to
gently vacuum the frame and components of enhancement module.
Step 8 —
Reinstall the Safety Screen.
Step 9 —
Slide in enhancement module.
Step 10 —
Reconnect the power cord and flow sensor cable.
Step 11 —
Replace the Perfect Air Air Purifier Door
Step 12 —
Turn the Perfect Air Air Purifier switch to the on
position.
Step 13 —
Turn heating and cooling system power on .
30°
POINTS ARE SHARP! BE VERY CAREFUL DURING CLEANING.
Tip of point with residue
Tip of point after cleaning
A06671
Fig. 14 -- Removal of Deposits from Ionization Pins