2

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury.
Ozone in concentrations above 0.05 PPM may be hazardous

to health.
Des concentrations d’ozone superieures a 0.05 PPM peuvent

etre nocives pour la sante.

CAUTION

!

APPLICATION CONSIDERATIONS

The Perfect Air Air Purifier is designed for use in the return air
duct of a forced air heating, cooling, and ventilation system.

Models

GAPABXBB1620,

GAPABXBB2020

and

GAPABXBB2420 are specifically designed for use in systems with
a fan coil.

Air Conditioning

The Perfect Air Air Purifier should be installed in a system so that

all the return air is circulated through the air purifier. It should be

located upstream of the fan coil This will help keep the fan coil
clean and prevent condensation from forming within the Perfect

Air Air Purifier.

Humidifiers

An evaporative humidifier can be mounted upstream of the Perfect
Air Air Purifier. It is best to install atomizing humidifiers

downstream of the air purifier because hard water salt deposits and

water droplets may damage the air purifier. If an atomizing
humidifier must be mounted upstream of the Perfect Air Air

Purifier, it should be mounted as far upstream as possible (at least 6
ft. recommended), and a standard disposable furnace filter should

be mounted between the humidifier and the air purifier to trap hard

water salt deposits and water droplets.

Transitions

If the return air duct or fan coil openings do not fit the Perfect Air

Air Purifier cabinet openings, gradual transitions are recommended
to reduce air turbulence and maximize efficiency. No more than 20

degrees (about 4 in. per running ft.) of expansion should be used

on each side of the transition fitting.

Turning Vanes

If the Perfect Air Air Purifier is installed adjacent to a 90 degree
duct elbow, turning vanes should be added inside duct to improve

air distribution across the face of the air purifier.

Electrical Power / Air Flow Sensor

The Perfect Air Air Purifier should only be powered when airflow

is present. This model is designed for use with a fan coil and is
equipped with an air flow sensor which provides power only when

the fan coil blower is operating (See Fig. 2). Perfect Air Air

Purifier models GAPABXBB1620, GAPABXBB2020, and
GAPABXBB2420 are designed to be powered from a 208/230

VAC power source.

A06387

Fig. 2 -- Air Flow Sensor

Door (x1)

Cabinet (x1)

Enhancement Module (x1)

Safety Screen (x1)

Installation Manual

Return Duct Adapters:
Long (x2) / Short (x2)

Air Flow Sensor (x1)

Air Purification Cartridge (x1)

(x1)

(x2)

(x3)

(x1)

(x2)

Installation Components

(in bag attached to power cord)

(x2)

A07112

Fig. 3 -- Perfect Air Air Purifier Components

GAP

A

B

Summary of Contents for GAPAB

Page 1: ...La Perfect Air Air Purifier certification CSA vise uniquement les risques de choc electrique et A06367 Fig 1 GAPAB Unit SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or ...

Page 2: ...t recommended and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets Transitions If the return air duct or fan coil openings do not fit the Perfect Air Air Purifier cabinet openings gradual transitions are recommended to reduce air turbulence and maximize efficiency No more than 20 degrees about 4 i...

Page 3: ...stem b Remove the existing fan coil filter and discard Excessive sys tem static pressure may result if the Perfect Air Air Purifier is used with other filtration devices c Remove the air purifier cartridge and enhancement module from the Perfect Air Air Purifier cabinet d Position the cabinet between the fan coil and return air duct see Fig 4 and 5 A transition duct may be required NOTE The fan co...

Page 4: ...e power has been removed from the heating and cooling system b Turn the Perfect Air Air Purifier power switch off c Connect the power cord and the flow sensor cord to the power supply connector and the flow sensor connector see Fig 7 and Fig 8 A06414 Fig 7 Flow Sensor Cable Installed A06413 Fig 8 Power Cord Installed NOTE The power cord can be routed through the opposite side of the cabinet Zip ti...

Page 5: ...ranty CAUTION AIR FLOW SENSOR CABLE OR AIR FLOW SENSOR BYPASS PLUG MUST BE CONNECTED TO THE POWER SUPPLY IN ORDER TO ACTIVATE THE AIR PURIFIER NOTICE A06670 Fig 9 Airflow Sensor Bypass Plug Installed TO FAN COIL FIELD POWER CONNECTION FUSED POWER CONNECTOR LEADS FROM INSTALLATION COMPONENTS IN BAG ATTACHED TO POWER CORD AIR PURIFIER POWER CORD TO FAN COIL FIELD POWER CONNECTION TO L2 FIELD POWER S...

Page 6: ...s obtained when the furnace blower is set for continuous operation on the thermo stat or Perfect Air Control MAINTENANCE The Perfect Air Air Purifier is designed to require minimal maintenance Maintenance is limited to the replacement of the air purification cartridge and inspection brush cleaning of the ionization array Frequency of air purifier cartridge replacement and cleaning of the ionizatio...

Page 7: ...ch bar with enough brush depth to hit front and back tips of the points in the ionization array Use a gentle back and forth brushing motion to clean any small accumulations from the tips of the points If desired use vacuum cleaner with brush attachment to gently vacuum the frame and components of enhancement module Step 8 Reinstall the Safety Screen Step 9 Slide in enhancement module Step 10 Recon...

Page 8: ...Step 3 Confirm that the fan coil blower is operating Step 4 Confirm that 208 230 VAC power is provided Attach power supply connector to the air purifier when the fan coil blower is operating NOTE Even though power is supplied to the Perfect Air Air Purifier it will not turn on unless the airflow sensor senses airflow or the airflow sensor s bypass plug is inserted Step 5 Confirm that the airflow s...

Page 9: ...imum Airflow CFM 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCCCAR1620 GAPCCCAR2020 GAPCCCAR2420 Initial Pressure Drop in w c at maximum airflow 22 25 22 DIMENSIONS GAPABXBB1620 GAPABXBB2020 GAPABXBB2420 A 18 1 2 22 25 1 2 B 15 1 8 18 5 8 22 1 8 C 13 1 8 13 1 8 13 1 8 D 17 5 8 21 1 8 24 5 8 E 19 3 4 19 3 4 19 3 4 F 22 1 4 22 ...

Page 10: ...10 GAPAB ...

Page 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Page 12: ...TIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defecti...

Reviews: