16
CONDENSER ONLY RATINGS*
SST
° F (° C)
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
55 (12.78)
65 (18.33)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
115 (46.11)
125 (51.67)
186BNA018****A
30
(---1.11)
TCG
14.00
13.50
13.00
12.40
11.80
11.00
10.20
9.30
SDT
65.20
74.80
84.40
94.00
103.60
113.10
122.60
132.00
KW
0.66
0.78
0.91
1.04
1.20
1.37
1.58
1.83
35
(1.67)
TCG
15.60
15.00
14.50
13.80
13.10
12.30
11.40
10.40
SDT
66.30
75.90
85.40
94.90
104.40
113.80
123.20
132.70
KW
0.65
0.77
0.90
1.04
1.20
1.38
1.58
1.83
40
(4.44)
TCG
17.30
16.70
16.10
15.30
14.60
13.70
12.70
11.70
SDT
67.50
76.90
86.40
95.80
105.20
114.60
124.00
133.30
KW
0.64
0.77
0.90
1.05
1.20
1.38
1.59
1.83
45
(7.22)
TCG
19.10
18.50
17.70
17.00
16.10
15.20
14.20
13.00
SDT
68.70
78.00
87.40
96.70
106.10
115.40
124.80
134.10
KW
0.63
0.77
0.90
1.05
1.21
1.39
1.59
1.83
50
(10.0)
TCG
21.10
20.30
19.50
18.70
17.80
16.70
15.70
14.50
SDT
69.90
79.20
88.40
97.70
107.00
116.30
125.60
134.80
KW
0.63
0.76
0.90
1.05
1.21
1.39
1.60
1.84
55
(12.78)
TCG
23.10
22.30
21.50
20.50
19.50
18.40
17.20
15.90
SDT
71.20
80.40
89.60
98.80
108.00
117.20
126.50
135.60
KW
0.62
0.76
0.91
1.06
1.22
1.40
1.61
1.85
186BNA024*A
30
(---1.11)
TCG
20.10
19.40
18.50
17.60
16.70
15.60
14.40
13.10
SDT
66.10
75.80
85.30
94.90
104.40
114.00
123.40
132.80
KW
0.97
1.13
1.29
1.46
1.65
1.87
2.13
2.42
35
(1.67)
TCG
22.30
21.40
20.50
19.50
18.50
17.30
16.00
14.70
SDT
67.20
76.80
86.30
95.80
105.30
114.70
124.10
133.50
KW
0.96
1.12
1.29
1.46
1.66
1.87
2.13
2.42
40
(4.44)
TCG
24.60
23.70
22.70
21.60
20.40
19.10
17.80
16.30
SDT
68.40
77.90
87.30
96.70
106.10
115.50
124.80
134.10
KW
0.95
1.12
1.29
1.46
1.66
1.88
2.13
2.42
45
(7.22)
TCG
27.10
26.00
24.90
23.70
22.40
21.10
19.60
18.00
SDT
69.60
79.00
88.30
97.60
107.00
116.30
125.60
134.90
KW
0.94
1.11
1.29
1.47
1.67
1.89
2.14
2.43
50
(10.0)
TCG
29.70
28.60
27.30
26.00
24.60
23.10
21.50
19.80
SDT
70.80
80.10
89.40
98.70
107.90
117.20
126.40
135.60
KW
0.93
1.11
1.29
1.47
1.67
1.90
2.15
2.43
55
(12.78)
TCG
32.50
31.20
29.90
28.40
26.90
25.30
23.50
21.70
SDT
72.10
81.30
90.50
99.70
108.90
118.10
127.30
136.40
KW
0.93
1.11
1.29
1.48
1.69
1.91
2.16
2.45
186BNA030000BAAA
30
(---1.11)
TCG
23.80
22.90
21.90
20.90
19.80
18.50
17.00
15.30
SDT
68.10
77.50
87.00
96.40
105.80
115.10
124.40
133.60
KW
1.14
1.32
1.52
1.74
1.99
2.29
2.63
3.02
35
(1.67)
TCG
26.30
25.30
24.30
23.10
21.90
20.50
19.00
17.20
SDT
69.40
78.70
88.10
97.40
106.70
116.00
125.30
134.40
KW
1.15
1.33
1.52
1.75
2.00
2.30
2.64
3.03
40
(4.44)
TCG
29.00
27.90
26.80
25.50
24.20
22.80
21.10
19.20
SDT
70.70
79.90
89.20
98.50
107.70
117.00
126.20
135.30
KW
1.16
1.33
1.53
1.75
2.01
2.31
2.65
3.05
45
(7.22)
TCG
31.90
30.70
29.40
28.10
26.70
25.10
23.40
21.40
SDT
72.00
81.20
90.40
99.60
108.80
118.00
127.20
136.30
KW
1.16
1.33
1.53
1.76
2.01
2.31
2.66
3.06
50
(10.0)
TCG
35.00
33.60
32.30
30.80
29.30
27.60
25.70
23.60
SDT
73.50
82.50
91.60
100.80
110.00
119.20
128.20
137.20
KW
1.16
1.33
1.53
1.76
2.02
2.32
2.67
3.07
55
(12.78)
TCG
38.30
36.80
35.30
33.70
32.00
30.20
28.20
26.00
SDT
75.00
84.00
93.00
102.10
111.20
120.30
129.30
138.20
KW
1.15
1.33
1.53
1.76
2.02
2.32
2.67
3.08
See notes on page 18
186B