![Bryant DuraPac 580F Series Installation, Start-Up And Service Instructions Manual Download Page 30](http://html.mh-extra.com/html/bryant/durapac-580f-series/durapac-580f-series_installation-start-up-and-service-instructions-manual_2822197030.webp)
—
30
—
Table 17 — Fan Performance — 580F240275 (Low Heat Units)*
LEGEND
*Standard low-medium static drive range is 1002 to 1151 rpm. Alternate
high-static drive range is 1193 to 1369. Other rpms require a field-
supplied drive.
Refer to page 32 for general Fan Performance Data notes.
NOTE:
Maximum continuous bhp for the standard motor is 8.7 (for 208/
230-v units) and 9.5 (for 460-v units). The maximum continuous watts is
7915 (for 208/230-v units) and 8640 (for 460-v units). Do not adjust
motor rpm such that motor maximum bhp and/or watts is exceeded at
the maximum operating cfm. See Table 24 for additional information.
AIRFLOW
(Cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.2
0.4
0.6
0.8
1.0
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
6,000
824
2607
3.09
894
2844
3.37
961
3085
3.66
1023
3330
3.95
1083
3578
4.24
6,500
881
3030
3.59
947
3266
3.88
1009
3507
4.16
1069
3751
4.45
1126
3998
4.74
7,000
939
3488
4.14
1001
3725
4.42
1060
3965
4.70
1116
4208
4.99
1170
4454
5.28
7,500
998
3982
4.72
1055
4218
5.00
1111
4458
5.29
1165
4701
5.58
1217
4946
5.87
8,000
1056
4512
5.35
1111
4748
5.63
1164
4988
5.92
1215
5230
6.20
1264
5474
6.49
8,500
1116
5077
6.02
1167
5314
6.30
1218
5553
6.59
1266
5795
6.87
1314
6039
7.16
9,000
1175
5678
6.74
1224
5915
7.02
1272
6154
7.30
1319
6395
7.59
1364
6639
7.88
9,500
1235
6315
7.49
1282
6552
7.77
1327
6791
8.06
1372
7033
8.34
1415
7276
8.63
10,000
1295
6988
8.29
1340
7225
8.57
1383
7465
8.86
1426
7706
9.14
1468
7949
9.43
AIRFLOW
(Cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.2
1.4
1.6
1.8
2.0
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
6,000
1141
3829
4.54
1196
4082
4.84
1249
4337
5.15
1301
4596
5.45
1351
4856
5.76
6,500
1181
4247
5.04
1234
4499
5.34
1285
4753
5.64
1334
5009
5.94
1383
5267
6.25
7,000
1223
4702
5.58
1274
4953
5.88
1323
5205
6.18
1371
5460
6.48
1417
5716
6.78
7,500
1267
5194
6.16
1316
5443
6.46
1363
5694
6.76
1409
5947
7.06
1454
6202
7.36
8,000
1313
5721
6.79
1359
5970
7.08
1405
6220
7.38
1449
6472
7.68
1493
6726
7.98
8,500
1360
6285
7.46
1405
6533
7.75
1449
6783
8.05
1491
7034
8.34
1533
7286
8.64
9,000
1408
6885
8.17
1451
7132
8.46
1494
7381
8.76
1535
7631
9.05
—
—
—
9,500
1458
7521
8.92
1499
7768
9.22
1540
8016
9.51
—
—
—
—
—
—
10,000
1508
8193
9.72
1549
8440
10.01
—
—
—
—
—
—
—
—
—
AIRFLOW
(Cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.2
2.4
2.6
2.8
3.0
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
Rpm
Watts
Bhp
6,000
1399
5118
6.07
1446
5381
6.38
1492
5647
6.70
1537
5914
7.02
—
—
—
6,500
1429
5527
6.56
1475
5789
6.87
1520
6052
7.18
—
—
—
—
—
—
7,000
1462
5974
7.09
1507
6234
7.40
1550
6495
7.71
—
—
—
—
—
—
7,500
1498
6459
7.66
1540
6717
7.97
—
—
—
—
—
—
—
—
—
8,000
1535
6981
8.28
—
—
—
—
—
—
—
—
—
—
—
—
8,500
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
9,000
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
9,500
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
10,000
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bhp
—
Brake Horsepower
Watts —
Input Watts to Motor
Summary of Contents for DuraPac 580F Series
Page 3: ... 3 Fig 1B Roof Curb Details 580F300 A A ...
Page 25: ... 25 Fig 36 Perfect Humidity Dehumidification Package Operation Diagram Single Circuit Shown ...
Page 40: ... 40 Fig 45 Typical Wiring Schematic 580F240 208 230 V Shown ...
Page 41: ... 41 Fig 46 Typical Component Arrangement 580F240 Shown ...
Page 50: ...Copyright 2006 Bryant Heating Cooling Systems Printed in U S A CATALOG NO 04 53580003 01 ...