background image

 

Form No. PDS CC5A.18.6

 

HEATING/COOLING
COIL

 

CC5A, CD5A

 

Sizes 018 thru 060

 

CD5A

CC5A

 

The CC5A and CD5A evaporator coils incorporate proven stan-
dards for reliable system operation and performance throughout
the life of a quality Bryant Air Conditioner or Heat Pump system.
Evaporator coils manufactured by Bryant and installed as part of
a total comfort system provide ARI rated performance ratings
and are additionally listed with UL, c-UL, and RADCO.

The CC5A is an uncased A-coil that provides flexibility for a wide
variety of field applications installed in either a factory manufac-
tured accessory casing, or a field supplied plenum enclosure.

The CD5A is a cased A-coil that is housed in a durable, pre-
painted cabinet. The fully insulated cabinet provides for quiet,
efficient operation of the evaporator coil. 

The coils are available in sizes 018 through 060 (1-1/2–5 tons).

 

COMMON FEATURES

 

Durable Condensate Pan

 

—Each coil is equipped with a corro-

sion resistant condensate drain pan. The condensate drain pan
is designed with a slope to help ensure proper drainage,
improved moisture removal, and home comfort.

 

Brass Inserts

 

—Every condensate pan features two 3/4 in.

female threaded brass insert connections. The Bryant unique
brass inserts provide for a leak-free condensate line connection
to prevent water damage.

 

Refrigerant Connections

 

—The coils are provided with proven

sweat-connections for leak-free operation maintaining system
reliability.

 

Burst Pressures

 

—These coils meet or exceed burst pressure

of 2100 psi which is at least three to five times the pressure they
will see in actual application.

 

External Piston Location

 

—Provides easy access to the piston

metering device, for quick installations and standard service
procedures.

 

Liquid Line Bracket

 

—Holds the piston body in place for quick,

safe piston access without needing a back-up wrench.

 

Neoprene Ring

 

—The ring, installed inside the liquid line con-

nection, is the best option for preventing refrigerant leaks and
future service calls. Neoprene works with both Puron® and R-22
Refrigerant.

 

Protective Tube Sheets

 

—Protect the durable copper tubing

from being damaged during the manufacturing and installation
process.

 

Warranty

 

—All Bryant coils feature a 1-year limited warranty

on parts, with additional extended warranties available for the
system.

 

CC5A FEATURES

 

Coil Support

 

—Bryant provides a standard factory support for

the uncased coil. This provides precise, durable support in the
plenum for easier installations.

 

Face Plate

 

—A unique Bryant feature that provides for a more

professional installation and prevents air leaks at the refrigerant
line connections.

 

CD5A FEATURES

 

Easy Serviceability

 

—Every coil is designed to slide out of the

casing easily, for quick installations and service.

Summary of Contents for CC5A

Page 1: ...ine connection to prevent water damage Refrigerant Connections The coils are provided with proven sweat connections for leak free operation maintaining system reliability Burst Pressures These coils m...

Page 2: ...A Coil D Piston Cased A Coil E Piston Cased Slab F Manufactured Home Uncased A Coil w Piston G Manufactured Home Uncased A Coil w TXV K Piston Cased N Coil A98057 CERTIFICATION APPLIES ONLY WHEN THE C...

Page 3: ...2 1 7 8 22 23 48 21 8 CD5AXW042024 A 24 1 2 622 3 20 1 2 520 7 22 7 8 581 0 7 8 22 23 49 22 2 CD5AXW048024 A 24 1 2 622 3 22 558 8 22 7 8 581 0 7 8 22 23 53 24 0 CD5AXA060024 A 24 1 2 622 3 22 558 8 2...

Page 4: ...8024 A 22 15 16 582 6 20 1 16 509 6 7 8 22 23 31 14 0 CC5AXC048021 A 19 3 8 492 1 20 1 16 509 6 7 8 22 23 27 12 2 CC5AXA060024 A 22 15 16 582 6 20 1 16 509 6 7 8 22 23 31 14 0 CC5AXW060031 A 29 15 16...

Page 5: ...1050 45 56 68 38 49 61 31 41 54 25 33 45 20 23 36 0 14 37 54 32 33 31 29 29 28 26 25 24 23 20 21 19 1400 53 66 79 45 58 72 36 49 63 31 39 53 25 26 42 0 17 45 41 37 41 38 34 36 34 31 31 30 27 25 28 23...

Page 6: ...ressure needed for coil and duct systems Interpolation is permissible Correction Factor 1 09 x 1 BF x db 80 BYPASS FACTOR ENTERING AIR DRY BULB TEMPERATURE F 79 78 77 76 75 Under 75 81 82 83 84 84 Abo...

Page 7: ...4 0 17 0 21 0 24 0 28 W036 WET DRY 900 1000 1100 1200 1300 0 13 0 16 0 19 0 23 0 27 0 11 0 13 0 16 0 18 0 21 A042 WET DRY 1100 1200 1300 1400 0 19 0 22 0 26 0 30 0 16 0 18 0 21 0 25 W042 WET DRY 1100...

Page 8: ...this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats...

Reviews: