5
TO OUTSIDE
OIL
FILTER
SHUTOFF
VALVE
OIL
TANK
VENT PIPE
OIL BURNER
OIL LINES
VENT PIPE
MINIMUM 2 IN. ID
2 IN. FILL PIPE
AUTOMATIC
FILL VALVE
AND SHUTOFF
DIAPHRAGM
EXPANSION TANK
DRAFT
REGULATOR
FOUNDATIONS
ELECTRIC LINE
SERVICE LINE
ENTRANCE
SWITCH
OVERCURRENT
PROTECTED
SAFETY SWITCH
LINES TO OTHER
APPLIANCES
C
H
I
M
N
E
Y
FROM RADIATION
RELIEF VALVE
TO RADIATION
CIRCULATING PUMP
IN SUPPLY LINES
A02230
Fig. 4 -- General Principal Requirements for a Typical Installation
Table 1 – Boiler Ratings and Capacities
WITHOUT
TANKLESS
COIL
NO.
SEC
INPUT
*MBH
**HEATING
CAPACITY
*MBH
NET
I=B=R
RATING
*MBH
FIRING
RATE
GPH
A.F.U.E.
MIN.
CHIMNEY
SIZE/HEIGHT
DIMENSIONS---IN
SHIPPING
WEIGHT
TANKLESS
HEATER
G.P.M.
A
B
C
BW4BAH140
BW4RAH140
3
91
80
70
0.65
#86.3
8” X8” X15’
14 1/2
6
8
460
N/A
3
105
92
80
0.75
#85.2
8” X8” X15’
14 1/2
6
8
460
N/A
3
140
119
103
1.00
83.4
8” X8” X15’
14 1/2
6
8
460
N/A
BW4BAH210
BW4RAH210
4
126
111
97
0.90
#86.0
8” X8” X15’
17 3/4
6
9 5/8
533
N/A
4
175
150
130
1.25
83.9
8” X8” X15’
17 3/4
6
9 5/8
533
N/A
4
210
178
155
1.50
82.4
8” X8” X15’
17 3/4
6
9 5/8
533
N/A
BW4BAH280
BW4RAH280
5
}
168
147
128
1.20
#86.5
8” X8” X15’
21
6
11 1/2
620
N/A
5
245
209
182
1.75
83.6
8” X8” X15’
21
6
11 1/2
620
N/A
5
280
236
205
2.00
82.0
8” X8” X20’
21
6
11 1/2
620
N/A
Shaded areas are as shipped. Alternate inputs require a field---installed alternate oil nozzle supplied with base model.
* MBH = 1,000 BTU per hour/BTU=British Thermal Unit
** Heating Capacity is based on a 13 percent CO2 with a ---0.02 in. wc draft over fire and a #1 smoke or less. Testing was done in accordance with the D.O.E.
(Department
of Energy) test procedure.
+ GPH = Gallons per hour of oil at 140,000 BTU per gallon
++ A.F.U.E. = Annual Fuel Utilization Efficiency based upon D.O.E. test procedure
# As an Energy Star Partner, the manufacturer has determined that this product meets Energy Star guidelines for Energy Efficiency
}
The 168,000 Btuh input is only available with a Beckett burner.
BW
4
/BW
5