background image

4

ACCESSORIES

DESCRIPTION

PART NUMBER

030040 042060 048080 048100 066120

Venting, Drainage and Installation

Vent Kit - Through the Cabinet

KGADC0101BVC

X

X

X

X

X

Vent Terminal - Concentric - 2” (51 mm)

KGAVT0701CVT

X

X

X

X

N/A

Vent Terminal - Concentric - 3” (76 mm)

KGAVT0801CVT

N/A

X

X

X

X

Vent Terminal Bracket - 2” (51 mm)

KGAVT0101BRA

X

X

X

X

N/A

Vent Terminal Bracket - 3” (76 mm)

KGAVT0201BRA

N/A

X

X

X

X

CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVC

KGAAD0110PVC

X

X

X

X

X

Horizontal Trap Grommet - Direct Vent

KGACK0101HCK

X

X

X

X

X

Freeze Protect Kit - Heat Patch for Drain Trap

KGAHT0201CFP

X

X

X

X

X

Freeze Protect Kit - Heat Tape

KGAHT0101CFP

X

X

X

X

X

Furnace Base Kit for Combustible Floors

KGASB0201ALL

X

X

X

X

X

Gas Conversion

Gas Cnv Kit - Nat to LP; Two-stage

KGANP51012SP

X

X

X

X

X

Gas Cnv Kit - LP to Nat; Two-stage

KGAPN43012SP

X

X

X

X

X

Gas Orifice Kit - #42 (Nat Gas)

KGAHA0150N42

X

X

X

X

X

Gas Orifice Kit - #43 (Nat Gas)

KGAHA0250N43

X

X

X

X

X

Gas Orifice Kit - #44 (Nat Gas)

KGAHA0350N44

X

X

X

X

X

Gas Orifice Kit - #45 (Nat Gas)

KGAHA0450N45

X

X

X

X

X

Gas Orifice Kit - #46 (Nat Gas)

KGAHA0550N46

X

X

X

X

X

Gas Orifice Kit - #47 (Nat Gas)

KGAHA1550N47

X

X

X

X

X

Gas Orifice Kit - #48 (Nat Gas)

KGAHA1650N48

X

X

X

X

X

Gas Orifice Kit - #54 (LP)

KGAHA0650P54

X

X

X

X

X

Gas Orifice Kit - #55 (LP)

KGAHA0750P55

X

X

X

X

X

Gas Orifice Kit - #56 (LP)

KGAHA0850P56

X

X

X

X

X

Gas Orifice Kit - 1.25mm (LP)

KGAHA5750125

X

X

X

X

X

Gas Orifice Kit - 1.30mm (LP)

KGAHA5750130

X

X

X

X

X

Indoor Air Quality

Bryant Perfect Air Purifier - 16x25 (406x635 mm)

GAPAAXBB1625-A08

X

X

X

X

X

Bryant Perfect Air Purifier - 20x25 (508x635 mm)

GAPAAXBB2025-A08

X

X

X

X

X

Bryant Perfect Air Purifier Repl. Filter- 16x25 (406x635 mm)

GAPABBCAR1625-A05

X

X

X

X

X

Bryant Perfect Air Purifier Repl. Filter- 20x25 (508x635 mm)

GAPABBCAR1625-A05

X

X

X

X

X

EZ Flex Cabinet 16” (406 mm)

EZXCABBB1016-A20

X

X

X

X

X

EZ Flex Cabinet 20” (508 mm)

EZXCABBB1020-A20

X

X

X

X

X

Cartridge Media Filter - 16” (406 mm)

FILXXCAR0016

X

X

X

X

X

Cartridge Media Filter - 20” (508 mm)

FILXXCAR0020

X

X

X

X

X

Cartridge Media Filter - 24” (610 mm)

FILXXCAR0024

N/A

X

X

X

X

EZ-Flex Filter - 16” (406 mm)

EXPXXFIL0016

X

X

X

X

X

EZ-Flex Filter - 20” (508 mm)

EXPXXFIL0020

X

X

X

X

X

EZ-Flex Filter - 24” (610 mm)

EXPXXFIL0024

N/A

X

X

X

X

EZ-Flex Filter with End Caps - 16” (406 mm)

EXPXXUNV0016

X

X

X

X

X

EZ-Flex Filter with End Caps - 20” (508 mm)

EXPXXUNV0020

X

X

X

X

X

EZ-Flex Filter with End Caps - 24” (610 mm)

EXPXXUNV0024

N/A

X

X

X

X

Filter Pack (6 pack) - Washable - 16x25x1 (406x635x25 mm)

KGAWF1306UFR

X

X

X

X

X

Filter Pack (6 pack) - Washable - 24x25x1 (610x635x25 mm)

KGAWF1506UFR

N/A

X

X

X

X

Controls

Programmable Relative Humidity Thermostat

T6-PRH01-A

X

X

X

X

X

Programmable Thermostat (HP or AC)

T6-PHP01

X

X

X

X

X

Programmable Thermostat (AC only)

T6-PAC01

X

X

X

X

X

Non-Programmable Relative Humidity Thermostat

T6-NRH01

X

X

X

X

X

Non-Programmable Thermostat (HP or AC)

T6-NHP01

X

X

X

X

X

Non-Programmable Thermostat (AC only)

T6-NAC01

X

X

X

X

X

X = Used with this model furnace
N/A = Not used with this model furnace

Summary of Contents for 925TA

Page 1: ...em S Fan On Plus technology allows control of continuous fan speed from a compatible thermostat S External Media Filter Cabinet included S 4 way multipoise design for upflow downflow or horizontal ins...

Page 2: ...ry Supplied Media Cabinet Field Supplied Filter Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR KGAWF1506UFR Electrical Data 030040 042060 048080 048100 066120...

Page 3: ...66 2200 CFM 0 5 ESP 040 40 000 BTU 060 60 000 BTU 080 80 000 BTU 100 100 000 BTU 120 120 000 BTU Not all familes have these models A11164 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DO...

Page 4: ...as Orifice Kit 1 30mm LP KGAHA5750130 X X X X X Indoor Air Quality Bryant Perfect Air Purifier 16x25 406x635 mm GAPAAXBB1625 A08 X X X X X Bryant Perfect Air Purifier 20x25 508x635 mm GAPAAXBB2025 A08...

Page 5: ...0 1050 2 Org 1180 1130 1095 1060 1015 975 935 895 850 800 1 Red 1100 1045 1010 970 920 885 845 790 745 690 100000 SIDE BOTTOM 5 Gry 2040 1970 1885 1795 1720 1635 1540 1450 1360 1230 4 Yel 1550 1505 14...

Page 6: ...202 61 6 224 68 3 100 000 NA 17 5 2 94 28 7 205 62 5 229 69 8 120 000 NA NA NA 83 25 3 217 66 1 Not all families have these models NOTE See notes at end of venting tables NOTE See Table 3 for altitude...

Page 7: ...0 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 9001 to 10 000 2743 to 304...

Page 8: ...0 125 0 20 0 70 0 175 0 177 0 147 0 M 6 1 19 5 19 5 17 1 14 3 6 1 21 3 52 7 45 7 38 1 6 1 21 3 53 3 53 9 44 8 0 20 Ft 20 0 32 0 30 0 22 0 11 0 20 0 70 0 104 0 87 0 67 0 20 0 70 0 124 0 104 0 82 0 M 6...

Page 9: ...heat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in struct...

Page 10: ...ed Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric...

Page 11: ...ELD SUPPLIED FUSED DISCONNECT JUNCTION BOX 24 VOLT TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 2 NOTE 1 1 STAGE THERMOSTAT TERMINALS FIELD SUPPLIED FUSED DISCONNECT CONDENSING UNIT FURNACE C...

Page 12: ...B OUTLET WIDTH A 22 558 3 14 13 16 376 3 35 889 0 5 8 15 8 1 5 16 33 3 29 1 2 749 3 19 1 8 485 8 VENT AIR INTAKE AIR FLOW AIR FLOW SIDE INLET SIDE INLET CONDENSATE DRAIN TRAP LOCATION THERMOSTAT ENTRY...

Page 13: ...___ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted galvanized steel Draft Inducer Motor Draft inducer motor shall be two speed design Primary Heat Exchangers Primary heat...

Page 14: ...change at any time specifications or designs without notice and without incurring obligations E2011 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition D...

Reviews: