background image

5

ACCESSORIES

DESCRIPTION

PART NUMBER

30040

36060

36040

48060

48080

60080

48100

60100

60120

Venting Accessories

Vent Kit - Through the Cabinet

KGADC0101BVC

D

D

D

D

D

D

D

D

D

Vent Terminal - Concentric - 2” (51 mm)

KGAVT0701CVT

See Venting Tables

Vent Terminal - Concentric - 3” (76 mm)

KGAVT0801CVT

Vent Terminal Bracket - 2” (51 mm)

KGAVT0101BRA

Vent Terminal Bracket - 3” (76 mm)

KGAVT0201BRA

Vent Kit --- Rubber Coupling

KGAAC0101RVC

See Venting Tables

Condensate Drainage Accessories

Freeze Protect Kit - Trap Heater

KGAHT0201CFP

D

D

D

D

D

D

D

D

D

CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVC

KGAAD0110PVC

D

D

D

D

D

D

D

D

D

Horizontal Trap Grommet - Direct Vent

KGACK0101HCK

All DV Horizontal

Condensate Neutralizer Kit

P908---0001

D

D

D

D

D

D

D

D

D

External Trap Kit

KGAET0201ETK

D

D

D

D

D

D

D

D

D

Ductwork Adapter Accessories

Furnace Base Kit for Combustible Floors

KGASB0201ALL

D

D

D

D

D

D

D

D

D

Coil Adapter Kits --- No Offset

KGADA0101ALL

D

D

D

D

D

D

D

D

D

Coil Adapter Kits --- Single Offset

KGADA0201ALL

D

D

D

D

D

D

D

D

D

Coil Adapter Kits --- Double Offset

KGADA0301ALL

D

D

D

D

D

D

D

D

D

Return Air Base (Upflow Applications) 14.0---in. wide

KGARP0301B14

D

D

Return Air Base (Upflow Applications) 17.5---in. wide

KGARP0301B17

D

D

D

Return Air Base (Upflow Applications) 21.0---in. wide

KGARP0301B21

D

D

D

Return Air Base (Upflow Applications) 24.5---in. wide

KGARP0301B24

D

IAQ Device Duct Adapters 20.0---in. IAQ to 16 in. Side

Return

KGAAD0101MEC

20”x25” IAQ Devices

IAQ Device Duct Adapters 24.0---in. IAQ to 16 in. Side

Return

KGAAD0201MEC

24”x25” IAQ Devices

Gas Conversion Accessories

Mobile Home Kit

KGBMH0601KIT

D

D

D

D

D

D

D

D

D

Gas Conversion Kit - Nat to LP

KGBNP50011SP

D

D

D

D

D

D

D

D

D

Gas Conversion Kit - LP to Nat

KGBPN42011SP

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #42 (Nat Gas)

LH32DB207

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #43 (Nat Gas)

LH32DB202

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #44 (Nat Gas)

LH32DB200

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #45 (Nat Gas)

LH32DB205

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #46 (Nat Gas)

LH32DB208

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #47 (Nat Gas)

LH32DB078

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #48 (Nat Gas)

LH32DB076

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #54 (LP)

LH32DB203

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #55 (LP)

LH32DB201

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - #56 (LP)

LH32DB206

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - 1.25mm (LP)

LH32DB209

D

D

D

D

D

D

D

D

D

Gas Orifice Kit - 1.30mm (LP)

LH32DB210

D

D

D

D

D

D

D

D

D

Control Accessories

Twinning Kit

KGATW0701HSI

D

D

D

D

D

D

D

IAQ Accessories

Filter Rack --- Side Return for 1” Filters

KGAFR0201ALL

D

D

D

D

D

D

D

D

D

Filter Rack --- Bottom Return for 1” Filters --- 14.2” wide

KGBFR0401B14

D

D

D

Filter Rack --- Bottom Return for 1” Filters --- 17.5” wide

KGBFR0501B17

D

D

Filter Rack --- Bottom Return for 1” Filters --- 21.0” wide

KGBFR0601B21

D

D

D

Filter Rack --- Bottom Return for 1” Filters --- 24.5” wide

KGBFR0701B24

D

Filter Pack (6 pack) --- Washable - 16x25x1

KGAWF1306UFR

D

D

D

D

D

D

D

D

D

Filter Pack (6 pack) --- Washable - 24x25x1

KGAWF1506UFR

D

D

D

D

D

D

D

D

D

EZ-Flex Filter - 16” (406 mm)

EXPXXFIL0016

Use with EZXCAB---1016

EZ-Flex Filter - 20” (508 mm)

EXPXXFIL0020

Use with EZXCAB---1020

EZ-Flex Filter - 24” (610 mm)

EXPXXFIL0024

Use with EZXCAB---1024

EZ-Flex Filter with End Caps - 16” (406 mm)

EXPXXUNV0016

Use with EZXCAB---1016

EZ-Flex Filter with End Caps - 20” (508 mm)

EXPXXUNV0020

Use with EZXCAB---1020

EZ-Flex Filter with End Caps - 24” (610 mm)

EXPXXUNV0024

Use with EZXCAB---1024

Cartridge Media Filter - 16” (406 mm)

FILXXCAR0016

Use with FILCABXL---1016

Cartridge Media Filter - 20” (508 mm)

FILXXCAR0020

Use with FILCABXL---1020

Cartridge Media Filter - 24” (610 mm)

FILXXCAR0024

Use with FILCABXL---1024

EZ Flex Cabinet Side or Bottom Return 4” Filters --- 16”

EZXCABCC0016

D

D

D

D

D

EZ Flex Cabinet Side or Bottom Return 4” Filters --- 20”

EZXCABCC0020

D

D

D

EZ Flex Cabinet Side or Bottom Return 4” Filters --- 24”

FILCABXL0024

D

D

= Used with the model furnace

912SC

Summary of Contents for 912SC

Page 1: ...eight 35 cabinet short enough for taller coils but still allows enough room for service S Silicon Nitride Perfect Lightt Hot Surface Igniter S Aluminized steel primary heat exchanger S Stainless steel...

Page 2: ...product a design with more than ten years of field proven performance and success These innovations paired with the continuation of a crimped no weld seam create an efficient robust design for this e...

Page 3: ...970 2050 Cooling Capacity tons 400 CFM ton 2 5 2 5 2 5 3 5 4 4 5 3 5 5 5 350 CFM ton 2 5 3 3 4 4 5 5 0 4 0 5 5 5 5 Direct Drive Motor Type Permanent Split Capacitor PSC Direct Drive Motor HP 0 3 0 5 0...

Page 4: ...U 120 120 000 BTU 140 140 000 BTU Not all familes have these models 0 90 AFUE 2 92 AFUE 3 93 AFUE 5 95 AFUE 6 96 AFUE 7 97 AFUE Example of a Model Number A12374 FURNACE COMPONENTS RATING PLATE NOT SHO...

Page 5: ...Nat Gas LH32DB202 D D D D D D D D D Gas Orifice Kit 44 Nat Gas LH32DB200 D D D D D D D D D Gas Orifice Kit 45 Nat Gas LH32DB205 D D D D D D D D D Gas Orifice Kit 46 Nat Gas LH32DB208 D D D D D D D D...

Page 6: ...nge 3 5 397 1485 1470 1455 1430 1390 1340 1280 1205 1120 1035 Blue 3 2 5 426 1120 1110 1100 1090 1065 1035 990 935 870 805 Red 3 2 0 433 940 920 910 890 865 830 790 745 690 625 048100 SIDE BOTTOM Blac...

Page 7: ...Temp C Unit Size 40 000 BTUH 60 000 BTUH Uninsulated 3 8 in Insulation 1 2 in Insulation Uninsulated 3 8 in Insulation 1 2 in Insulation Pipe Dia mm 38 51 64 38 51 64 38 51 64 38 51 64 76 38 51 64 76...

Page 8: ...ize 40 000 Outlet choke required under 10 ft TEVL 60 000 80 000 100 000 120 000 140 000 Altitude meters Pipe Dia mm 38 51 64 38 5 64 76 38 51 64 76 102 51 64 76 102 64 76 102 64 76 102 0 610 6 26 57 6...

Page 9: ...eters of PVC ABS pipe VERIFY FROM VENT MANUFACTURER S INSTRUCTIONS Can this application use 60 mm O D polypropylene vent piping If not what size piping can be used Measure the required linear length o...

Page 10: ...PLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sid...

Page 11: ...1 2 YES YES NO YES 60 000 14 3 16 YES YES NO YES 17 1 2 YES NO NO YES 80 000 17 1 2 YES YES NO YES 21 YES YES NO YES 100 000 21 YES YES NO YES 120 000 24 1 2 YES YES NO YES INPUT CASING WIDTH INCHES...

Page 12: ...5 8 600 2 24 1 2 622 Furnace with or without Cased Coil Assembly or Coil Box 22 1 8 562 19 483 23 3 4 603 20 5 8 600 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the...

Page 13: ...SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND...

Page 14: ...S IN INCH MM 22 2 7 8 7 8 22 2 POWER CONN AIR FLOW SEE NOTE 3 NOTES 1 Doors may vary by model 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct manufactur...

Page 15: ...accessory highly efficient Media Filter is available as an option _____________ Media Filter Casing Casing shall be of 030 in thickness minimum pre painted steel Draft Inducer Motor Draft inducer mot...

Page 16: ...e or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 10 14 Re...

Reviews: