OPTIONS AND ACCESSORIES

Factory--installed options
Coil options

include tin--plated* indoor hairpins, copper/copper

and vinyl--coated construction for refrigerant coils. Units are
shipped standard with copper tube/aluminum fin construction.

See model number nomenclature for coil options.
*Tin--plated indoor coils are built with special hairpins that are
designed to resist both general pitting corrosion and excessive

indoor corrosion (Formicary Corrosion).

Field--installed accessories

Manual Air Damper (25% open)
Electric Heaters
Filter Rack
Flat Roof Curbs (8--in. and 14--in.)
Square--to--Round Duct Transition Kit
Evolution

t

User Interface

Crankcase Heater

Low--Ambient Kit (Motormaster II Control)
Lifting Kit
Compressor Hard Start Kit

Manual outside air damper

includes hood and filter rack with

adjustable damper blade for up to 25% outdoor air.

Electric heaters

provide additional heat in the unit when

required. Each package has a heater module that slides into the

controls compartment. Heater sizes range from 5.0 to 20.0 kW.

The electric heater design allows the use of a single--point power
supply for the entire unit, resulting in lower installed costs.

Flat roof curbs

in both 8 in. and 14 in. sizes are available for

roof mounted applications.

Square--to--round duct transition kit

enables 024--048 size

units to be fitted to 14 in. round ductwork.

Evolution User Interface

coupled with the system’s

variable--speed indoor blower delivers Bryant’s patented
PerfectHumidity technology that allows for even greater humidity

control. Along with more precisely controlling temperature and

humidity, the Evolution User Interface offers full seven--day
programmability allowing you to further customize your comfort

and energy savings.

Lifting kit

includes 4 metal brackets that are available to assist in

lifting this product onto a roof application.

Crankcase heater

provides anti--floodback protection for

low--load cooling applications.

Low--ambient kit (Motormaster

®

II control)

allows the use of

mechanical cooling down to outdoor temperatures as low as 0

°

F.

Filter rack

features easy installation, serviceability, and

high--filtering performance for vertical or horizontal applications.

Compressor hard start kit

assists compressor start--up by

providing additional starting torque on single--phase units and
prolongs compressor motor life.

Electric Heaters

ODS Catalog

Nominal

Capacity

Used With Sizes

Ordering No.

(kW)

Fused

Stages

24

30

36

42

48

60

208/230 —SINGLE PHASE —60 Hz

CPHEATER080A00

3.8 / 5.0

NO

1

X

X

X

X

X

X

CPHEATER082A00

5.4 / 7.2

NO

1

X

X

X

X

X

X

CPHEATER084A00

7.5 / 10.0

NO

1

X

X

X

X

X

X

CPHEATER086A00

11.3 / 15.0

YES

2

X

X

X

X

X

CPHEATER088A00

15.0 / 20.0

YES

2

X

X

X

X

208/230 -- THREE PHASE -- 60 Hz

CPHEATER090A00

3.8 / 5.0

NO

1

X

X

X

X

CPHEATER091A00

7.5 / 10.0

NO

1

X

X

X

X

CPHEATER093A00

11.3 / 15.0

NO

2

X

X

X

X

CPHEATER095A00

15.0 / 20.0

YES

2

X

X

X

NOTE

Electric heaters are rated at 240v. Refer to Multiplication Factors table for other voltages.

LEGEND

ODS—Order Distribution System

704C

Summary of Contents for 704C EVOLUTION

Page 1: ...iency Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation Vibration isolation provides quiet operation Compressors have internal high pres...

Page 2: ...ch keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality Conforms to American Society of Heating Refrigeration and Air Conditioning...

Page 3: ...A SEER Sound Ratings dBA 024 2 800 24 000 11 13 0 72 030 2 1 2 1000 28 800 11 13 0 72 036 3 1200 36 000 11 13 0 74 042 3 1 2 1400 41 000 11 13 0 74 048 4 1600 45 000 11 13 0 78 060 5 1750 57 000 11 1...

Page 4: ...fficiency 700 875 1050 1225 1400 1750 Max 800 1000 1200 1400 1600 2000 Size in 10x10 10x10 11x10 11x10 11x10 11x10 Motor HP RPM 1 2 1 2 3 4 3 4 3 4 1 HIGH PRESSURE SWITCH psig 650 15 420 25 Cutout Res...

Page 5: ...m s variable speed indoor blower delivers Bryant s patented PerfectHumidity technology that allows for even greater humidity control Along with more precisely controlling temperature and humidity the...

Page 6: ...FILTER RACK EVAPORATOR COIL TOP FILTER RACK BEND FLANGE AT 90 SCREW TO DIVIDER WITH 1 IN SCREW BOTTOM FILTER RACK MANUAL OUTSIDE AIR DAMPER DAMPER BLADE MANUAL OUTSIDE AIR HOOD REPLACEMENT PANEL 704C...

Page 7: ...7 A06120 704C024 036 Unit Dimensions 704C...

Page 8: ...8 A06121 704C042 060 Unit Dimensions 704C...

Page 9: ...G E F G D E A05308 UNIT SIZE ODS CATALOG NUMBER A IN MM B IN MM C IN MM D IN MM E IN MM F IN MM G IN MM 704C024 036 CPRFCURB006A00 8 203 11 279 16 1 2 419 28 3 4 730 30 3 8 771 44 5 16 1126 45 15 16 1...

Page 10: ...ased on required cooling capacity Enter Net Cooling Capacities table at condenser entering temperature of 95 F The 036 unit at 1200 cfm and 67 F ewb entering wet bulb will provide a total capacity of...

Page 11: ...21 1 17 8 18 0 19 4 21 4 SHC 17 8 17 0 14 5 11 7 18 5 18 1 15 5 12 3 kW 2 8 2 8 3 0 3 0 2 9 2 9 3 0 3 0 Cooling Extended Performance Table 704C030 Temp F Outdoor Air Entering Condenser Evaporator Air...

Page 12: ...8 5 31 5 28 1 27 2 29 3 32 3 SHC 26 2 20 9 21 9 17 1 27 8 23 5 24 7 18 9 kW 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 4 Cooling Extended Performance Table 704C042 Temp F Outdoor Air Entering Condenser Evaporator...

Page 13: ...5 3 38 8 34 6 33 3 35 9 39 5 SHC 32 4 27 0 28 4 21 9 34 1 28 9 30 6 23 3 kW 5 5 5 4 5 5 5 5 5 5 5 5 5 5 5 5 Cooling Extended Performance Table 704C060 Temp F Outdoor Air Entering Condenser Evaporator...

Page 14: ...ES 1 Ratings are net they account for the effects of the evaporator fan motor power and heat 2 Direct interpolation is permissible Do not extrapolate 3 The following formulas may be used Sensible capa...

Page 15: ...IR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX FIELD SUPPLIED SUPPLY AIR FLEXIBLE DUCT ROOF MOUNTING CURB C00023 USER INTERFACE DISCONNECT PER NEC FROM POWER SOURCE RETURN AIR TOP COVER FROM GAS LIN...

Page 16: ...nflow openings Remove theinsertssimilar toremoving anelectrical knockout Leave onduct covers to seal the horizontal discharge openings in the unit Units installed in horizontal discharge orientation d...

Page 17: ...6 60 6 60 70 11 3 15 0 54 2 62 5 76 2 86 6 80 90 15 0 20 0 72 2 83 3 98 8 112 7 100 125 208 230 3 60 187 253 15 4 88 0 0 8 6 8 26 9 26 9 35 35 3 8 5 0 10 4 12 0 26 9 26 9 30 35 7 5 10 0 20 8 24 1 34...

Page 18: ...a phase imbalance in supply volt age is greater than 2 Use the following formula to determine the percentage of voltage imbalance Voltage imbalance max voltage deviation from average voltage 100 x av...

Page 19: ...19 TYPICAL WIRING SCHEMATIC 230 1 60 7 0 A06126 704C...

Page 20: ...20 TYPICAL WIRING SCHEMATIC 230 3 60 5 0 A06127 704C...

Page 21: ...capacity as defined by unit size Actual airflow request will be adjusted from nominal using indoor and outdoor temperature and indoor humidity data to optimize the system operation for occupant comfo...

Page 22: ...ation capableof beingwiped clean Aluminum foil faced fiberglass insulation shall be used in the entire indoor air cavity seciton 5 Unit shall have a field supplied condensate trap C Fans 1 The indoor...

Page 23: ...tion whichshallallow unitto operatedown to0 F outdoorambi ent temperature in cooling 6 Filter Rack Kit Shall provide filter mounting for downflow and horizontal applications 7 Square To Round Duct Tra...

Page 24: ...e or change at any time specifications or designs without notice and without incurring obligations E2006 Bryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in U S A Edition...

Reviews: