—18—
DETAILED COOLING CAPACITIES
*
Continued
See notes on page 21.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
System
Kw
**
Capacity
MBtuh†
Total
System
Kw
**
Capacity
MBtuh†
Total
System
Kw
**
Capacity
MBtuh†
Total
System
Kw
**
Capacity
MBtuh†
Total
System
Kw
**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
597CN036-F Outdoor Section With CC5A/CD5AA036 Indoor Section Continued
1050
72
39.0
19.3
2.91
37.6
18.7
3.23
35.9
18.1
3.56
34.2
17.5
3.9
32.5
16.9
4.36
67
35.8
24.5
2.89
34.4
23.9
3.21
32.8
23.2
3.53
31.3
22.6
3.9
29.7
22.0
4.32
62
32.7
29.4
2.87
31.4
28.8
3.19
30.0
28.1
3.51
28.6
27.4
3.8
27.1
26.5
4.29
57
31.3
31.3
2.87
30.3
30.3
3.18
29.2
29.2
3.51
28.0
28.0
3.8
26.9
26.9
4.29
1200
72
39.7
20.2
2.97
38.2
19.6
3.29
36.5
19.0
3.62
34.8
18.4
4.0
32.8
17.7
4.40
67
36.4
26.0
2.95
35.0
25.4
3.27
33.4
24.7
3.60
31.8
24.1
3.9
30.2
23.5
4.39
62
33.4
31.4
2.94
32.0
30.7
3.24
30.6
29.9
3.59
29.1
28.9
3.9
27.8
27.8
4.34
57
32.5
32.5
2.93
31.4
31.4
3.25
30.3
30.3
3.58
29.0
29.0
3.9
27.8
27.8
4.35
1350
72
40.3
21.0
3.03
38.5
20.4
3.33
36.9
19.8
3.69
35.1
19.2
4.0
33.2
18.5
4.47
67
36.9
27.4
3.01
35.3
26.7
3.31
33.8
26.2
3.66
32.2
25.5
4.0
30.3
24.8
4.42
62
33.9
33.1
3.00
32.5
32.2
3.29
31.2
31.2
3.64
29.9
29.9
4.0
28.5
28.5
4.40
57
33.5
33.5
2.99
32.4
32.4
3.31
31.2
31.2
3.64
29.9
29.9
4.0
28.5
28.5
4.40
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CK3BA
036
1.00
0.92
CK3BA
036
1.00
0.94
042
1.00
0.92
042
1.00
0.94
CK5A/CK5BA
042
1.00
0.92
CK5A/CK5BA
042
1.00
0.94
CK5A/CK5BW
036
1.00
0.92
CK5A/CK5BW
036
1.00
0.94
COILS + 355MAV060120 VARIABLE SPEED FURNACE
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CK5A/CK5BA
042
1.00
0.92
CC5A/CD5AA
036
1.01
0.92
CK5A/CK5BW
036
1.00
0.92
042
1.01
0.93
—
—
—