background image

3

FACTORY--INSTALLED OPTIONS (FIOPs)

j

Economizer with D

RY

B

ULB

sensing and barometric

relief

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with D

RY

B

ULB

sensing and barometric

relief

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er 2.

j

2--Speed Indoor Fan Motor system utilizes a Variable

Frequency Drive (VFD) to automatically adjust the indoor

fan motor for 2 speed indoor fan motor control. Conforms

to ASHRAE 90.1 2010 Standard – section 6.4.3.10.b.

j

RTU Open multi--protocol controller communicates to

LON, MODBUS, BACNET and Johnson N2 protocols.

j

Through the base connectors electric conduit

j

Two--position motorized outdoor air damper

j

Non--fused disconnect switch (80 A Max)

j

Powered 115--volt convenience outlet

j

Non--powered 115--volt convenience outlet

j

High static indoor fan motor and drive

j

Return Air smoke detector

j

Supply Air smoke detector

j

Pre--coated Al/Cu condenser coil

j

E--coated Al/Cu condenser coil

j

E--coated Al/Cu condenser and evaporator coil

j

Cu/Cu condenser coil

j

Cu/Cu condenser coil and evaporator coil

j

Condenser hail guard — louvered style

j

CO

2

sensor

OPTIONAL WARRANTIES

j

Complete Unit Parts only up to 5 years

j

Complete Unit Parts and Labor up to 5 years
Many other optional warranties are available.

See the

Commercial Start--Up and Optional Extended

Warranty Price

price pages for further information.

548J

***D

Summary of Contents for 548J*08D

Page 1: ...onvertible from vertical to horizontal airflow for slab mounting S Two inch disposable return air filters S Thru the bottom power entry capability S Single point electric connections on field installe...

Page 2: ...Entering Air db _F wb _F Airflow CFM External Static Pressure in wg Curb Weight lb Heating Power Input to Unit kw Integrated Capacity Btuh Indoor Operating Air Temperature _F db Outdoor Air Temperatu...

Page 3: ...j Economizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets California Title 24 section 120 2 Fault Detection and Diagnostic FDD requiremen...

Page 4: ...equirements EconoMi er 2 j Economizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets California Title 24 section 120 2 Fault Detection and...

Page 5: ...5 CERTIFIED DIMENSION 548J 08 09D C12051 548J D...

Page 6: ...6 CERTIFIED DIMENSION 548J 08 09D C12052 548J D...

Page 7: ...7 CERTIFIED DIMENSION 548J 12D C12053 548J D...

Page 8: ...8 CERTIFIED DIMENSION 548J 12D C12054 548J D...

Page 9: ...9 CERTIFIED DIMENSION 548J 14D C14194 548J D...

Page 10: ...10 CERTIFIED DIMENSION 548J 14D C14195 548J D...

Page 11: ...THE WRITTEN AUTHORIZATION OF CARRIER CORPORATION 1 DEC 2 DEC 3 DEC ANG MATERIAL AUTHORIZATION NUMBER TITLE 1029120 CURB ASY ROOF ENGINEERING MANUFACTURING ENGINEERING REQUIREMENTS SIZE DRAWING NUMBER...

Page 12: ...t to discontinue or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Editio...

Reviews: