A00231b

11

NO PREVIOUS F

A

UL

T - F

aults are

er

ased after 72 hrs

. Run system through

a lo

w-heat, high-heat or cooling cycle to

chec

k system.

12

BLO

WER ON AFTER PO

WER

UP (115V OR 24V) - Nor

mal

operation.  Blower will run for 90

sec when furnace power is

interrupted during a call for heat,

R-W closed.

13

LIMIT

, DRAFT SAFEGU

ARD

, FLAME

R

OLLOUT SWITCH OR BLOCKED 

VENT

SWITCH (WHEN USED) LOCK

OUT -

An

y of these s

witches was open longer

than 3 minutes.  

Auto-reset will occur after

3 hrs.  Flame rollout s

witch or b

loc

ked v

ent

switch (when used) requires manual reset.

       See No. 33

14

IGNITION LOCK

OUT - System

failed to ignite gas and prove

flame in 4 attempts. Control will

auto-reset in 3 hrs.

        See No. 34

21

GAS HEA

TING LOCK

OUT -

Turn of

f power and wait 5

minutes to retry

.

Check for:

Unplug igniter harness from control

and inititate another component test

sequence.  Check f

or 1

15v between

pins 1 and 2 on the control.  W

as 1

15v

present f

or the 17-sec period?

Replace control.

Check for continuity in the harness

and igniter

. Replace defective

component.

Reconnect the R thermostat lead

and set thermostat to call for heat.

Connect voltmeter across gas valve

connections.  Does gas valve

receive 24v?

Check connections. If OK, replace

control.

Does gas valve open and allow gas

to flow?

Check that all gas valves are turned

on. Replace valve.

Do main burners ignite?

Do main burners stay on?

Allow blower to come on and repeat

test to check for intermittent

operation.

Repeat call for heat and check flame

sensor current during trial for ignition

period.  Is the DC microamps

below 0.5?

Check connections and retry

. If

current is near typical value and

bu

rners will not stay on, replace

control.

Clean flame sensor with fine steel w

ool and

recheck current.

 Current is nominally 4.0 to

6.0 microamps.

Is current near typical value?

Replace electrode.

Will main burner ignite and stay on?

Replace control.

Fixed.

Stuck closed gas valve relay

on control.

Miswire or short to gas valve

wire.

22

ABNORMAL FLAME PR

O

VING

SIGNAL - Flame w

as sensed

while gas valve was

de-energized. Inducer will run

until fault is cleared.

Check for:

Stuck open gas valve solenoid

or leak.

23

PRESSURE SWITCH DID

NO

T OPEN - Chec

k f

or

:

Disconnected or obstructed

pressure tubing.

Defective pressure switch.

24

SECOND

AR

V

O

LT

A

GE FUSE IS

OPEN - Chec

k f

or

:

Short in low-voltage wiring

including thermostat leads

shorting to ductwork or

furnace cabinet. Disconnect

thermostat leads to isolate

short circuit.

32

LO

W

-HEA

T PRESSURE SWITCH

DID NO

T CLOSE OR REOPENED

- If open longer than 5 minutes,

inducer shuts of

f for 15 minutes

before retry

.

Check for:

Proper vent sizing or pitch or

sag.

Vent restrictions or high winds.

Defective inducer motor

.

Low line voltage (1

15v).

Low inlet gas pressure (if LGPS used).

Defective pressure switch or

connections. If it opens after

trial for ignition period, blower

will come on for 90 sec

recycle delay

.

Inadequate combustion air

.

33

LIMIT

, DRAFT SAFEGU

ARD

, FLAME

R

OLLOUT SWITCH OR BLOCKED 

VENT

SWITCH (WHEN USED) IS OPEN - If an

y

switch is open longer than 3 min

utes

, code

changes to No

. 13.

 Chec

k f

or

:

Blower motor failure.

Motor start capacitor

.

Open flame rollout switch, manual reset.

Dirty filter or restr

icted duct system.

Defective limit switch or connections.

Loose blower wheel.

34

IGNITION PR

O

VING F

AILURE -

If flame is not sensed during the

trial for ignition period, the control

will repeat the ignition sequence

3 more times before going into

lockout, No. 14.

If flame signal is lost after trial for

ignition period, blower will come

on for 90-sec recycle delay

.

Check for the following items first

before proceeding to the next step.

Gas valve turned of

f.

Manual shut-of

f valve.

Green/Y

ello

w wire must be

connected to furnace sheet metal.

To

 determine whether the

problem is in the gas valve,

igniter

, or flame sensor

, the

system can be operated in the

component test mode to check

the igniter

. First, remove the

R thermostat connection from the

control and initiate the

component test sequence.  Does

the igniter glow orange/white hot

by the end of the 15-sec warm-up

period?

Check for:

Inadequate flame carryover or

rough ignition.

Low inlet gas pressure.

NO

YES

YES

YES

YES

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

NO

NO

Inadequate combustion air supply

(flame rollout switch open).

NO

Restr

icted v

ent.

Proper v

ent sizing.

Excessiv

e wind.

45

CONTR

OL CIRCUITR

Y LOCK

OUT

-

A

uto-reset after one hour

. Loc

kout

due to:

•  Flame-sense circuit f

ailure

.

•  Gas v

alv

e rela

y stuc

k open

•  Softw

are chec

k error

Reset po

w

er to clear loc

kout.

Replace control if status code

repeats

.

—11—

Summary of Contents for 312AAV L Series

Page 1: ...nd the signal words DANGER WARNING CAUTION and NOTE These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WA...

Page 2: ...uum cleaners or other cleaning tools 2 Soap powders bleaches waxes or other cleaning compounds plastic or plastic containers gasoline kerosene cigarette lighter fluid dry cleaning fluids or other vola...

Page 3: ...furnace casing and away from blower compartment 8 Remove 2 screws holding blower assembly to blower deck and slide blower assembly out of furnace 9 Clean blower wheel and motor using a vacuum with so...

Page 4: ...y combustion air incorrect size or damaged manifold orifice s improper gas or a restricted heat exchanger Action must be taken to correct the problem If it becomes necessary to clean the heat exchange...

Page 5: ...proper operation 16 Verify blower airflow and speed changes between heating and cooling 17 Check for gas leaks WARNING Never use a match or other open flame to check for gas leaks Use a soap and wate...

Page 6: ...LED status 4 If furnace is operating properly and continuously lit LED indicates proper operation replace outer access door 5 Component Test can also be initiated by performing the following a Remove...

Page 7: ...nds 15 Blower off delay gas heating selections are 90 120 150 180 seconds cooling or heat pump 90 seconds or 5 seconds when DHUM is on LEGEND ACR AIR CONDITIONING RELAY SPST N O ACRDJ AIR CONDITIONING...

Page 8: ...omponent After replacing any component verify correct operation sequence Fig 8 Furnace Control A00380 LHT OFF DLY ON OFF W2 BLW 24 V THERMOSTAT TERMINALS SETUP SWITCHES LOW HEAT ONLY AND BLOWER OFF DE...

Page 9: ...for Short circuit in secondary voltage 24VAC wiring 31 HIGH HEAT PRESSURE SWITCH OR RELAY DID NOT CLOSE OR REOPENED Check for Control relay may be defective Refer to 32 32 LOW HEAT PRESSURE SWITCH DID...

Page 10: ...speed and run for the entire component test then shift to low speed for 10 seconds The HSI blower motor low heat speed blower motor high heat speed and blower motor cool speed will run for 10 15 sec e...

Page 11: ...PEN Check for Disconnected or obstructed pressure tubing Defective pressure switch 24 SECONDARY VOLTAGE FUSE IS OPEN Check for Short in low voltage wiring including thermostat leads shorting to ductwo...