Product Data

MODEL 225A

LEGACY

t

LINE 15 HEAT PUMP

WITH PURON

r

REFRIGERANT

1--1/2 TO 5 NOMINAL TONS (SIZES 018 TO 060)

TM

the environmentally sound refrigerant

Bryant’s heat pumps with Puron

r

refrigerant provide a collection

of features unmatched by any other family of equipment. The

225A has been designed utilizing Bryant’s Puron refrigerant. The

environmentally sound refrigerant allows consumers to make a

responsible decision in the protection of the earth’s ozone layer.
As an Energy Star

r

Partner, Bryant Heating & Cooling Systems

has determined that this product meets the Energy Star

r

guidelines for energy efficiency. Refer to the combination ratings

in the Product Data for system combinations that meet Energy

Star

r

guidelines.

NOTE

:

Ratings contained in this document are subject to

change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.

INDUSTRY LEADING

FEATURES / BENEFITS

Efficiency

S

15 SEER/ 11.2 -- 13.0 EER/ 7.7 -- 8.8 HSPF (Nominal)

S

Microtube Technology

t

refrigeration system

S

Indoor air quality accessories available

Sound

S

Sound level as low as 70 dBA

Comfort

S

System supports Thermidistat

t

or standard thermostat

controls

Reliability

S

Puron

r

refrigerant -- environmentally sound, won’t

deplete the ozone layer and low lifetime service cost.

S

Front--seating service valves

S

Scroll compressor

S

Internal pressure relief valve

S

Internal thermal overload

S

High pressure switch

S

Loss of charge switch

S

Filter drier

S

Balanced refrigeration system for maximum reliability

Durability

DuraGuard

t

protection package:

S

Solid, durable sheet metal construction

S

Steel louver coil guard

S

Baked--on, complete outer coverage, powder paint

Applications

S

Long--line -- up to 250 feet (76.20 m) total equivalent length,
up to 200 feet (60.96 m) condenser above evaporator, or up to
80 ft. (24.38 m) evaporator above condenser (See Longline
Guide for more information.)

S

Low ambient (down to --20

_

F/--28.9

_

C) with accessory kit

Summary of Contents for 225A

Page 1: ...o date ratings information INDUSTRY LEADING FEATURES BENEFITS Efficiency S 15 SEER 11 2 13 0 EER 7 7 8 8 HSPF Nominal S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 70 dBA Comfort S System supports Thermidistatt or standard thermostat controls Reliability S Puronr refrigerant environmentally sound won t deplete the ozone layer ...

Page 2: ...w are critical to achieve rated capacity and efficiency Installation of this product should follow all manufacturing refrigerant charging and air flow instructions Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X 15 SEER X X X X X X X Scroll Compressor X X X X X X X L...

Page 3: ...ximum allowable total equivalent length is up to 250 ft 76 2 m The maximum vertical separation is 200 ft 60 96 m when outdoor unit is above indoor unit and up to 80 ft 24 38 m when the outdoor unit is below the indoor unit Refer to Accessory Usage Guideline below for required accessories See Longline Application Guideline for required piping and system modifications Also refer to the table below f...

Page 4: ...cludes Outdoor Air Temperature Sensor TSTATBBPHH01 B HybridHeatt Dual Fuel Thermostat Auto Changeover 7 Day Programmable F C Includes Outdoor Sensor TSTATXXSEN01 B TSTATBBPHP01 B Thermostat Auto Changeover 7 Day Programmable F C 2 Stage Heat 1 Stage Cool TSTATBBNHP01 C Thermostat Auto Changeover Non Programmable F C 2 Stage Heat 1 Stage Cool TSTATBBSHP01 Standard Programmable Thermostat Manual Cha...

Page 5: ...ff cycles Improves compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all commercial applications 5 Evaporator Freeze Thermostat An SPST temperature actuated switch that stops unit operation when evaporator reaches freeze up conditions Usage Guideline Required whe...

Page 6: ...to allow for drainage from unit base Usage Guideline Suggested in the following applications Heat pump installations in heavy snowfall areas Heat pump installations in snow drift locations Heat pump installations in areas of prolonged subfreezing temperatures All commercial installations 14 Sound Hood Wraparound sound reducing cover for the compressor Reduces the sound level by about 2 dBA Usage G...

Page 7: ...able tables of the NEC ANSI NFPA 70 Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2 Time Delay fuse FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTE Control circuit is 24 V on all units and requires external power source Copper wire must be used from service disconnect to unit All motors com...

Page 8: ...8 DIMENSIONS ENGLISH 225A ...

Page 9: ...9 DIMENSIONS SI 225A ...

Page 10: ...ANA060 FX4CN B F 060 225ANA048 FX4CN B F 060 225ANA042 FX4CN B F 048 225ANA036 FX4CN B F 042 225ANA030 FX4CN B F 036 225ANA024 FX4CNF030 225ANA018 FX4CNF018 BASED ON INDOOR ENT AIR AT 70ºF 21ºC AND AT RATED CFM 10 23 0 17 78 10 12 22 20 6 67 30 1 11 40 4 44 50 10 60 15 56 70 21 11 80 26 67 OUTDOOR TEMPERATURE ºF ºC 225A ...

Page 11: ...arious examples Wall Wall Wall Wall 24 Service 6 152 4 mm 24 609 6 Service 24 609 6 Service 24 609 6 Service 24 609 6 Service 24 609 6 24 609 6 24 609 6 12 304 8 12 304 8 12 304 8 12 304 8 6 152 4 Note Numbers in mm A07833 225A ...

Page 12: ...00 3 52 7 7 10100 2 32 3106440 225ANA018 B CSPH 2412A 353AAV036040 17700 12 0 15 0 17700 3 68 8 2 10200 2 38 3106441 225ANA018 B CSPH 2412A 353AAV036060 17500 12 0 15 0 17400 3 56 7 8 10100 2 32 3032807 225ANA018 B CSPH 2412A 355 A C AV042040 17400 11 7 14 8 17400 3 50 7 7 10100 2 30 3032808 225ANA018 B CSPH 2412A 355 A C AV042060 17400 11 7 14 8 17500 3 52 7 7 10100 2 30 3032809 225ANA018 B CSPH ...

Page 13: ...4400 2 60 3032841 225ANA024 B CNPV 3014A TDR 23400 11 2 13 5 24000 3 60 8 4 15300 2 52 3032845 225ANA024 B CNPV 3017A 315 A J AV048090 23400 12 8 15 5 23600 3 72 8 5 14400 2 64 3106451 225ANA024 B CNPV 3017A 353AAV036040 23800 12 5 15 5 23600 3 86 8 8 14600 2 70 3106452 225ANA024 B CNPV 3017A 353AAV036060 24000 12 5 15 5 23600 3 86 8 8 14700 2 72 3106453 225ANA024 B CNPV 3017A 353AAV036080 23800 1...

Page 14: ... 3 64 8 3 17400 2 50 3032948 225ANA030 B CNPH 3017A 315 A J AV036070 28800 12 5 15 5 29000 3 58 8 3 17300 2 48 3032949 225ANA030 B CNPH 3017A 315 A J AV048090 28800 13 0 15 5 29000 3 62 8 3 17200 2 50 3032950 225ANA030 B CNPH 3017A 315 A J AV060110 28800 13 0 15 5 29000 3 62 8 3 17200 2 50 3032951 225ANA030 B CNPH 3017A 315 A J AV066135 28800 13 0 15 5 29000 3 64 8 4 17200 2 50 3032952 225ANA030 B...

Page 15: ...42 3033013 225ANA030 B CSPH 3612A 313 AV048070 29600 12 5 15 5 29800 3 76 8 5 17600 2 54 3033014 225ANA030 B CSPH 3612A 313 AV048090 29600 13 0 15 5 29600 3 82 8 6 17500 2 58 3032985 225ANA030 B CSPH 3612A 315 A J AV036070 29200 13 0 15 5 29400 3 72 8 4 17400 2 54 3032986 225ANA030 B CSPH 3612A 315 A J AV048090 29400 13 0 16 0 29200 3 74 8 4 17300 2 56 3032987 225ANA030 B CSPH 3612A 315 A J AV0601...

Page 16: ...15 0 35000 3 54 8 2 21000 2 50 3033079 225ANA036 B CNPH 3617A 355 A C AV042080 34000 12 0 14 5 35200 3 50 8 0 21000 2 48 3033080 225ANA036 B CNPH 3617A 355 A C AV060080 34000 12 5 14 5 35000 3 54 8 2 21000 2 50 3033081 225ANA036 B CNPH 3617A 355 A C AV060100 34200 12 5 15 0 35000 3 54 8 2 21000 2 50 3033082 225ANA036 B CNPH 3617A 355 A C AV060120 34000 12 5 15 0 35000 3 54 8 2 20800 2 50 3033076 2...

Page 17: ...SPH 3612A 355 A C AV060120 35000 13 0 15 5 35400 3 70 8 2 21000 2 58 3033101 225ANA036 B CSPH 3612A TDR 35200 12 0 14 0 36000 3 70 8 2 22200 2 52 3033039 225ANA036 B CSPH 4212A 313 AV024045 35200 12 0 14 5 36000 3 72 8 4 21600 2 54 3033040 225ANA036 B CSPH 4212A 313 AV048070 35200 12 5 15 0 36000 3 76 8 5 21400 2 58 3033041 225ANA036 B CSPH 4212A 313 AV048090 35600 13 0 15 5 35800 3 84 8 6 21200 2...

Page 18: ...3 64 8 2 25200 2 62 3033215 225ANA042 B CNPH 4221A 315 A J AV066155 41500 12 5 15 0 41000 3 62 8 2 25200 2 62 3106553 225ANA042 B CNPH 4221A 353AAV036040 41500 12 0 14 5 42000 3 58 8 3 25800 2 58 3106554 225ANA042 B CNPH 4221A 353AAV036060 41500 12 0 14 5 42000 3 58 8 3 25800 2 56 3106555 225ANA042 B CNPH 4221A 353AAV036080 41500 12 0 14 5 42000 3 58 8 3 25800 2 58 3106556 225ANA042 B CNPH 4221A 3...

Page 19: ...15 0 42000 3 70 8 2 25600 2 64 3106565 225ANA042 B CSPH 4212A 353AAV036040 42000 12 5 15 0 42000 3 72 8 6 26000 2 62 3106566 225ANA042 B CSPH 4212A 353AAV036060 42000 12 5 15 0 42000 3 70 8 5 26000 2 62 3106567 225ANA042 B CSPH 4212A 353AAV036080 42000 12 5 15 0 42000 3 70 8 5 26000 2 62 3106568 225ANA042 B CSPH 4212A 353AAV048080 42000 12 5 15 0 42000 3 68 8 5 25800 2 62 3106569 225ANA042 B CSPH ...

Page 20: ...600 2 52 3033300 225ANA048 B CNPH 4821A 315 A J AV066155 46500 12 5 15 0 45000 3 60 8 2 28400 2 54 3106591 225ANA048 B CNPH 4821A 353AAV048080 46500 11 5 14 0 45500 3 56 8 2 29000 2 50 3106592 225ANA048 B CNPH 4821A 353AAV060100 46500 12 0 14 5 45000 3 60 8 2 28600 2 54 3106593 225ANA048 B CNPH 4821A 353AAV060120 46500 12 0 14 5 45000 3 62 8 2 28600 2 54 3033294 225ANA048 B CNPH 4821A 355 A C AV06...

Page 21: ...60 B CAP 6021A TDR 56500 11 2 13 5 57500 3 64 8 3 35800 2 56 3033377 225ANA060 B CAP 6024A 313 AV060135 56500 11 5 14 0 57000 3 62 8 4 35400 2 58 3033359 225ANA060 B CAP 6024A 315 A J AV066135 56500 11 5 14 0 57000 3 66 8 3 35400 2 60 3033360 225ANA060 B CAP 6024A 315 A J AV066155 57000 12 0 14 0 57000 3 70 8 4 35200 2 62 3106604 225ANA060 B CAP 6024A 353AAV060120 56500 11 8 14 0 56500 3 66 8 5 35...

Page 22: ... 64 1 14 18 74 14 22 1 30 17 67 13 79 1 49 16 65 13 38 1 70 15 78 13 03 1 90 15 10 12 76 2 05 63 17 2 18 30 14 08 1 15 17 31 13 64 1 32 16 31 13 21 1 51 15 34 12 79 1 72 14 53 12 44 1 91 13 89 12 16 2 05 62 16 7 18 05 17 89 1 15 17 20 17 20 1 32 16 39 16 39 1 51 15 61 15 61 1 71 14 94 14 94 1 91 14 41 14 41 2 05 57 13 9 17 99 17 99 1 15 17 20 17 20 1 32 16 39 16 39 1 51 15 61 15 61 1 71 14 94 14 9...

Page 23: ...0 98 315 A J AV036070 CNPH 2417A 0 97 1 01 315 A J AV036070 CNPH 3017A 0 98 0 98 315 A J AV036070 CNPV 2414A 0 97 1 01 315 A J AV036070 CNPV 3014A 0 98 0 98 315 A J AV036070 CSPH 2412A 0 98 0 98 315 A J AV036070 CSPH 3012A 0 99 0 99 315 A J AV036070 CAP 2417A 0 97 0 97 315 A J AV048090 CAP 3017A 0 99 0 97 315 A J AV048090 CNPH 2417A 0 97 0 97 315 A J AV048090 COOLING INDOOR MODEL CAPACITY POWER FU...

Page 24: ...120 CSPH 3012A 0 99 0 99 355 A C AV060120 CAP 2414A 0 98 1 02 313 AV024045 CAP 3014A 0 99 0 99 313 AV024045 CNPH 2417A 0 97 1 02 313 AV024045 CNPH 3017A 1 00 1 00 313 AV024045 CNPV 2414A 0 97 1 02 313 AV024045 CNPV 3014A 0 99 0 99 313 AV024045 CSPH 2412A 0 98 0 98 313 AV024045 CSPH 3012A 1 00 1 00 313 AV024045 See note on pg 26 225A ...

Page 25: ...NPV 3621A 0 99 1 07 CSPH 3012A 0 99 1 08 CSPH 3612A 1 01 1 08 CAP 3014A 0 98 0 98 315 A J AV036070 CAP 3614A 0 99 0 99 315 A J AV036070 CNPH 3017A 0 99 0 99 315 A J AV036070 CNPH 3617A 0 99 0 96 315 A J AV036070 CNPV 3014A 0 98 0 98 315 A J AV036070 CSPH 3012A 0 99 0 99 315 A J AV036070 CSPH 3612A 1 00 0 96 315 A J AV036070 CAP 3017A 0 99 0 95 315 A J AV048090 COOLING INDOOR MODEL CAPACITY POWER F...

Page 26: ...100 CNPH 3617A 0 99 0 96 355 A C AV060100 CNPV 3621A 0 99 0 96 355 A C AV060100 CSPH 3012A 0 99 0 96 355 A C AV060100 CSPH 3612A 1 01 0 97 355 A C AV060100 CNPH 3017A 0 99 0 95 355 A C AV060120 CNPH 3617A 0 99 0 95 355 A C AV060120 CSPH 3012A 0 99 0 95 355 A C AV060120 CSPH 3612A 1 00 0 96 355 A C AV060120 CAP 3017A 0 97 0 97 313 AV048070 CAP 3617A 0 99 0 99 313 AV048070 CNPH 3017A 0 99 0 99 313 A...

Page 27: ... 3621A 0 97 1 10 CNPV 4217A 0 99 1 09 CNPV 4221A 0 98 1 09 CSPH 3612A 0 99 1 05 CSPH 4212A 1 00 1 06 CAP 3614A 0 96 1 02 315 A J AV036070 CNPH 3617A 0 96 1 02 315 A J AV036070 CNPH 4221A 0 98 0 99 315 A J AV036070 CSPH 3612A 0 98 1 00 315 A J AV036070 CSPH 4212A 0 99 1 00 315 A J AV036070 CAP 3617A 0 97 0 97 315 A J AV048090 CNPH 3617A 0 97 0 97 315 A J AV048090 COOLING INDOOR MODEL CAPACITY POWER...

Page 28: ... 98 0 95 355 A C AV060100 CSPH 3612A 0 99 1 00 355 A C AV060100 CSPH 4212A 0 99 0 97 355 A C AV060100 CAP 4224A 0 97 0 97 355 A C AV060120 CNPH 3617A 0 96 0 98 355 A C AV060120 CNPH 4221A 0 98 0 95 355 A C AV060120 CSPH 3612A 0 99 0 97 355 A C AV060120 CSPH 4212A 0 99 0 97 355 A C AV060120 CAP 3614A 0 96 1 06 313 AV024045 CNPH 3617A 0 96 1 06 313 AV024045 CNPH 4221A 0 97 1 07 313 AV024045 CSPH 361...

Page 29: ... 13 CSPH 4812A 1 00 1 13 CNPH 4221A 0 99 1 07 315 A J AV036070 CNPH 4821A 1 00 1 08 315 A J AV036070 CSPH 4212A 1 00 1 08 315 A J AV036070 CSPH 4812A 1 00 1 08 315 A J AV036070 CAP 4817A 1 00 1 04 315 A J AV048090 CNPH 4221A 0 99 1 03 315 A J AV048090 CNPH 4821A 1 00 1 04 315 A J AV048090 CNPV 4217A 1 00 1 08 315 A J AV048090 CSPH 4212A 1 00 1 04 315 A J AV048090 CSPH 4812A 1 00 1 04 315 A J AV048...

Page 30: ...A 0 99 1 03 355 A C AV060100 CNPV 4821A 1 00 1 04 355 A C AV060100 CSPH 4212A 1 00 1 04 355 A C AV060100 CSPH 4812A 1 00 1 04 355 A C AV060100 CAP 4224A 0 98 1 06 355 A C AV060120 CAP 4824A 1 00 1 04 355 A C AV060120 CNPH 4221A 0 99 1 03 355 A C AV060120 CNPH 4821A 1 00 1 04 355 A C AV060120 CNPV 4824A 1 00 1 04 355 A C AV060120 CSPH 4212A 1 00 1 04 355 A C AV060120 CSPH 4812A 1 00 1 04 355 A C AV...

Page 31: ...0 98 1 02 315 A J AV048090 CSPH 4812A 0 97 1 01 315 A J AV048090 CSPH 6012A 0 99 1 03 315 A J AV048090 CAP 4821A 0 96 1 00 315 A J AV060110 CAP 6021A 0 99 0 99 315 A J AV060110 CNPH 4821A 0 96 1 00 315 A J AV060110 CNPH 6024A 0 98 0 98 315 A J AV060110 CNPV 4821A 0 96 1 00 315 A J AV060110 CSPH 4812A 0 97 1 01 315 A J AV060110 CSPH 6012A 0 99 0 99 315 A J AV060110 CAP 4824A 0 96 1 00 315 A J AV066...

Page 32: ...V 4821A 0 97 1 01 313 AV060110 CSPH 4812A 0 97 1 01 313 AV060110 CSPH 6012A 0 99 0 99 313 AV060110 CAP 4824A 0 97 1 01 313 AV060135 CAP 6024A 0 99 1 03 313 AV060135 CNPH 4821A 0 97 1 01 313 AV060135 CNPH 6024A 0 99 0 99 313 AV060135 CNPV 4824A 0 97 1 01 313 AV060135 CNPV 6024A 0 99 0 99 313 AV060135 CSPH 4812A 0 97 1 01 313 AV060135 CSPH 6012A 0 99 0 99 313 AV060135 See note on pg 26 225A ...

Page 33: ... 80 5 35 48 70 48 70 5 89 45 32 45 32 6 47 57 13 9 59 79 59 79 3 99 57 30 57 30 4 40 54 64 54 64 4 85 51 80 51 80 5 35 48 71 48 71 5 89 45 32 45 32 6 47 COOLING INDOOR MODEL CAPACITY POWER FURNACE MODEL FX4CN B F 060 1 00 1 00 FE4ANB006 1 00 1 00 FV4BNB006 1 00 1 00 FY4ANB060 0 99 1 06 CAP 6021A 0 98 1 05 CAP 6024A 0 98 1 05 CNPH 6024A 0 98 1 05 CNPV 6024A 0 98 1 05 CSPH 6012A 0 99 1 06 CAP 6021A ...

Page 34: ...1 18 7 70 7 07 1 23 9 77 8 91 1 29 12 01 10 66 1 35 14 50 13 20 1 42 17 32 17 32 1 51 20 39 20 39 1 61 23 82 23 82 1 74 675 5 83 5 36 1 18 7 81 7 18 1 23 9 91 9 03 1 28 12 16 10 80 1 33 14 72 13 39 1 40 17 57 17 57 1 48 20 69 20 69 1 58 24 18 24 18 1 70 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL FX4CNF018 1 00 1 00 FE4ANF002 0 99 0 97 FF1ENP018 1 02 1 08 FF1ENP024 1 02 1 06 FV4BNF002 0 99 0...

Page 35: ... 04 315 A J AV048090 CNPH 3017A 0 98 1 02 315 A J AV048090 CNPV 2417A 1 00 1 04 315 A J AV048090 CNPV 3017A 0 98 1 02 315 A J AV048090 CSPH 2412A 1 00 1 03 315 A J AV048090 CSPH 3012A 0 98 1 02 315 A J AV048090 CNPH 2417A 1 00 1 04 315 A J AV060110 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL CNPH 3017A 0 98 1 02 315 A J AV060110 CSPH 2412A 1 00 1 03 315 A J AV060110 CSPH 3012A 0 98 1 03 315 ...

Page 36: ...48090 CNPV 3617A 0 97 0 99 315 A J AV048090 CSPH 3012A 0 97 0 99 315 A J AV048090 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL CSPH 3612A 0 97 0 96 315 A J AV048090 CAP 3621A 0 97 0 98 315 A J AV060110 CNPH 3017A 0 97 0 99 315 A J AV060110 CNPH 3617A 0 97 0 99 315 A J AV060110 CNPV 3621A 0 97 0 99 315 A J AV060110 CSPH 3012A 0 97 0 99 315 A J AV060110 CSPH 3612A 0 98 0 97 315 A J AV060110 CNP...

Page 37: ...99 313 AV048070 CNPH 3017A 0 98 1 00 313 AV048070 CNPH 3617A 0 98 1 00 313 AV048070 CNPV 3017A 0 98 1 00 313 AV048070 CNPV 3617A 0 98 1 00 313 AV048070 CSPH 3012A 0 98 1 01 313 AV048070 CSPH 3612A 0 99 0 98 313 AV048070 CAP 3621A 0 98 0 97 313 AV048090 CNPH 3017A 0 97 0 99 313 AV048090 CNPH 3617A 0 97 0 99 313 AV048090 CNPV 3621A 0 97 0 99 313 AV048090 CSPH 3012A 0 97 0 99 313 AV048090 CSPH 3612A ...

Page 38: ...J AV048090 CSPH 4212A 0 98 0 99 315 A J AV048090 CAP 3621A 0 97 1 02 315 A J AV060110 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL CAP 4221A 0 98 1 01 315 A J AV060110 CNPH 3617A 0 97 1 03 315 A J AV060110 CNPH 4221A 0 97 0 99 315 A J AV060110 CNPV 3621A 0 97 1 03 315 A J AV060110 CNPV 4221A 0 97 0 99 315 A J AV060110 CSPH 3612A 0 98 1 00 315 A J AV060110 CSPH 4212A 0 99 0 99 315 A J AV060110...

Page 39: ...7A 0 99 1 07 313 AV024045 CNPH 4221A 0 99 1 05 313 AV024045 CSPH 3612A 1 00 1 03 313 AV024045 CSPH 4212A 1 00 1 02 313 AV024045 CAP 3617A 0 98 1 04 313 AV048070 CNPH 3617A 0 98 1 06 313 AV048070 CNPH 4221A 0 99 1 03 313 AV048070 CNPV 3617A 0 98 1 06 313 AV048070 CNPV 4217A 0 99 1 02 313 AV048070 CSPH 3612A 0 99 1 02 313 AV048070 CSPH 4212A 1 00 1 01 313 AV048070 CAP 3621A 0 98 1 01 313 AV048090 CA...

Page 40: ...J AV060110 CNPH 4821A 1 00 1 04 315 A J AV060110 CNPV 4221A 0 99 1 05 315 A J AV060110 CNPV 4821A 1 00 1 04 315 A J AV060110 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL CSPH 4212A 1 00 1 04 315 A J AV060110 CSPH 4812A 1 00 1 04 315 A J AV060110 CAP 4224A 0 99 1 06 315 A J AV066135 CAP 4824A 1 00 1 04 315 A J AV066135 CNPH 4221A 0 98 1 03 315 A J AV066135 CNPH 4821A 1 00 1 03 315 A J AV066135...

Page 41: ...SPH 4212A 1 00 1 05 355 A C AV060120 CSPH 4812A 1 00 1 04 355 A C AV060120 CAP 4817A 1 00 1 05 313 AV048070 CNPH 4221A 1 00 1 10 313 AV048070 CNPH 4821A 1 00 1 05 313 AV048070 CNPV 4217A 1 00 1 08 313 AV048070 CSPH 4212A 1 00 1 06 313 AV048070 CSPH 4812A 1 00 1 05 313 AV048070 CAP 4221A 0 99 1 06 313 AV048090 CAP 4821A 1 00 1 03 313 AV048090 CNPH 4221A 0 99 1 06 313 AV048090 CNPH 4821A 1 00 1 03 3...

Page 42: ...AV060110 CAP 4824A 0 97 1 05 315 A J AV066135 CAP 6024A 0 97 1 03 315 A J AV066135 CNPH 4821A 0 97 1 05 315 A J AV066135 CNPH 6024A 0 97 1 03 315 A J AV066135 CNPV 4824A 0 97 1 05 315 A J AV066135 CNPV 6024A 0 97 1 03 315 A J AV066135 CSPH 4812A 0 97 1 04 315 A J AV066135 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL CSPH 6012A 0 97 1 02 315 A J AV066135 CAP 4824A 0 97 1 04 315 A J AV066155 CA...

Page 43: ...4 56 84 4 46 66 32 66 32 4 65 75 63 75 63 4 90 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL FX4CN B F 060 1 00 1 00 FE4ANB006 1 00 1 00 FV4BNB006 1 00 1 00 FY4ANB060 1 02 1 07 CAP 6021A 1 01 1 06 CAP 6024A 1 01 1 06 CNPH 6024A 1 01 1 07 CNPV 6024A 1 01 1 07 CSPH 6012A 1 01 1 05 CAP 6021A 1 00 1 05 315 A J AV060110 CNPH 6024A 1 00 1 06 315 A J AV060110 CSPH 6012A 1 01 1 05 315 A J AV060110 CAP...

Page 44: ...n resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped with steel wire safety guards Compressor Compressor will be hermetically sealed Compressor will be mounted on rubber vibration isolators Condenser Coil Condenser coil will be air cooled Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned dehydr...

Reviews: