A small hot fire is more efficient and safer than a large smoldering one.  During rela-

tively warm weather, add only enough wood so that the fire will burn out in a desired time.  
If  the  building  becomes  too  hot,  simply  open  a  window.    Do  not  unplug  the  furnace  or 
block the furnace air flow. 
 

As  your fire burns down, the fan will begin to cycle on and off as it moves the heated 

air  out  and  the  fan  control  thermostat  is  cooled.    If  you  desire  to  run  the  fan  below  the 
thermostat temperature range(+90º F ), turn the fan control switch (the toggle switch un-
der the fan enclosure box) to the “on” position. This will cause the fan to run continuously 
whether there is heat in the furnace or not. 
 

After a week of 10 to 12 hour burns, open the loading door slightly and allow the fire 

to burn hot for 15 to 20 minutes while in attendance. This will help minimize creosote or 
soot buildup. 
 

Combustion air must be available above the fuel bed.  Try to stack logs so that air 

can circulate between them. 
 

Loading  and  ash  doors  must  be  kept  tightly  closed  and  gaskets  in  good  condition.  

Inspect the furnace in the dark for light showing around the door.  Door gaskets need to be 
inspected continuously and replaced when showing sign of wear. 
 

A small portable generator or inverter of sufficient amperage can be used to oper-

ate the furnace during an extended power out-
age.  Do not operate the furnace without elec-
tric power. 
 

INSTALLATION INSTRUCTIONS 

Please read completely before starting. 

 
NOTICE TO OUR CUSTOMERS:  Your  Bryan 
Furnace is absolutely the safest, cleanest solid fuel furnace system available.  Your furnace 
has been assembled from the finest materials available by skilled craftsmen under the su-
pervision  of  a  strict  quality  control  program.  Bryan  Furnace  Works  Inc,  however  has  no 
control over the handling of your furnace during shipment or installation.  The possibility 
does exist, however remote, that a broken seal will allow some smoke or fumes into the 
home.  If the possibility of smoke or fumes in the house is unacceptable, do not install this 
furnace.    Keep  in  mind  that  smoke  in  the  home  is  a  certainty  with  a  fireplace  or  indoor 
heater. 

GENERAL NOTES 

 

The air from a solid fuel appliance is considerably hotter than from gas, oil or elec-

tric furnaces. Do not connect this furnace to anything other than METAL ductwork.  
 

Both hot and cold air ducts  must be insulated outdoors with insulation at least 1” in 

thickness and have a waterproof covering. In addition, the hot air duct must be insulated 

for its entire length.  There must be a minimum of 2” clearance between the hot air duct 
and any flammable surface. 
 Supply  air  can  reach  temperature  of  250°  F  under  certain  conditions,  i.e.  loading  or  ash 
door left open, leak in combustion chamber, faulty indoor thermostat or hi-limit switch. 
 

Debris like plastic, paper, dry grass or any flammable materials can ignite if  it comes 

in contact with exposed hot air duct. 
 

Never connect The Bryan Furnace to a chimney serving another appliance.              6 

                 Warning 

The installation of this unit must comply 
with state and local requirements and be 
 inspected by the state or local inspector, 

 if required. 

Summary of Contents for 450

Page 1: ...779 1616 TOLL FREE 1 800 927 9947 FAX 979 822 0540 All installations must be in accor dance with local and state codes which may differ from this man ual SAVE THESE INSTRUCTIONS FIRE BOX BUILT FROM 3 16 STEEL PLATE ALL WELDED CONSTRUCTION WITH CAST IRON GRATES EXTERIOR COVERING BUILT FROM 1 16 INCH GALVNIZED PLATE CAST IRON DOORS FRAMES GRATES AND DOOR LATCHES P N 3000 002 ...

Page 2: ...ing your Bryan Furnace Check with your local building officials to be in con formance with local building plumbing and electrical codes These instructions can help you now as well as in the future and should be retained for your refer ence If after installing your Bryan Furnace you encounter a situation that you are not comfortable with feel free to call our toll free number 1 800 927 9947 and ask...

Page 3: ... Group 10 Shelter Group 11 Firebox Brick and Grates 12 Door Assemblies 13 Wiring Diagram Model 450 14 Electrical System 15 Supplies 16 INSPECTION AND CARE Periodic Inspections 17 Adjusting Door Handles 17 Replacing Door Gaskets 17 Resealing Door Frame 17 WARRANTY 18 OPERATING INSTRUCTIONS PAGE How itWorks 4 Operation 4 Building a Fire 4 Temperature Adjustments 5 Creosote and Soot Formation and the...

Page 4: ...ce required for refueling and ash removal Firewood varies greatly in quality due to species and moisture content Wood that is seasoned and dry greatly improves the efficiency of the furnace Wood of over 20 moisture will not burn well Pine and some other softwoods burn very quickly with high creosote production and very few coals These woods are best used to start hardwood fires BUILDING A FIRE Pla...

Page 5: ...ws uncontrolled combustion air to enter the chamber and can cause overheating NEVER leave the ash door open with a hot fire going as this can cause the grates to warp CREOSOTE AND SOOT FORMATION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapors which com bined with expelled moisture may form creosote The creosote vapors condense in the relatively cool chimney...

Page 6: ... completely before starting NOTICE TO OUR CUSTOMERS Your Bryan Furnace is absolutely the safest cleanest solid fuel furnace system available Your furnace has been assembled from the finest materials available by skilled craftsmen under the su pervision of a strict quality control program Bryan Furnace Works Inc however has no control over the handling of your furnace during shipment or installatio...

Page 7: ...rnace must be grounded either through the electric cord third prong or by driving a copper coated steel rod 6 six feet into the ground and attaching it to the base of the furnace with a 14 gauge copper wire Also install the provided thermo stat at a desired location inside the heated area preferably near the return air You will need to provide required thermostat wire from the thermostat to the we...

Page 8: ...ivered down stream from the central system Run the return air duct separate from the return air from your central system or the hot air from The Bryan Furnace may try to short circuit back through the central system NEW DUCTWORK SYSTEM If possible run your ductwork under the floor to deliver heat at floor level or into the attic where you can locate outlets at an area of your choice With the Model...

Page 9: ...insulate Improper installation Review installation instructions Check for hot air leaks in ductwork Excessive creosote or Use of green or wet Use seasoned dry wood or burn smaller soot build up in stack wood charges hotter Burning softwoods with Avoid using if possible If you must high resin content burn them burn small charges hotter Poor draft See above Smoke or fumes from Normal for new furnace...

Page 10: ... 5 1000 015 Thermometer 1 6 2000 050 Galvanized Door Frame 1 2000 037 Insulation Set 1 2000 048 10 Galvanized Collar 1 Key Part Description Qty 7 2000 059 Removable Panel 1 8 1000 003 Starter Collar 1 9 1000 012 Fan Indicator Light 1 10 1000 023 Comb Air Intake 1 11 1000 009 Motion Detecting Light 1 12 2000 044 Adaptor Plate 1 1000 028 Stack Seal Rope 1 2000 032 Inside Enclosure 1 ...

Page 11: ...er Chute 2 4 1000 017 Serial No ID Tag 1 5 2000 028 Ash Pan 1 6 1000 024 Elect Supply J Box 1 7 2000 026 Poker 1 8 1000 015 Thermostat Probe 1 9 1000 002 Frame Door Main 1 10 2000 011 Baffle Plate 1 11 1000 001 Door Main 1 12 903 042 Fire Brick 1 inch 30 13 904 048 Grates Cast Iron 4 14 2000 024 Front Bridge Brick 1 15 950 1400 Fire Brick Tapered 10 16 904 043 Frame Ash Door 1 17 904 042 Door Ash ...

Page 12: ...ion Chamber 1 3 2000 018 Combustion Air Pipe Assembly 1 4 2000 000 Base Pan 1 Key Part Description Qty 1 2000 025 Rear Brick 1 2 2000 026 Poker 1 3 904 048 Grate 4 4 903 041 Fire Brick 1 30 Key Part Description Qty 5 2000 024 Front Brick 1 6 2000 015 S S Grate Support 2 7 903 042 Fire Brick Tapered 10 8 2000 028 Ash Pan Steel 1 12 ...

Page 13: ...2 006 A D Hinge Pin 1 Key Part Description Qty 5 1000 002 Door Frame 1 6 1000 029 Door Gasket 54 1 7 904 043 Ash Door Frame 1 8 950 1351 Ash Door Gasket 1 Key Part Description Qty 1 960 1350 Door Handle Assembly 1 2 103 024 5 16 Lock Nut 1 3 103 015 5 16 Lock Washer 1 4 904 041 Door Latch 1 5 101 000 Comp Washer 1 6 960 1349 Handle Rod Button 1 7 904 073 Wire Spring Grip 1 ...

Page 14: ...14 WIRING DIAGRAM MODEL 450 14 ...

Page 15: ... 35 Amp 1 1000 005 Room Thermostat 1 1000 006 Transformer 24 Volt 1 1000 008 Relay 1 1000 009 Motion Detector Light 1 1000 010 Weatherproof Junction Box 2 1000 012 Fan Indicating Light 2 1000 016 Plastic Flex Wire Shield 8 ft 604 022 Wiring Harness 1 1000 024 4 X 4 Junction Box 2 604 023 Power Cord SJO 8 ft 1 603 013 3 8 Heyco Straight Fittings 6 1000 027 Romex Clamps 2 603 011 3 8 Liquatite Condu...

Page 16: ...ll Screw 101 002 10 X Self Drill Screw 111 016 1 8 Stainless Steel Rivet 908 014 Refractory Cement Pint 908 013 Silicone Sealer Aluminum 10 oz 908 001 Door Gasket Cement 3 oz 908 002 Door Gasket Cement 11 oz 903 017 Door Gasket 5 5 Bulk 921 022 Cold Galvanize Paint 16 oz 921 015 Black Spray Paint 16 oz 3000 002 Owners Parts Manual Model 1000 000 1 Insulation Sq Ft 1000 030 Caution Labels Set 1000 ...

Page 17: ... and will allow for a tighter fit REPLACING DOOR GASKET 1 Remove door from unit 2 Remove old gasket from channel and clean old glue rust from channel 3 Apply an even film of high temperature adhesive all the way around channel Note Do not start the gasket on the corner as the gasket may need to be pulled or pushed back to make fit Make sure gasket is even all the way around door 4 Apply adhesive t...

Page 18: ... inspection of unit to insure all parts and workmanship are satis factory the following parts are not warranted A Cast iron grates B Door gasket and latches C Fire Brick and front and rear refractory 7 Claims shall be made under this warranty by written notice to Manufacturer s lo cal distributor If the service is not covered by this warranty purchaser shall pay for all related labor and material ...

Page 19: ...19 MODEL 450 MODEL 300 MODEL 350 ...

Page 20: ...and has con tinued to build furnaces through the pre sent time at our facility Rik Mar Inc also manufactures scientific animal cages which are shipped world wide The cages are shipped to hospitals universities research facilities and zoos Rik Mar s operation consists of 30 000 sq ft of manufacturing facilities and main tains a work force of approximately fif teen full time employees The Bryan Fur ...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ...23 ...

Reviews: