background image

CARE INSTRUCTIONS

Careful and proper cleaning of the surfaces of your ray table is particularly important to keep it in optimum condition. 

The following cleaning instructions are only intended as a recommendation. Brunner GmbH will not be held liable for 

damage to the finish caused by improper cleaning.

Cleaning the aluminium frame

For normal use, it is sufficient to wipe the metal surfaces with a clean, dry dust cloth. Any particularly dirty areas can be 

cleaned with a standard, grease-dissolving all-purpose cleaner. Tarnished areas on the polished surface can be polished up 

with chrome polish. Never use abrasive cleaning agents, as well as toilet or sanitary cleaners. The gliders' surfaces should be 

regularly cleaned of coarse pieces of dirt or deposits.

Cleaning the powder-coated under-frame

For normal use, it is sufficient to wipe the powder-coated surfaces with a clean, soft, slightly damp cloth. Any particularly 

dirty areas can be cleaned with a standard, grease-dissolving all-purpose cleaner. However, abrasive cleaning agents and 

WC or sanitary cleaners must not be used because they may damage the powder-coated surface. Acid or alkaline cleaning 

agents and organic solvents must also not be used. Please only use soft cotton cloths for cleaning purposes and never use 

plastic sponges, wire wool or steam jet devices, which could permanently damage the surface. The gliders' surfaces should 

be regularly cleaned to remove coarse pieces of dirt or deposits.

Electrification and cabling | Care instructions

       16 . 17

Summary of Contents for ray

Page 1: ...ray table Assembly instructions Design jehs laub...

Page 2: ......

Page 3: ...nge of uses and offer the right model and features for every need The individual table components can be quickly and easily connected Cable channels that can be folded down and removed without tools e...

Page 4: ......

Page 5: ...Design of a table with individual legs Design of a table with system legs Notes for assembly General notes for setup Assembly tools for ray table Assembly instructions Assembly of a table with fixed i...

Page 6: ...nts of an individual leg table for small table top sizes and without electrification options The second drawing shows the structure of a conference table system with a cable channel and additional ele...

Page 7: ...le legs 120 x 120 cm 9310 9 Arch 9330 9 Plectrum 130 x 130 cm 120 cm side length 3 table legs Conference table system with visible traverse under frame and system feet Model 9312 Table top shapes 9312...

Page 8: ...he variants of the 9310 model have an individual leg that is mounted onto the table top on site Design of a table with system legs The variants of the 9312 model have a system leg with a visible trave...

Page 9: ...and designs The assembly tools suggested are simply recommendations from Brunner GmbH Only the materials supplied may be used for assembly Brunner GmbH accepts no liability for damage caused during a...

Page 10: ...und with the table surface facing down preferably on a soft layer such as a blanket to prevent scratches Position the holes of the legs on the holes of the table top and align the leg correctly For ea...

Page 11: ...the connector peg on the upper end of the leg into the designated recess in the visible traverse under frame intended Screw in and tighten two of the M10 screws included in delivery using the size 6...

Page 12: ...g four M6x20 screws each a size 4 hexagon spanner and a torque of approx 5 Nm ASSEMBLY STEP 4 Realign the table top precisely and begin attaching the two outer screw on points per table end as explain...

Page 13: ...d fold the other end of the plastic part down toward the table top Slide the plastic bracket within the rail so that the screw on point is centred over the screw socket Now fasten the plastic bracket...

Page 14: ...ASSEMBLY INSTRUCTIONS ASSEMBLY STEP 6 Once you have repeated the process for all screw on points tighten the screws one after another...

Page 15: ...arious profile boxes to choose from as well If you have decided to purchase an accompanying profile box it is delivered premounted onto the cable channel Guiding cables horizontally using a cable chan...

Page 16: ...bles are clipped in on the inside of the plastic clip one after another Guiding cables vertically The cables can be guided to the floor completely out of sight using a groove in the table leg The groo...

Page 17: ...itary cleaners The gliders surfaces should be regularly cleaned of coarse pieces of dirt or deposits Cleaning the powder coated under frame For normal use it is sufficient to wipe the powder coated su...

Page 18: ...With normal use it is enough to remove dirt from the surface once or twice a year with a damp cloth Use water mixed with a small amount of commercially available mild detergent to damp en the cloth T...

Page 19: ...right to technical changes errors and colour deviations Some models are displayed as special versions that are subject to additional costs Imprint Product design jehs laub Illustrations Claas Ratjen B...

Page 20: ...06 2017 www brunner group com Brunner GmbH 2017 Im Salmenkopf 10 77866 Rheinau Germany T 49 78 44 40 20 F 49 78 44 40 28 00 info brunner group com...

Reviews: