22
Operating Instructions (1.14)
© 2017 Brunner GmbH
damper flap (if mounted) opens completely.The sensor at the exhaust
gas stub announces the combustion temperature. Make sure that the lev-
el of ashes is not too high. Maximum level: 5 cm below the door frame.
Load some chopped firewood loosely into the fireplace. Load the desired
amount of wood logs on this small wood. Put a good fire-starter, such as
Fidibus between the logs and light the fire. Fire-starters are practical fire
starting aids. Please note: big logs are not easy to light and heavy to burn
in a cold fireplace.Never use petrol or alcohol as aids for lighting fire!
Close the firing door. From now on the EAS takes over the control of the
combustion air valve/damper flap. Closing the door is the signal for the
EAS that a heating procedure is started. The diagram for "Stage 1" ap-
pears. In this position the air valve is fully opened, so that a fast high
heating is possible. The fast high heating is the most important factor in
order to obtain a clean combustion with reduced emissions. Until approx.
450°C (depending on the type of heater) is reached, the combustion air
valve remains in this stage. With exceeding of this threshold temperature
the motor of the combustion air valve drives the air valve further stage
for stage.The damper flap will be activated as needed by the EAS If this
threshold temperature is not reached, the message “Heating error” ap-
pears.