LDSBus Isolated IO Controller Datasheet 

Version 1.1 

 

Document Reference No.: BRTSYS_000009    Clearance No.: BRTSYS#005 

 

 

Copyright © BRT Systems Pte Ltd 

16 

 

Appendix A 

 References 

 
Document References 

 

BRTSYS_AN_001_LDSBus_Configuration_Utility_User_Guide

 

 

Acronyms and Abbreviations 

 

Terms 

Description 

AC 

Alternating Current 

AWG 

American Wire Gauges 

DC 

Direct Current 

IoT 

Internet of Things 

LED 

Light Emitting Diode 

LDSBus 

Long Distance Sensor Bus 

Summary of Contents for LDSBus LA120101A

Page 1: ...3R LDSBus Isolated IO Controller Datasheet The LDSBus Isolated IO Controller offers 2 isolated channels of digital and analog inputs and a variety of associated power source options to achieve 3 3V 5V...

Page 2: ...roller Datasheet Version 1 1 Document Reference No BRTSYS_000009 Clearance No BRTSYS 005 Copyright BRT Systems Pte Ltd 2 2 Part Numbers Part Naming LC060101A LDSBus Isolated IO Controller LA120101A LD...

Page 3: ...n 6 6 Mounting Options 7 6 1 Flush Mount 7 6 2 DIN Rail Mount 7 7 Terminal Wiring Instructions 8 7 1 Isolated IO Digital INPUT Setup 9 7 2 Isolated IO Digital OUTPUT Setup 10 7 3 Isolated Analog INPUT...

Page 4: ...e 0V 10V Analog Output resolution 10mV Analog Output Accuracy Typical 3 For 0V 1V Accuracy 10mV typical Digital IO Input Number of Channels 2 Digital Input Voltage 1 8VDC 12VDC refer to external power...

Page 5: ...005 Copyright BRT Systems Pte Ltd 5 4 Hardware Features Figure 1 LDSBus Isolated IO Controller 2 CH Digital IO Output Output Power Digital IO Power Output Power 2 CH Analog Input 2 CH Analog Output O...

Page 6: ...Figure 2 illustrates the connection of the LDSBus Isolated IO Controller LDSBus Device to the LDSBus Please visit https brtsys com resources to view the full device application setup and installation...

Page 7: ...er can be flush mounted directly on a wall or any flat surface using 2 M3 5 16mm thread screws Figure 3 LDSBus Isolated IO Controller Flush Mount 6 2 DIN Rail Mount The LDSBus Isolated IO Controller c...

Page 8: ...e direction To release the wire turn the handle in an anticlockwise direction Figure 5 Clamping wire with screwdriver in clockwise direction Table 2 provides a list of American Wire Gauges AWGs that c...

Page 9: ...different configurations IO Digital Input with 5V Application IO Digital Input with External Pull up Use AWG 26 16 The RED wire indicates that it comes from an external IO source Connect to the IN1 o...

Page 10: ...o 12V The two options for connecting are as follows Digital Output with 5V Application Digital Output with External Source Use AWG 26 16 The BLACK wire connects to on board GND Connect to HV Use AWG 2...

Page 11: ...source Connect in between VIN1 VIN2 and GND For example Application current source 4mA to 20mA recommend using 450ohm resistor 7 3 Isolated Analog INPUT Setup The 2CH isolated analog input supports e...

Page 12: ...26 16 The RED wire indicates that it outputs 0V 10V power Connect to VOUT1 or VOUT2 Use AWG 26 16 The BLACK wire indicates that it comes external GND Connect to GND 7 4 Isolated Analog OUTPUT Setup T...

Page 13: ...l state Device termination is ON Device Status LED Color Flashing Frequency Description Unconfigured device YELLOW LED flashing 1Hz Unconfigured device with factory default address 126 Configured devi...

Page 14: ...No BRTSYS 005 Copyright BRT Systems Pte Ltd 14 9 Mechanical Dimension Figure 7 LDSBus Isolated IO Controller Dimension Top View Figure 8 LDSBus Isolated IO Controller Dimension Side View Figure 9 LDS...

Page 15: ...application descriptions suggested BRT Systems devices and other materials is provided for reference only While BRT Systems has taken care to assure it is accurate this information is subject to custo...

Page 16: ...right BRT Systems Pte Ltd 16 Appendix A References Document References BRTSYS_AN_001_LDSBus_Configuration_Utility_User_Guide Acronyms and Abbreviations Terms Description AC Alternating Current AWG Ame...

Page 17: ...tatus LED Indicator 13 List of Figures Figure 1 LDSBus Isolated IO Controller 5 Figure 2 LDSBus Isolated IO controller Connection Diagram 6 Figure 3 LDSBus Isolated IO Controller Flush Mount 7 Figure...

Page 18: ...Ltd 18 Appendix C Revision History Document Title LDSBus Isolated IO Controller Datasheet Document Reference No BRTSYS_000009 Clearance No BRTSYS 005 Product Page https brtsys com ldsbus Document Fee...

Reviews: