121
ELECTRICAL AND IGNITION
CONNECTOR SERVICING
6
AMP
Connectors
IMPORTANT:
Always use the appropriate meter
test probes and adapters when testing compo-
nents fitted with these terminals. Electrical grease
is NOT used on
AMP
connectors.
S
UPERSEAL
1.5
Disconnect
Lift latch. Pull connectors apart.
Connect
Confirm the seal is in place. Push connectors
together until latched.
Terminal Removal
Use Secondary Lock Tool, P/N 777078, to release
anti-backout device of connector housing. Next,
use Primary Lock Tool, P/N 777077, to release
locking tab of connector housing. Release locking
tab and pull on wire to remove from connector
housing.
Terminal Installation
Align terminal with connector housing. Push con-
nector and seal into housing until seated.
Align anti-backout device with connector housing
and terminals. Use Secondary Lock Installer,
P/N 777079, to seat device in connector.
Crimping Terminals
Crimping
Superseal 1.5
terminals requires
AMP
Crimp Tool with dies, P/N 777281.
1.
Latch
2.
Seal
002448
1.
Anti backout device, plug
2.
Anti backout device, receptacle
002449
002450
2
1
2
1
1.
Locking tab, plug
2.
Locking tab, receptacle
002447
1.
Terminal and seal
002451
1.
Terminal
2.
Seal
002452
2
1
1
1
2
Summary of Contents for EVINRUDE E-TEC BE50DPLABA
Page 228: ...228 POWERHEAD POWERHEAD VIEWS 2 Cylinder Front 008160...
Page 229: ...229 POWERHEAD POWERHEAD VIEWS 10 2 Cylinder Rear 008161...
Page 230: ...230 POWERHEAD POWERHEAD VIEWS 2 Cylinder Top 008162...
Page 231: ...POWERHEAD POWERHEAD VIEWS 231 10 2 Cylinder Top Rope Start Models 008186...
Page 234: ...234 POWERHEAD POWERHEAD VIEWS 3 Cylinder Front 008166...
Page 235: ...235 POWERHEAD POWERHEAD VIEWS 10 3 Cylinder Rear 008167...
Page 236: ...236 POWERHEAD POWERHEAD VIEWS 3 Cylinder Top 008165...
Page 374: ...S 2...
Page 416: ......