4.7.14 Enter
Those familiar with ASCII code can enter commands manually in the Enter box. See Chapter 5 for more
information about communicating directly with the Myriad, including a list of ASCII commands.
Chapter 5. Operations: Direct Communication Mode
5.1 Introduction
Users may communicate directly with the Myriad via the virtual serial port using ASCII command strings.
Multiple Myriads can be networked and controlled from a single terminal. Skilled users may incorporate
Myriad communication into their own programs or databases by utilizing the associated ASCII commands.
5.2 Communication and Command Protocol
Command:
“cmd –M\r”
Mute On
Response:
“OK\n\r”
Command:
“cmd –m\r”
Mute Off
Response:
“OK\n\r”
Command:
“cmd –V\r”
Smart Volume On
Response:
“OK\n\r”
Command:
“cmd –v\r”
Smart Volume Off (Direct Mode)
Response:
“OK\n\r”
Command:
“cmd –R\r”
POT inactive
Response:
“OK\n\r”