BASE DIMENSIONS
4
If the float should catch on any part of the waterer, its lateral position can be changed by loosening the large as-
sembly nut (VP15) and turning the valve body slightly. If float is rubbing on the insulation in the valve cover you
can trim the insulation with an ordinary knife.
VALVE ADJUSTMENT: All Brower pressure waterers are equipped with valves with interchangeable orifices when
shipped. This dependable valve has served our customers since 1975. The standard valve for your unit normally
operates on a range of 20 to 60 psi. When your waterer is installed on a gravity flow or low pressure system, you
may adjust your valves for more water volume by using a larger orifice in the valve. If your waterer is installed on a
high pressure water system (over 60 pounds) you may compensate for extra pressure by using a smaller orifice in
the valve. For severe high pressure situations, you may need to install a pressure regulator.
See EXHIBITS E & F for valve repair parts. Table 1 shows valve capacities in gallons per minute at various pres-
sures.
7
EXHIBIT B
EXHIBIT C
EXHIBIT D